0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield

China 0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield, Find details about China Extension Cable, Thermocouple Cable from 0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield

Model NO.
TX 0.5*2
Material Shape
Flat Wire
Range of Application
Temperture Measurement
Certification
CCC, RoHS
Brand
Ohmalloy/OEM
Product Name
Type T Extension Cable
Jacket Material
PVC
Color Code
ANSI
Cunstomized Service
Color, Insulation,Package
MOQ for Customize
500 Meter
Application Way
Thermocouple Extension Cable
Trademark
Ohmalloy/OEM
Transport Package
Coil+ Waterproof Paper+ Wooden Case
Specification
0.5mm*2
Origin
China
HS Code
9025900090
Model NO.
TX 0.5*2
Material Shape
Flat Wire
Range of Application
Temperture Measurement
Certification
CCC, RoHS
Brand
Ohmalloy/OEM
Product Name
Type T Extension Cable
Jacket Material
PVC
Color Code
ANSI
Cunstomized Service
Color, Insulation,Package
MOQ for Customize
500 Meter
Application Way
Thermocouple Extension Cable
Trademark
Ohmalloy/OEM
Transport Package
Coil+ Waterproof Paper+ Wooden Case
Specification
0.5mm*2
Origin
China
HS Code
9025900090
Package size per unit product
40.00cm * 40.00cm * 20.00cm
Gross weight per unit product
10.000kg

0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield

 

Conductor specification

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures.

1. Chemical Composition

MaterialChemical composition (%)
NiCuSiIronAl
TP(Copper) 100   
TN(Constantan)4555   

2. Physical Properties and Mechnical Properties

 

 

Material

 

 

Density(g/cm3)

 

Melting point(ºC)

 

Tensile Strength(Mpa)

 

Volume resistivity(μΩ.cm)

 

Elongation rate (%)

TP(Copper)8.91084>1961.71(20ºC)>30
TN(Constantan)8.81220>39049.0(20ºC)>25




In actual temperature measurement, usually there are long measuring distance with the measuring device, a thermocouple compensation wire is generated to compensate the temperature difference caused by the temperature change between the measuring device and the thermocouple connecting piece.

 

The compensation cable has the following advantages: improving thermocouple temperature measurement line physical properties and mechanical properties; improving the measurement line flexibility and making the connection convenient by using multi-strand core or small-diameter compensation wire; easy to shield external interference; reducing measuring lines cost.

 

Thermocouple Cable Grade

A:Extension Grade Cable

Whose wire composition is totally as the same as the thermocouple wire, remarked by the letter"X"after the thermocouple symbol number, such as"KX""JX""TX"

B:Compensation Grade Cable

Whose wire composition is different from the thermocouple wire, but its wire electromotive force (EMF) value is the same as thermocouple wire only at 0-100ºC or 0-200ºC. It remarked by the letter"C"after the thermocouple symbol number, such as"KC""JC""TC"

  1. For cost consideration, when the tested temperature under 200ºC, compensation grade cable is preferred. But compensation grade cable will occur enormous tested temperature value deviation if the tested temperature above 200ºC. The higher the tested temperature, the greater deviation be.
  2. For compensation grade cable, the max testing temperature is less than 200ºC, the bigger the cable, the smaller the signal loss.
  3. Extension cable and compensation cable comparison:

 

    Performance

Extension GradeCompensation Grade

Material

Same as thermocoupleDifferent from thermocouple
EMF Value FeatureSame as the thermocouple's at certain temperature rangeSame as the thermocouple's
Deviation CurveNonlinear, varies with temperature

  Linear

Working Temperature RangeLimited(usual at 100ºC)Unlimited(depend on insulation material temperature bearing)
Line ResistanceLow resistanceHigh resistance
Compensation Contact InterferenceDifferent contactor material may cause interference

None

Accuracy

Low

High

Price

Low

High(about 1-2 times higher)

0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield
 

2. Size Range Reference
0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield

 

3.  Package Reference

0.5mm*2 PVC Insulated Type T Extension Cable with Ss Shield
 

5.  Questions and Answers

 

Q1:How can I contact with your company?

A1:We have multiple communication channels    

 

Q2:Do you provide free samples?

A2:Yes,we can provide free samples for your testing,but buyer should bear the shipping costs.

 

Q3:What is your payment terms?

A3:30% in advance,balance after receiving the copy of B/L. T/T,L/C,Western Union,Paypal is OK.

 

Q4:What is your lead time?

A4:On normal condition,the lead time is 7 days after the payment. Special order or quantity is subject to the negotiation.

 

Q5:What is your working time?

A5: Monday to Firday: 9:00-12:00,13:30-17:30, rest in weekend.