Transformer Winding Distortion Analyzer Short Circuit Impedance Tester

China Transformer Winding Distortion Analyzer Short Circuit Impedance Tester, Find details about China Transformer Winding Analyzer, Transformer Winding Distortion Analyzer from Transformer Winding Distortion Analyzer Short Circuit Impedance Tester

Model NO.
GDZT-3A
Testing accuracy
Voltage/current: 0.2%
Voltage range
AC 3V-300V
Internal power output range
Voltage 0-250V, Current 0-10A
Current range
AC 0.2A-20A
Working temperature
-10ºC~50ºC
Working humidity
0-80%
Powr supply
AC220V±10%, 50Hz±1Hz
Trademark
HV HIPOT
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan, China
Model NO.
GDZT-3A
Testing accuracy
Voltage/current: 0.2%
Voltage range
AC 3V-300V
Internal power output range
Voltage 0-250V, Current 0-10A
Current range
AC 0.2A-20A
Working temperature
-10ºC~50ºC
Working humidity
0-80%
Powr supply
AC220V±10%, 50Hz±1Hz
Trademark
HV HIPOT
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan, China

Transformer Winding Distortion Analyzer Short Circuit Impedance Tester

Transformer Winding Distortion Analyzer Short Circuit Impedance Tester


Product Description

Low-voltage short-circuit impedance measurement is basic subject in routine test. Comparing the short-circuit impedance value of transformers before and after short-current impact, to estimate winding distortion degree according to variable value. The changes of transformer impedance should not be over 2%.

LV short circuit impedance test is the most direct way to check winding distortion when the transformers are impacted by short circuit current or mechanic shocked by transportation and installation. It is useful to judge if the transformers can be put into operation.


Features
  • With adjustable power output. No matter single phase or 3-phase transformers, the instrument could finish test for all windings by only one time cable connection.
  • For 3-phase transformers, short-circuit impedance, inductance and reactance of each phase can be obtained automatically after boosting each phase.
  • Using internal phase-locked loop technology, synchronous sampling AC signals, measurement data is accurate.
  • Voltage, current, power, frequency can be measured.
  • Finish load test of transformers. Load loss result at standard temperature will be obtained automatically.
  • Wide current range. Support external CT, PT to expand the measurement range.
  • Data will be stored for long time even power off. Built-in printer to print results.
  • Testing data can be imported into PC for analysis or storage.
  • Menu with operation tips, simple and intuitive.
  • LCD screen, clear to see even in direct sunlight.

Specification
 
Testing accuracyVoltage/current: 0.2%
Power

COSφ>0.1, 0.5%; COSφ≤0.1, 1.0%

Impedance COSφ>0.1, 0.5%; COSφ≤0.1, 1.0%

Voltage range AC 3V-300V
Internal power output rangeVoltage 0-250V, Current 0-10A
Current rangeAC 0.2A-20A
Working temperature -10ºC~50ºC
Working humidity0-80%
Power supplyAC220V±10%, 50Hz±1Hz
Dimensions360mm×220mm×150mm
Weight5kg

Transformer Winding Distortion Analyzer Short Circuit Impedance Tester
Transformer Winding Distortion Analyzer Short Circuit Impedance Tester
Transformer Winding Distortion Analyzer Short Circuit Impedance Tester
Transformer Winding Distortion Analyzer Short Circuit Impedance Tester
Transformer Winding Distortion Analyzer Short Circuit Impedance Tester