China Substitution for 1A Secondary Current Transformer of Converter Integrating and Amplifing Rogowski Coil Mv Signal to Standard Current or Voltage Signals, Find details about China 1A Three Phase Analog Signal Integrator, Rogowski Coil Flexible Sensor 1A Integrator from Substitution for 1A Secondary Current Transformer of Converter Integrating and Amplifing Rogowski Coil Mv Signal to Standard Current or Voltage Signals
Advantage • High read accuracy 0.5% • Compact DIN-RAIL construction • High bandwidth for measurement 30 to 5kHz • Output 1A rms Related Products Y-FCT,FCT,NRC,MRC | Applications Measuring devices, lab instrumentation • Power monitoring & analysis • Harmonics and transients monitoring • Welding machine control • High current measurement |
Model | ATP-01 |
Rated output | 1A AC rms |
Maximum Output(overload) | 1.5A AC rms |
Rated ratio | 100A 600A 1000A 3000A 6000A |
Read Accuracy | 0.5% typical at 1%(≥10A) to 110% of rated Current @25ºC |
Phase error | ≤0.5° |
Linearity | ±0.2% of reading(10% to 120% of range) |
Bandwidth | 30Hz to 5kHz |
Maximum Burden | 0.5Ω(each phase) |
Measurement | Secondary CTs to measure output of integrator |
Power consumption | 10W |
Output on 0A (zero drift) | ≤0.01A |
Temperature drift | 200ppm/ºC |
Weight | 185g |
Dimension | 114*100*22.5mm |
Power supply | 12V DC |
Operating temperature | -20ºC to 50ºC |
Storage temperature | -30ºC to 70ºC |
Relative humidity | 80% max.without condensation |
Protection degree | IP20 |
Other requirements, please contact us to OEM. |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. | Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) | ||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) | Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% | |
Code:SRC | Code:50 Code:100 Code:150 | Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | |
Other requirement could be OEM |
Integrator | Output form | Output value | Rated current | Power supply |
Code:D1 (DIN-RAIL integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -5(5V) | Code: -600A Code: -1kA Code: -3kA Code: -6kA | Code: -12(12V DC) Code: -24(24V DC) |
Code: .3(4-20mA output) | N/A | |||
Code:S9 (mini integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -3(3V) | Code: -12(6-12V DC) Code: -24(24V DC) | |
Code:S1 (high accuracy integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -5(5V) Code: -10(10V) | Code: -12(4-12V DC) Code: -24(24V DC) | |
Code: .3(4-20mA output) | N/A | |||
Code:ATP-01 (1A output three phase integrator) | N/A(0-1A) | N/A | Code: -12(12V DC) Code: -24(24V DC) | |
Code:A01 (1A output integrator) | N/A(0-1A) | N/A | N/A(85-265V AC DC) | |
Code:A05 (5A output integrator) | N/A(0-5A) | N/A | N/A(85-265V AC DC) | |
Code:HF (high frequency integrator) | N/A(0-10VAC peak) | N/A | Code: -1kA(1kA/1V) Code: -10kA(10kA/1V) | N/A(4-12V DC) |
Other requirement could be OEM |