Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece

China Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece, Find details about China Dental, Dental Handpiece from Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece

Model NO.
CEN-02C
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Exhaust Outside
Number of Holes
Four Holes
Connection
Without Quick Connector
Rotating Speed
Low-Speed Handpiece
Noise
Less Than 70dB
Gear Ratio
1:1
Trademark
TEALTH
Transport Package
Plastic Box
Specification
Aluminum, stainless steel
Origin
China
HS Code
90184100
Model NO.
CEN-02C
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Exhaust Outside
Number of Holes
Four Holes
Connection
Without Quick Connector
Rotating Speed
Low-Speed Handpiece
Noise
Less Than 70dB
Gear Ratio
1:1
Trademark
TEALTH
Transport Package
Plastic Box
Specification
Aluminum, stainless steel
Origin
China
HS Code
90184100
Name: External irrigation push button 1:1 contra angle 
Model : CEN-01C

Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece
Packing List: 
- Push Button Contra Angle handpiece: 1 pcs 
- Cap Spanner: 1 pcs 
- English manual: 1 pcs 

Features:
1.Ratio: E-type Low Speed Handpiece 1:1 Ratio, with external water Cooling System
3. Air Pressure: 245-392Kpa (2.5-4.0 kgf/cm²)
4. Water Pressure: 200Kpa (2kg)
5. Rotation Speed: 14,000-20,000 rpm
6. Chuck Type: Press button
7. Bur Applicable: Φ2.334-2.355mm (CA BUR CONTRA ANGLE & HP BUR STRAIGHT CONE)
8. Noise: ≤65dB

Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece
Handpiece inserting & removal
Inserting
Insert the E-type handpiece onto the motor and turning all the way until it click to stop.

Removal
Grip both handpiece and motor respectively, pulling and separating.
Tealth 1: 1 Contra Angle External Irrigation Dental Handpiece
Maintenance & Care
After each treatment, sterilizing handpiece in autoclave according to the following steps:
1. Remove the bur, use brush to clean handpiece, then cleaning outside of handpiece with alcohol solution.
2. Lubricate handpiece.
3. Package into autoclaving pouch.
4. Autoclave the handpiece for 12 min at 135ºC.
5. Dental handpieces cannot be soaked in a disinfectant with acidic liquid. it will seriously damage the bearings and handpiece internal components
6. Do not use an ultrasonic cleaner to clean the dental handpiece.
7. It is not recommended to repair the dental handpiece by little experience person. For repairing, please return to the factory or send to the designated after-sales service maintenance office.