1)The Feature of 15 ton precision industrial computer room air conditionera.Application coverage1.Medium and big switch and mobile machine rooms
2.Computer rooms and IDC
3.High-tech environment and labs
4.Industrial control rooms and sophisticated processing equipment.
5.Standard inspection rooms and calibration centers
6.UPS and battery rooms
7.Biochemical incubvators
8.Hosptials and examination rooms
b.High AdaptabilityVarious energy-saving designs
Various air distribution patterns to meet demands from different air flow organizations
Various cooling patterns,including air cooling,water cooling glycol cooling and cold water etc.,benefiting adaptability of on-the -spot conditions
Adapt to different cooling media such as R22,R407c and R410a
Variou supervision patterns
Air cooling condenser offers devices for different temperatures and environments(including start in low temperature)
c.High reliability,high flexibility life cycle costComplete series of products,including models of air cooling ,glycol cooling,wate cooling and cold water
Wide refrigerating range,5kw-100kw for air cooling,water cooling,glycol cooling machines, and 12-151 kw for cold water machines
d.Advantages and CharacteristicsHige reliablity,hing flexibility,life cycle low cost
removable structure for transportation,100% all front maintenance,room space saving
High-efficient scroll comprssor,suitable for invironment-friendly refrigerant
Tension adustment fan, meetin demands from different ext.static pressure
Iarge V-shped evaporator,quick dehumidification design,ensuring energy saving
Unique high-efficient electrode humidification system,quick humidification speed,adapt to bad wate rquality,low maintenance
Ultra big screen and all-chinese character monitor
Strong united control and telecommunicational function
Brand new air cooling speed regulating condenser,low noise.
2)Product modelsmall air cooled precision air conditioner |
model number | total/sensible cooling capacity | electric heating | air flow | air blowing way | external static pressure | cooling power input | fan motor power | noise level | water cooled condenser | humidifier | dimensions |
water cooled | air cooled | water cooled | air cooled | piping connection | water flow | water resistance | capacity | power | width | depth | height |
kw | kw | kw (grade) | m3/h | Pa | kw | kw | kw | dB(A) | m3/h | MPa | kg/h | kw | mm | mm | mm |
JHF5 | -- | 4.85/1.48 | 3(1) | 1420 | upside | 30 | -- | 1.8 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 1750 | -- | 64 | SW-3N |
downside | 30 | 1.8 | 0.18 | ≤50 | 4 | 3.7 | 750 | 500 | 1750 | 64 |
upside(connect blast cap) | 30 | 1.8 | 0.18 | ≤50 | 4 | 3.7 | 750 | 500 | 2000 | 66.5 |
|
JHF6 | -- | 6.29/5.78 | 4.5(1) | 1680 | upside | 30 | -- | 1.8 | 0.18 | ≤51.5 | 4 | 3.7 | 750 | 500 | 1750 | -- | 75 | SW-3N |
downside | 30 | 1.8 | 0.18 | ≤50.5 | 4 | 3.7 | 750 | 500 | 1750 | 75 |
upside(connect blast cap) | 30 | 1.8 | 0.18 | 50.5 | 4 | 3.7 | 750 | 500 | 2000 | 78 |
|
JHF7 | -- | 7.46/6.71 | 4.5(1) | 2200 | upside | 30 | -- | 2.7 | 0.18 | ≤53 | 4 | 3.7 | 750 | 500 | 1750 | -- | 83 | SW-3N |
downside | 30 | 2.7 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 1750 | 83 |
upside(connect blast cap) | 30 | 2.7 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 2000 | 86.5 |
|
constant temperature precision air conditioners |
|
model number | total/sensible cooling capacity | electric heating | air flow | air blowing way | external static pressure | cooling power input | fan motor power | noise level | water cooled condenser | humidifier | dimensions | weight | outside unit |
