China Phase Sequence Indicator Instrument Wireless Phase Sequence Detector, Find details about China Wireless Phase Sequence Detector, phase sequence detection from Phase Sequence Indicator Instrument Wireless Phase Sequence Detector
GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply can be obtained. There are four strong magnets on the back of the instrument, which can be attached to the distribution box for use.
GDCR1000D non-contact phase tester has the functions of looping inspection, simple power inspection, circuit breaking search, breakpoint location, line maintenance and so on.
Model | Test wire outer diameter |
GDCR1000C | ø1.6mm~ø16mm |
GDCR1000D | ø10mm~ø40mm |
Function | Phase check(positive phase, reverse phase, missing phase), live line check, breakpoint location , line maintenance |
Power supply | DC 3V 2 section alkaline dry cell (LR6), continuous use time of about 70 hours |
Live range | AC 70~1000V, 45~65Hz (sine wave continuous input) |
Test wire size | Outer diameter ø1.6mm~ø16mm or ø10mm~ø40mm(optional) |
LED display | [positive phase] 4 phase detection lights turn on clockwise in turn; [reverse phase] 4 phase detection lights turn on clockwise sequentially. [live line] L1, L2 and L3 lights turn on within the range of voltage setting; [missing phase] L1 or L2 or L3 lights are not on. [open circuit] The L1 or L2 or L3 lights are not on. |
Buzzing | [positive phase] instrument emits intermittent short buzz; [reverse phase] The instrument emits continuous long sounds. |
Battery Indication | POWER indicator lights up after power on; LOW BATTERY lights up when power is insufficient |
Magnetism | There are four magnets attached to the back of the instrument, which are attached to the distribution box and can withstand 800g quality. |
Shut off | After about 5 minutes, the instrument shuts down automatically. |
Dimension | L 70mm* H 75mm* W30mm |
Clamp wire length | 0.6m |
Weight | About 200g (include battery) |
Working condition | -10ºC~55ºC;<80%rh |
Storage condition | -20ºC~60ºC;<90%rh |
Measurement max. voltage | AC 1000V |
Dielectric strength | 5.4kV rms |
Max. rated power | 300mVA |
Standards | EN61010-1:2001, EN61010-031:2002, pollution class 2, CAT III (600V), transient overvoltage 6000V |