Diesel Kerosene Gasoline Ogm Electronic Gear Flowmeter

China Diesel Kerosene Gasoline Ogm Electronic Gear Flowmeter, Find details about China Fuel Meter from Diesel Kerosene Gasoline Ogm Electronic Gear Flowmeter

Model NO.
OGM-dn25
Application
Energy Metering
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Trademark
guan xiang
Origin
China
Model NO.
OGM-dn25
Application
Energy Metering
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Trademark
guan xiang
Origin
China
Diesel Kerosene Gasoline Ogm Electronic Gear FlowmeterDiesel Kerosene Gasoline Ogm Electronic Gear FlowmeterDiesel Kerosene Gasoline Ogm Electronic Gear FlowmeterIntroduction
 
OGM-25/40/50 aluminum oval gear meter has the ability to handle a wide range of fluid viscosities with execptional levels of repeatability and durability .applying in the petroleum,chemical,food industry etc.and it has big advantages as follows.
 
Characteristic
 
1.low pressure drop
2.Compact sixe,easy maintenance
3.Easy to read and operate mechanical display
4.Horizontally and vertically fiexibility of installation options
5.5-digital sub-total,with floating point from 0.01 to 9999.99,7-digital non-resettable totalizer
6.3.6V lithium battery power,durable service.

Technical Specification
ModelOGM-25OGM-40OGM-50
Size1"1.5"2"
Flow Rate20-200L/min25-250L/min30-300L/min
Accuracy±0.5%±0.5%±0.5%
Max pressure3.4Mpa1.8Mpa1.8Mpa
Ports1"BSPT1.5"BSPT2"BSPT
Register/talizer4 Digital/6 Digital
UnitLiter/US Gallon/MP Gallon
 
OGM pulsed oval gear meter
 
Characteristic
 
Oval gear meter disign low maintenance.low pressure drop.5V DC power supply required. Reading in litres.
 
Technical Specification
ModelOGM25-DPOGM40-DPOGM50-DP
Size1"1.5"2"
Flow Rate20-200L/min25-250L/min30-300L/min
Accuracy±0.5%±0.5%±0.5%
Max pressure3.4Mpa1.8Mpa1.8Mpa
Ports1"BSPT1.5"BSPT2"BSPT
Register/talizer4 Digital/6 Digital
UnitLiter/US Gallon/MP Gallon
 
 
Button operation instructions
 
1. Power on: When the START button is turned on, or the sensor has a metering pulse signal, the flow meter automatically shuts down for 1 minute without any operation.
2. Single data clear: Press the CLEAR button in the normal display state to clear the single fueling data.
3. View total accumulation: Press the TOTAL button for 5 seconds in the normal display state. At this time, the TOTAL word appears on the next line. The total display is the total accumulation after 3 seconds.
4. Single cumulative clearing: Press the TOTAL button for 5 seconds in the normal display state, the total cumulative display, press the TOTAL button, the single cumulative flashing, press the CLEAR button to clear the single accumulation.


The working principle of the elliptical gear flowmeter
 1. The flowmeter is installed at the oil outlet end of the oil pump. If it is installed at the oil inlet, the pressure of the filter is damaged, so that the negative pressure of the oil pump is increased, so that the flow meter is not accurately measured, and the inlet and outlet of the pump also need to be completely sealed. Otherwise, the flow meter will be metered inaccurately.
2. Install a filter at the front end of the flowmeter to prevent particles larger than 0.2MM from passing through, in order to prevent the flowmeter from getting stuck or blocked due to the particle surface. The filter should be cleaned frequently.
3. The check valve should be equipped with a check valve to prevent the pipe liquid from flowing in one direction, preventing the meter gear from being reversed, or idling to make the flow meter measurement inaccurate.
4. The flowmeter should be properly installed. The display screen of the flowmeter should be installed upwards or at 90 degrees, and it should not be installed diagonally.
5. The flowmeter should be installed in the same direction as the direction of the liquid shown on the flowmeter housing. The installation position should be convenient for reading.
6. The flowmeter pressure loss is proportional to the liquid flow rate, the liquid viscosity increases, and the pressure loss also increases.
 
Error coefficient calibration
    In the standby state or the current fill amount display state, press the START button for 5 seconds to enter the error coefficient calibration state. The middle row is displayed in front of E- and the last digit is flashing. Press START button, digital shift, (blinking digital shift), press CLEAR button for "plus", press TOTAL button for "minus" to modify the current flashing digit value. . When this coefficient is increased, the amount of oil is reduced, and the smaller the coefficient, the more oil is produced. Standby for 5 seconds to end the error factor calibration. Return to display the current fill amount status. After the error coefficient is calibrated, if there is a new metering pulse input, the new error coefficient is used for calibration. The error coefficient calibration range is 0000-20000. Each time a coefficient is adjusted, the error of the flow meter adding oil is about 0.05%
 
Unit of measure setting
In the standby state or the current fill amount display state, press the START button for 5 seconds. Enter the error coefficient calibration state, press the START button 4 times to enter the unit conversion, the screen displays UN 4, press the CLEAR or TOTAL button, select cubic meters / M3 → US gallons / US → gallons / GA → l / L → kg / KG measurement The unit and the cumulative amount of the added amount are displayed after being converted according to the current unit of measure. Press the START button 2 times or standby for 5 seconds to exit the unit conversion setting.