ABS-YW11 lntegrated two-in-one smoke detector and heat detector testerProduct function overview
- lntegrated two-in-one smoke detector and heat detector tester is a fire detector integrating smoke detector and heat detector. It can carry out a simulated test on the smoke detector and heat detector. It applies to the fire safety inspection, fire safety detection, fire safety maintenance, and fire safety engineering and so on.
- By the principle of detection based on electronic induction, when the top sensor of tester approaches the surrounding ceiling of the detector within 100mm, smoke or heat can be generated to achieve the purpose of the test.
- Electronic atomizing and fuming technology is specially adopted for fuming. The speciallydesigned environmental-friendly liquid for vaporization is free from soot and tobacco tar and will not cause secondary pollution on the detector.
- Electronic energy conversion technology is adopted to rapidly raise the temperature to the alarm threshold of temperature detector within a short time.
Weight | 3.1kg | Standard Length | 2.7m ( Number of connecting rods can be increased ) |
Carton size(mm) | 630×215×100 | External material | Aluminium alloy or PE |
Connecting rod length | 580mm | Material of connecting rod | Anodized aeronautical aluminum |
Instructions
- Charging: lug the dedicated power charger to the power port. After the device is fully charged, the charger indicator lights will change from red to green.
- Absorb liquid for vaporization: Absorb a proper amount of liquid with the injector.
- Disassembly of sealing screw: rotate and remove screw counterclockwise and seal it clockwise. See Drawing 1.
- lnjection of liquid for vaporization: Insert the needle of the injector into the opening and press 5~8 ml. See Drawing 2.
Drawing 1 Drawing 2 5. Observation port of liquid level: Observe the height of liquid with in the liquid level chamber. See Drawing 3
6. Connection: Select the number of connecting rods according to the height and rotate to connect the tester and connecting rods clockwise or dissemble counterclockwise.
7. Intelligent infrared detection: When the top sensor of the tester is close to the ceiling around the detector within 100mm, the instrument will work automatically and generate smoke or heat to achieve the test purpose.
When the top of the instrument is more than 100 mm away from the ceiling, the instrument will automatically stop working. See Drawing 4 Drawing 3 Drawing 38. Function switch: See Drawing 5
- When testing the heat detector, press the button. When the heater and fan are in standby state, the temperature reaches the threshold in 3~5 seconds when the power is on. The distance from the nozzle is 20 mm, and the measured temperature is about 190ºC.
- When testing the Smoke detector, pop up button. The fan and fuming fluid are in standby mode.
9. Lithium battery: Two 18650 Lithium batteries (0.22Ah/pcs). Fully charged battery can detect 450 ~ 800pcs smoke detector.
Drawing 5