China Constant Temperature and Humidity Testing Chamber, Find details about China Environmental High Low Temperature Humidity, Test Chamber Temperature and Humidity from Constant Temperature and Humidity Testing Chamber
Type | Inner size | Shape size |
H/HWHS-50L | 350×350×400mm | 885×850×1320mm |
H/HWHS-100L | 400×500×500mm | 935×1000×1420mm |
H/HWHS-150L | 500×500×600mm | 1035×1000×1520mm |
H/HWHS-225L | 500×600×750mm | 1060×1130×1700mm |
H/HWHS-408L | 600×800×850mm | 1135×1300×1800mm |
H/HWHS-500L | 700×800×900mm | 1235×1300×1850mm |
H/HWHS-800L | 800×1000×1000mm | 1435×1400×1950mm |
H/HWHS-1000L | 1000×1000×1000mm | 1535×1500×1950mm |
Temperature range | Range | -40~160ºC adjustable | |
fluctuation | ≤±0.3ºC | ||
deviation | ≤±2.0ºC | ||
Rate | Heating rate | +25ºC~ +150ºC, ≤40min(No-load nonlinear control) | |
Cooling rate | +25ºC~ -40ºC, ≤60min(No-load nonlinear control) | ||
Change rate | Heating 2ºC~3ºC/Min(No-load nonlinear control) | ||
Cooling 0.7ºC~1.6ºC/Min(No-load nonlinear control) | |||
Inner size | 750mm x 650mm x 450mm(W x L x H) | ||
Ship size | 1060×1130×1700mm(D×W×H) reference only | ||
Power | 220V±10%,50Hz±1 | ||
Heating power | 2KW | ||
Cooling power | 1KW | ||
Total power | 4KW | ||
Structure | Temperature chamber, temperature system. The refrigerating unit is one unit. | ||
Material composition | Outer wall material: cold rolled steel plate electrostatic double-sided spray plastic | ||
Inner wall material: SUS304 stainless steel plate | |||
Thermal insulation material: 120mm glass wool insulation layer | |||
structural strength | Load bearing capacity of test box: ≤50Kg (uniform load) | ||
Door | Single door | ||
Two silicone rubber sealing strips are used for the door frame of low greenhouse | |||
Window | Each door has a multi-layer observation window, and the observation window on the door is coated with heating to prevent condensation and frosting | ||
Condensate outlet hole | It has outlet holes for condensate water in the studio and condensate water in the unit | ||
Overflow hole | An overflow hole is arranged at the rear of the box body to facilitate the outflow of condensed water. | ||
Test hole | One cable hole of 50mm diameter with sealing plug and cover | ||
Control panel | Temperature control display, power switch | ||
Mechanical room | The mechanical room includes: refrigerating unit, connection and drainage device, distribution control cabinet, high and low temperature circulation fan, exhaust fan | ||
Distribution control cabinet | Cooling fan, switchboard, sample test terminals, RS-485 physical interface (optional), main power leakage circuit breaker |