10kv, 11kv, 12kv Output 100va Accuracy 0.5 Class Indoor Voltage Measuring Instrument Test Report Qualified

China 10kv, 11kv, 12kv Output 100va Accuracy 0.5 Class Indoor Voltage Measuring Instrument Test Report Qualified, Find details about China Voltage Transformer, Current Transformer from 10kv, 11kv, 12kv Output 100va Accuracy 0.5 Class Indoor Voltage Measuring Instrument Test Report Qualified

Model NO.
JDZ10-10B
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use,Epoxy Resin,Sealed Structure
Trademark
DHECN
Transport Package
1PCS/CTN
Specification
GB 1208, ISO9001, CCC, IEC
Origin
China
HS Code
8504311000
Model NO.
JDZ10-10B
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use,Epoxy Resin,Sealed Structure
Trademark
DHECN
Transport Package
1PCS/CTN
Specification
GB 1208, ISO9001, CCC, IEC
Origin
China
HS Code
8504311000
JDZ10-3,6,10 Type Voltage Transformer
Applications
JDZ10-3,6,10 Voltage Transformer is suitable for power measurement, current monitoring and relay protection in power system with Rated frequency 50Hz or 60Hz and Rated voltage 3~10kV. 
Applicable Standard: IEC60044-2
Type Designation
  
Operation Conditions
Installation area: Indoor.
Ambient temperature: Max. temperature 40ºC;Min. temperature -5ºC;Daily average temperature can't exceed 30ºC.
Air conditions: No heavy pollution in air.
Technical Parameter
 
ModelRated voltage radio 
(kV)
Combined accuracy or Combined accuracy classesRated output
(VA)
ltimate output
(VA)
Rated insulation level
(kV)
JDZ10-33/0.10.2152003.6/25/40
0.530
JDZ10-66/0.10.2152007.2/32//60
0.530
JDZ10-1010/0.10.21520012/42/75
0.530
 
Structure and Feature
The series PT is post type. Its hemetically sealed by epoxy resin, with design advantages of anti-pollution, anti-damp, easy to be installed, which is also suitable for tropic area and free from special maintenance except periodically surface clean. Secondary outlet teminal is equipped with connection teminal box. Upside and profile of the box have a hole respectively. The two holes together with outlet terminal are for leading out.There have earth bolt at the bottom of the PT. Six holes at the bottom of the PT are suitable for mounting.
 
Information Required for Order Placing
Model.
Rated voltage radio kV.
Combined accuracy classes and Rated output VA.
Altitude m.


10kv, 11kv, 12kv Output 100va Accuracy 0.5 Class Indoor Voltage Measuring Instrument Test Report Qualified

10kv, 11kv, 12kv Output 100va Accuracy 0.5 Class Indoor Voltage Measuring Instrument Test Report Qualified