Type | Function | Note |
Blank | Io and Vo fixed.(For harsh environment) | By request |
A | Io adjustable via built-in potentiometer | In Stock |
AB | Io adjustable via built-in potentiometer + 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) | In Stock |
MODEL | XLG-150-12 | XLG-150-24 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | ||
CONSTANT CURRENT REGION Note.2 | 8.4~ 12V | 16.8~ 24V | |||
RATED CURRENT | 12.5A | 6.25A | |||
RATED POWER | 150W | 150W | |||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 240mVp-p | |||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) | ||||
6.5~ 12.5A | 3.2~ 6.25A | ||||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±2% | ±1% | |||
SETUP, RISE TIME Note.6 | 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC | ||||
INPUT | VOLTAGE RANGE | Note.5 | 100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) | ||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF>=0.97/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC@full load | ||||
TOTAL HARMONIC DISTORTION | THD< 10%(@load>=50%/115VC,230VAC; @load>=75%/277VAC) | ||||
EFFICIENCY (Typ.) | 91.5% | 93% | |||
AC CURRENT | 1.8A / 115VAC | 1.0A / 230VAC 0.8A/277VAC | |||
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=500μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD POWER CONSUMPTION | No load power consumption <0.5W for A-Type | ||||
PROTECTION | OVER CURRENT | 95 ~ 108% | |||
Constant current limiting, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 13.5 ~ 18V | 27 ~ 34V | |||
Shut down output voltage, re-power on to recover | |||||
INPUT OVER VOLTAGE Note.7 | 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage) | ||||
can survive input voltage stress of 440Vac for 48 hours | |||||
OVER TEMPERATURE | Shut down output voltage, recovers automatically after fault condition is removed | ||||
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90ºC (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) | |||
MAX. CASE TEMP. | Tcase=+90ºC | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +90ºC, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.06%/ºC (0 ~ 60ºC) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
SAFETY & EMC | SAFETY STANDARDS | UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14; EAC TP TC 004; IP67 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:4.2KVAC | I/P-FG:2.1KVAC O/P-FG:1.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | ||||
EMC EMISSION | Compliance to EN55015,EN61000-3-2 Class C (@load>=50%) ; EN61000-3-3; | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)(10K/6KV option) | ||||
OTHERS | MTBF | K hrs min. | Telcordia SR-332 (Bellcore) ; Khrs min. | MIL-HDBK-217F (25ºC) | |
DIMENSION | 180*63*35.5mm (L*W*H) | ||||
PACKING | 0.8Kg;16pcs / 13.4Kg /0.67CUFT | ||||
NOTE |
|