China Rtd PT100 4-20mA Temperature Sensor Temperature Thermometer, Find details about China Temperature Transducer, Temperature Transmitter from Rtd PT100 4-20mA Temperature Sensor Temperature Thermometer
Measuring media | liquid, gas and steam | ||
Measuring range | -270~800 ºC (PT100 thermal resistor) | ||
0~1300ºC, (Thermocouple K) | |||
Input | Thermocouple, RTD, MV, Resistive sensor | ||
Power supply range | 9~45V (9~24V, Ex) | ||
Output signal | 4~20mA/Hart/Profibus PA | ||
Digital Accuracy | ±0.01ºC, PT100 input | ||
Internal cold end compensation error | <0.25ºC±0.1%/10ºC | ||
Temperature drift | ±0.05%/10ºCfull scale range | ||
0.1% between-10°C to 60°C | |||
Effect of power supply on range | <0.005%/V full-scale range | ||
Long term drift | <0.1/year | ||
Ambient temperature | Ambient temperature | Storage temperature | |
T4 | Safe operation(T6) | ||
-40...85ºC | -40...60ºC | -40...95ºC | |
Protection Class | IP66/67 | ||
Relative humidity | ≤98%, condensation allowed | ||
Electromagnetic compatibility | Accordance with EN 61 326 |
Model | Product details | ||
WNK6T | Smart temperature transmitter | ||
Code | Approvals | ||
A | For non explosion-proof areas | ||
1 | ATEX II 1/2G EExia II CT6 | ||
2 | ATEX II 1/2G EExia II CT6,overflow protection WHG | ||
3 | ATEX II 1/2D | ||
4 | ATEX II 1/3GD EExia II CT6 | ||
5 | ATEX II 1/3D | ||
6 | ATEX II 2G EEx d II T6 | ||
7 | ATEX II 3G EEx nA II CT6 | ||
For other approvals or more information, please contact with us | |||
Code | Communication, Display, Operation | ||
A | 4...20mA HART,LCD,operation outside | ||
B | 4...20mA HART,LCD,operation inside | ||
C | 4...20mA HART | ||
M | PROFIBUS PA,LCD,operation outside | ||
N | PROFIBUS PA,LCD,operation inside | ||
O | PROFIBUS PA | ||
P | FF,LCD,operation outside | ||
Q | FF,LCD,operation inside | ||
R | FF | ||
Code | Housing; Cable entry; Protection | ||
A | Aluminum14,M20×1.5,IP66/67/NEMA 6P | ||
B | Aluminum14,G1/2,IP66/67/NEMA 6P | ||
C | Aluminum14,1/2NPT,IP66/67/NEMA 6P | ||
Code | Type of the transmitter connecting with sensor | ||
X1 | Integral type | ||
X2 | Split type | ||
For integral type, it need to choose the connection additional option | |||
Code | Input type, Measurement range | Code | Input type, Measurement range |
OA | Ohm,0~100Ω | RA | Thermocouple ,S |
OB | Ohm,0~260Ω | RB | Thermocouple,R |
OC | Ohm,0~390Ω | RC | Thermocouple,B |
OD | Ohm,0~3900Ω | RD | Thermocouple,K |
OE | Ohm,PT100 | RE | Thermocouple,N |
OF | Ohm,PT1000 | RF | Thermocouple,E |
OG | Ohm,CU50 | RG | Thermocouple,J |
OH | Ohm,CU100 | RH | Thermocouple,T |
DA | Voltage,-20~20mV | ||
DB | Voltage,-50~50mV | ||
DC | Voltage,-75~75mV | ||
DD | Voltage,-750~750mV | ||
Code | Standardization,unit | ||
1 | Standardization:rated range,°C | ||
2 | Standardization:rated range,°F | ||
3 | Standardization:rated range,°R | ||
Code | Option | ||
A | No | ||
M | Mounting bracket for wall | ||
U | Mounting bracket for pipe | ||
Code | Additional option for intergral type(interface: transmitter to sensor) | ||
F1 | M10×1 | F4 | M20×1.5 |
F2 | M12×1 | F5 | M24×1.5 |
F3 | M18×1.5 | F6 | Per customer requirement |
Typical model#: WNK6T AAA X2RD 1U |
Why Choose us?
1. We are professional manufacturer with own R&D and sales team, with more than 13 years producing experience in transmitters & sensors.
2. We have strict quality control system, each set product we do temperature compensation and aging test before shipment, so the quality is guaranteed.