SpecificationsPacking Detail: 2440*1100*1420mm, 3.9 CBM . NW: 353KG, GW:538KG. Specifications | 1.Fluoroscopic Capacity Max rated capacity : Tube Current 4mA, Tube Voltage 120kV Automatic Fluoroscopy : Tube Voltage:40kV~120kV Adjust Automatically Tube Current : 0.3mA~4mA Manually Settings Manual Fluoroscopy : Continuous Tube Voltage:40kV~120kV Continuous Tube Current : 0.3mA~4mA Pulse Fluoroscopy : Continuous Tube Voltage 40kV~120kV Continuous Tube Current 0.3mA~30mA 2. Photography Capacity Max rated capacity : 5 KW Tube Voltage and Current Combination : 40kV~49kV 1 ~180 mAs 50kV~59kV 1 ~140 mAs 60kV~69kV 1 ~125 mAs 70kV~79kV 1 ~110 mAs 80kV~89kV 1 ~100 mAs 90kV~99kV 1 ~80 mAs 100kV~109kV 1 ~63 mAs 110kV~120kV 1 ~50 mAs Plate holder Size : 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) 3. X-ray Tube X-ray Tube Special for High Frequency Fixed anode Dual-focus: large focus: 1.5, small focus: 0.3mm*0.3mm (Advantage) Inverter Frequency : 40KHz Thermal capacity : 35KJ (47KHU) 4.Video System Image Intensifier : Image Intensifier made by TOSHIBA (9″) CCD Vidicon : Ultra low-light CCD camera imported from Japan Monitor : Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 75 CCU(central control) : Recursive Filter: K=8,8 images storage, image upright, image overturn, positive & negative image;LIH(last Image Hold) and OSD(monitor display) 5.Structure: Directive wheel : ±90°revolution,can freely change the moving direction of the unit . Ascending & Descending Range of Pillar : ≥400mm C-arm : Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis : ±15°( Advantage), better than others' ±12.5°, easier to take special positions radiography ) Slip on orbit: 120°(+90°~ -30°)
| Features 1,With a compact appearance, and easy to operate; 2,Clinical Video system with high performance,8 images storage volume, and two 14high-resolution monitors; 3,Automatically track fluoroscopy to make the image brightness and clearness optimum; 4,Automatically store the last image of fluoroscopy to advantage diagnosis; 5,With a high-quality knockdown X-ray generator to reduce radiation | IUsage: Orthopaedics:osteopathy, diaplasis, nailing Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work. IIFeatures 1, With a compact appearance, and easy to operate 2, Unique base electric auxiliary support arm design, it's more security for using. 3, A unique hand-held controller design, convenient to operate 4, With a high-quality knockdown X-ray generator to reduce radiation 5, With the Perspective KV,MA automatically track fluoroscopy to make the image brightness and clearness optimum 6, Toshiba image intensifier, the quality is stable and reliable, a good image clarity 7, Clinical Video system with high performance,8 images storage volume, and two 14high-resolution monitors 8, Installation of dense grain grids, to further enhance image sharpness IIIConfiguration 1, New (with electric auxiliary support arm) C-arm host one set 2, High-frequency high-voltage X-ray generator and high-frequency inverter power supply(5.0KW,40KHZ,120KV) one set 3, Toshiba 9-inch image intensifier one set 4, Imports of super-low-light digital camera one set 5,CCU in the high-definition progressive output control system one set 6,Dense grain grids one set 7,Electric adjustable speed limiter one set 8,14-inch CRT monitor private medical one set 9, 19 inch LCD display one set 10, Single use hand-held controller one set 11, Digital work station with thermal printer one set IV Performance and Parameter Category | Project | Content | Fluoroscopic Capacity | Photography Max rated capacity | 5.0KW | Fluoroscopic ax rated capacity | Tube Current 4mA, Tube Voltage 120kV | Automatic Fluoroscopy | Tube Voltage:40kV~120kV adjust automatically Tube Current:0.3mA~4mA adjust automatically | Manual Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:0.3mA~4mA Continuous | Pulse Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:0.3mA~30mA Continuous | Photography Tube Voltage and mA | 40 kV~120 kV 20-100mA | Plate holder Size | 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) | X-ray Tube | X-ray Tube Special for High Frequency | Fixed anode Dual-focus, small focus: 0.3, Inverter Frequency: 40KHz | Video System | Image Intensifier | Image Intensifier made by TOSHIBA (9″) | CCD Video camera | 1 Mega Ultra low-light CCD camera imported | Monitor | 14" VGA and 19" LCD monitor | CCU(central control) | Recursive Filter: K=8, 8 images storage, image upright, image overturn,positive & negative image;LIH(last image freeze, and OSD(monitor display) | Structural performance | Directive wheel | ±90°revolution,can freely change the moving direction of the unit. | Ascending & Descend | ≥400mm | C-arm | Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis : ±15° Focus screen distance:960mm C-arm opening: 760mm C-arm arc depth: 640mm Slip on orbit: 120°(+90°~ -30°) |
|