water cooled | air cooled | water cooled | air cooled | piping connection | water flow | water resistance | capacity | power | width | depth | height | water cooled | air cooled |
kw | kw | kw (grade) | m3/h | Pa | kw | kw | kw | dB(A) | m3/h | MPa | kg/h | kw | mm | mm | mm | kg | kg |
JH15/JHF14 | 15.3/13.6 | 13.8/12.2 | 6(2) | 4200 | upside | 60 | 4.5 | 5.0 | 1.1 | ≤57 | 1-1/4" | 3.6 | 0.065 | 4 | 3.7 | 1245 | 800 | 1950 | 420 | 400 | SW-5N |
downside | 60 | 4.5 | 5.0 | 1.1 | ≤57 | 4 | 3.7 | 1245 | 800 | 1950 | 420 | 400 |
upside(connect blast cap) | 60 | 4.5 | 5.0 | 1.1 | ≤56 | 4 | 3.7 | 1245 | 800 | 2200 | 430 | 410 |
|
JH24/JHF22 | 24.4/22.3 | 21.7/19.5 | 9(3) | 6800 | upside | 60 | 7.8 | 8.0 | 1.5 | ≤60 | 1-1/2" | 5.4 | 0.085 | 4 | 3.7 | 1920 | 840 | 1800 | 470 | 465 | SW-4N*2 |
downside | 60 | 7.8 | 8.0 | 1.5 | ≤60 | 4 | 3.7 | 1920 | 840 | 1800 | 470 | 465 |
JH32/JHF29 | 31.5/28.3 | 28.8/25.5 | 9(3) | 8000 | upside | 60 | 9.5 | 8.0 | 2.2 | ≤62 | 1-1/2" | 7.0 | 0.065 | 4 | 3.7 | 1920 | 840 | 1800 | 491 | 485 | SW-5N*2 |
downside | 60 | 10.3 | 9.8 | 3 | ≤62 | 4 | 3.7 | 1920 | 840 | 1800 | 491 | 485 |
JH39/JHF34 | 39.3/35.1 | 33.6/29.9 | 15(3) | 10000 | upside | 60 | 11.4 | 10.6 | 3 | ≤63 | 1-1/2" | 9.0 | 0.073 | 4 | 3.7 | 1920 | 840 | 1800 | 512 | 506 | SW-5N*3 |
downside | 60 | 12.4 | 12.4 | 4 | ≤63 | 4 | 3.7 | 1920 | 840 | 1800 | 512 | 506 |
JH48/JHF43 | 47.5/43.3 | 42.5/38.8 | 18(3) | 12000 | downside | 70 | 14.6 | 15.9 | 3 | ≤68 | 2" | 11.0 | 0.085 | 8 | 6.1 | 2320 | 940 | 2100 | 730 | 720 | SW-5N*3 |
JH64/JHF58 | 64.4/58.3 | 57.6/52.1 | 18(3) | 15000 | downside | 70 | 20.4 | 21.9 | 4 | ≤69 | 2" | 14.5 | 0.09 | 8 | 6.1 | 2320 | 940 | 2100 | 752 | 731 | SW-10N*2 |
JH73/JHF67 | 73/66.4 | 67.2/61 | 30(3) | 17000 | downside | 70 | 22.1 | 25.1 | 4 | ≤71 | 2" | 17.7 | 0.073 | 13 | 9.8 | 2320 | 940 | 2100 | 1271 | 1040 | SW-13N*2 |
JH92/JHF85 | 92/83.2 | 85/76.5 | 36(3) | 24000 | downside | 70 | 29.2 | 31.8 | 5.5 | ≤71 | 2-1/2" | 22.0 | 0.078 | 13 | 9.8 | 2500 | 940 | 2100 | 1271 | 1040 | SW-10N*3 |
JH108/JHF102 | 108/98.5 | 102/91.8 | 36(4) | 28000 | downside | 80 | 33.5 | 37.9 | 7.5 | ≤72 | 2-1/2" | 27.5 | 0.082 | 25 | 18.75 | 2550 | 940 | 2100 | 1271 | 1040 | SW-13N*3 |
JH146/JHF135 | 146/131 | 135/122.3 | 56(5) | 34000 | downside | 80 | 44.3 | 50.3 | 11 | ≤72 | 3" | 35.5 | 0.092 | 25 | 18.75 | 4500 | 940 | 2100 | 1271 | 1040 | SW-13N*4 |
| | | | | | | | | | | | | | | | | | | | | |
1. The temperature control range and accuracy is (18~32)±0.5ºC; | | | | | | | | | | | | |
2. The humidity control range and accuracy is (40~80%)±3%; | | | | | | | | | | | | |
3. The voltage is 3N~380V,50HZ. | | | | | | | | | | | | |
4. The JH series are for water cooled precision units, and the JHF series are for air cooled precision units. | | | | | | | | | | | | |
5. Owing to technological advances, the above specifications are subject to change without notice. | | | | | | | | | | | | |
Outside Units |
model number | SW-3N | SW-5N | SW-8N | SW-10N | SW-13N |
motor power | KW | 0.2 | 0.28 | 0.55 | 0.75 | 1.1 |
noise level | dB(A) | 62 | 64 | 70 | 71 | 73 |
voltage | 3N~50HZ 380V |
connection pipes | gas pipe | Φ15.9 | Φ19.1 | Φ19.1+Φ12.7 | Φ19.1 | Φ19.1 |
number | 1 | 1 | 1 | 2 | 2 |
liquid pipe | Φ9.5 | Φ12.7*1 | Φ12.7+Φ9.5 | Φ12.7 | Φ12.7 |
number | 1 | 1 | 1 | 2 | 2 |
connection way | flare opening connected by screw thread | | |
dimensions | width(mm) | 650 | 800 | 1000 | 1050 | 1200 |
depth(mm) | 650 | 800 | 1000 | 1050 | 1200 |
height(mm) | 800 | 950 | 1200 | 1300 | 1300 |
weight | kg | 76 | 105 | 176 | 203 | 280 |
3) Display:4)Packing
5)Our company file