Load Capacity
20va
Frequency Output Range
45-65Hz
Harmonic Wave Times
2-31
Weight (Kg)
12
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
440x360x160
Origin
Beijing, China
Model NO.
GF6018A
Customized
Customized
Keyword
Clamp Type Multimeter Calibrator
Model
Multimeter Calibrator
GF6018A
Multimeter Calibrator Clamp Type
Load Capacity
20va
Frequency Output Range
45-65Hz
Harmonic Wave Times
2-31
Weight (Kg)
12
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
440x360x160
Origin
Beijing, China
GF6018A Clamp Type Multimeter Calibrator
The equipment is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

Features
It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error
The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed
Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use
With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management
Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload
GF6018A Clamp Type Multimeter Calibrator
Parameters
Electrical parameters
Power supplySingle phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output
range200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V
Range 20V-1000VAccuracy±(0.03%RD+0.02%FS)
Stability≤0.01% FS /60s
Range 200mV-4000mVAccuracy±(0.3%RD+0.2%FS)
Stability≤0.04% FS /60s
Load capacity20VA
Waveform distortion≤0.3%
Adjustable Range0-120% FS (1000V not included)
Fineness5×10-5
AC Current Output
Range2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A Accuracy±(0.03%RD+0.02%FS)
Stability≤0.01% FS /60s
Range 2mA-40mA  Accuracy±(0.3%RD+0.2%FS)
Stability≤0.04% FS /60s
Load capacity20VA
Waveform distortion≤0.3%
Adjustable Range0-120% FS
Fineness5×10-5
Frequency Output
Range45-65Hz
Fineness0.001Hz
Accuracy0.01Hz
Harmonic Wave
Times2-31
Extent0-20%
Each harmonic phase fineness 0.01·N (N is  harmonic order)
DC voltage output
Range200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V
Load capacity20W
Adjustable range0-110% FS (1000V not included)
Adjustable fineness5×10-5
Stability≤0.01% FS /60s (peak-peak value)
Accuracy±(0.03%RD+0.02%FS)
Ripple wave≤1% FS
DC current output
Range20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Load capacity20W
Adjustable Range0-110% FS (1000V not included)
Adjustable Fineness5×10-5
Stability≤0.01% FS /60s (peak-peak value)
Accuracy±(0.06%RD+0.04%FS)
Ripple wave≤1% FS
Resistance box
Range0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Fineness0.02%
Range 0-2kΩ, 0-20kΩ, 0-200kΩ 
Range 0-2kΩ Adjustable Range0-100%FS
Accuracy±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩAdjustable Range0-100% FS
Accuracy±(0.3%RD+0.2%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ
Range 2kΩ-4kΩAdjustable Range5%-100%FS
Accuracy±(0.12%RD+0.08%FS)
Range  200-400Ω,
2MΩ-4MΩ
Adjustable Range5%-100% FS
Accuracy±(0.3%RD+0.2%FS)
Clamp meter range
200AAccuracy±0.2%
600AAccuracy±0.5%
1000AAccuracy±1%
Dot frequency square wave output
Range1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude4.5V
Setting accuracy5×10-5
Mechanical parameters
Dimension (L×W×H) (mm)440x360x160
Weight (kg)12
Environmental conditions
Operating temperature20°C±10°C
Relative humidity≤85%RH