Fu-100 Clamp CT Split Core Current Transformer Manufacturers China

Fu-100 Clamp CT Split Core Current Transformer Manufacturers China, Find details about China Clamp CT Manufacturers, Clamp CT China from Fu-100 Clamp CT Split Core Current Transformer Manufacturers China

Model NO.
FU-100
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Ratio
1000: 5 or 2000:5 , Customized
Key Words
Clamp CT Manufacturers
Model
Clamp CT Transformer
Overload Withstand
1.2 Times Rated Current Continuously
Accuracy
0.2%, 0.5 %, 1%
System Voltage
720V(0.72kv)
Output Signal
1A or 5A 333mv AC or 100mv-2V Optional
Burden
2.5va
Frequency Range
40 Hz-500 Hz
Max. Jaw Opening
100 mm
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
Max. jaw opening 100mm
Origin
Beijing, China
Model NO.
FU-100
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Ratio
1000: 5 or 2000:5 , Customized
Key Words
Clamp CT Manufacturers
Model
Clamp CT Transformer
Overload Withstand
1.2 Times Rated Current Continuously
Accuracy
0.2%, 0.5 %, 1%
System Voltage
720V(0.72kv)
Output Signal
1A or 5A 333mv AC or 100mv-2V Optional
Burden
2.5va
Frequency Range
40 Hz-500 Hz
Max. Jaw Opening
100 mm
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
Max. jaw opening 100mm
Origin
Beijing, China
Product Name
FU-100 Clamp ct Split Core Current Transformer manufacturers china

The GFUVE FU-100 clamp ct transformer are compact and low cost current transformers with high accuracy.
The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple
installation mechanisms provide stable and durable current measurement.
Applications
1. Energy sub - meter
2. Power meters
3. Power quality monitoring
4. HVAC & Pumps, etc
5. Distributed measurement system
Features
1. Most cost-effective
2. Faster installation
3. Safe and easy installations
4. High accuracy 0.5
5. Holding wire diameter: φ100mm
6. Ratio's ranging from 400/1A to 3000/5A
7. CE, UL
Parameters
Technical parameters 
StandardsIEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio1000: 5 or 2000:5 , customized
Nominal input current(Primary current)400A/500A/600A/800A/1000A/1200A/1500A/2000A/3000A
Overload withstand1.2 times rated current continuously
Accuracy0.2%, 0.5 %, 1%
System Voltage720V(0.72kV)
Output signal1A or 5A
333mV AC or 100mV-2V optional
Burden2.5VA
Frequency range40 Hz-500 Hz
Dielectric strength3KV 50Hz/60Hz at 1 minute
OutputStandard 2.5 meter cable
Max. jaw opening100mm
Mechanical parameters
Dimensions (W×D×H) (mm)170mm×184.5mm×41mm
Weight(Kg)1
Operating conditions
Operating temperature-25°C to +55°C
Relative Humidity0-85% non-condensing
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and 
radioactive gas in the air. Permission of long-term 