China 1 kVA UPS Price Tower and Rack Moun UPS for Server Data Center and ATM, Find details about China Smart UPS, Online Smart UPS from 1 kVA UPS Price Tower and Rack Moun UPS for Server Data Center and ATM
Rack-Tower convertible
Two directions LCD display
Online double conversion (PFC)
Full digital control
Output power factor: 0.9
Economic operation mode (ECO)
Wide input voltage range
Self-testing when UPS startup
Cold start
Multifunctional protection
Output bypass can be set
Input L and N reversed alarm function
Optimized battery configuration(1k:24Vdc, 2k:48Vdc, 3k:72Vdc)
Charger can be extended
Diverse options of accessories, intelligent management
Intelligent slot optional: SNMP/Dry contact card
Technical Specification
MODEL | MEMO RT 1K(S/H) | MEMO RT 2K(S/H) | MEMO RT 3K(S/H) | ||
Capacity (VA/Watts) | 1000/900W | 2000/1800W | 3000/2700W | ||
Phase | Single phase with grounde | ||||
INPUT | |||||
Nominal Voltage | 200/208/220/230/240Vac | ||||
Input Voltage Range | 110~300Vac @ 60% load, 160~300Vac @ 100% load | ||||
Frequency Range | 45~55Hz/55~65Hz (Auto-detect) | ||||
Power Factor | ≥0.99 @Nominal voltage(100% load) | ||||
OUTPUT | |||||
Output Voltage | 200/208/220/230/240Vac | ||||
Power Factor | 0.9 | ||||
Voltage Regulation | ±1% | ||||
Frequency | Synchronized Range | 45~55Hz/56~64Hz | |||
Battery Mode & None Synchronized Range | 50Hz/60Hz±0.1Hz | ||||
Crest Factor | 3:1 | ||||
Harmonic Distortion (THDv) | ≤3% THD (Linear load) ≤6% THD (Non-linear load) | ||||
Transfer Time | AC to DC | Zero | |||
Inverter to bypass | 4ms(Typical) | ||||
Waveform | Pure Sinewave | ||||
EFFICIENCY | |||||
AC Mode | 88% | 89% | 90% | ||
Battery Mode | 83% | 85% | 86% | ||
BATTERY | |||||
Standard model | Battery Type | 12V/9AH | |||
Numbers | 2 | 4 | 6 | ||
Backup time | Estimated remaining time displayed on the LCD | ||||
Typical recharging time | 4 hours recover to 90% capacity | ||||
Charging current(max.) | 1.0A | ||||
Charging voltage | 27.4/41.1Vdc±1% | 54.7Vdc ±1% | 82.1Vdc ±1% | ||
Long run model | Battery numbers | Depending on the capacity of external batteries | |||
Charging current(max.) | 6A/12A (double board) | ||||
Charging voltage | 27.4 ±1% | 54.7Vdc ±1% | 82.1Vdc ±1% | ||
INDICATORS | |||||
LCD | Load level,Battery level,AC mode,Battery mode,Bypass mode,and Fault indicators | ||||
ALARM | |||||
Battery Mode | Beeping every 4 seconds | ||||
Battery Low | Beeping every second | ||||
Overload | Beeping twice every second | ||||
Fault | Continously beeping | ||||
PHYSICAL | |||||
Standard model | Dimension D×W×H (mm) | 380×440×86.5 | 520×440×131 | ||
Net Weight (kg) | 12 | 21.5 | 26 | ||
Long run model | Dimension D×W×H (mm) | 380×440×86.5 | 470×191×336 | ||
Net Weight (kg) | 7 | 11.5 | 11.7 | ||
ENVIRONMENT | |||||
Humidity | 20~90% RH @ 0~40ºC (Non-condensing) | ||||
Noise Level | <50db @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux,FreeBSD and MAC Optional | ||||
Optional SNMP | Power management from SNMP manager and web browser |