Gfuve IP67 Waterproof Outdoor Split-Core CT 200/5A 2.5va 0.5s for Distribution Transformer Monitoring

China Gfuve IP67 Waterproof Outdoor Split-Core CT 200/5A 2.5va 0.5s for Distribution Transformer Monitoring, Find details about China Split-Core CT, Split-Core Current Transformer from Gfuve IP67 Waterproof Outdoor Split-Core CT 200/5A 2.5va 0.5s for Distribution Transformer Monitoring

Model NO.
LZCK-55 200/5a 0.5s
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Names
IP67 Waterproof Outdoor Split-Core CT 0.5s
Ratio
200/5A
Burden
2.5va-5va
Color
Orange or Black
Applications
Distribution Transformer Monitoring
Installation Postion
outdoor Use
Class
0.5s, 0.5, 1
Weight
2.5kg
Waterproof
IP67
Frequency
40-2kHz
Trademark
GFUVE
Transport Package
Standard Wooden Box
Specification
200/5a 0.5s
Origin
Beijing China
Model NO.
LZCK-55 200/5a 0.5s
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Names
IP67 Waterproof Outdoor Split-Core CT 0.5s
Ratio
200/5A
Burden
2.5va-5va
Color
Orange or Black
Applications
Distribution Transformer Monitoring
Installation Postion
outdoor Use
Class
0.5s, 0.5, 1
Weight
2.5kg
Waterproof
IP67
Frequency
40-2kHz
Trademark
GFUVE
Transport Package
Standard Wooden Box
Specification
200/5a 0.5s
Origin
Beijing China
Package size per unit product
33.00cm * 30.00cm * 27.00cm
Gross weight per unit product
8.500kg
LZCK-55 GFUVE IP67 waterproof outdoor split-core ct 200/5a 2.5va 0.5s for Distribution transformer monitoring

LZCK-55 OUTDOOR OPEN-TYPE split-core ct. In generally, Outdoor Split-core CT which is being used for distribution transformer monitoring, is designed to fulfill IP67 standard. However, these current sensors are vulnerable to the external circumstances such as UV, rain, wind, vibration and lightning surge. LZCK-55 split-core ct is high precision split core current transformer 0.5s. Many LZCK-55 are used by electric power company in metrological service and energy consumption monitoring department. its standard are according in IEC60044-1, IEC 61869-2, NTC 2205, GB1208-2006 and ANSI C57.13.

APPLICATION
Distribution transformer monitoring;
current measurement;
Split core current transformer;
Split core current sensor;
Harmonics monitoring;
current Load analyzer;

 

SELECTION GUIDE

 ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PC IP67
LMCK185-10300-3000A≤25VAφ185350×283×554.5PC IP67
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)
 

PARAMETERS

Technical parameters
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1000A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.

Photo
Gfuve IP67 Waterproof Outdoor Split-Core CT 200/5A 2.5va 0.5s for Distribution Transformer Monitoring