China Cold Applied Breakout for Cable Protection up to 52kv, Find details about China Cold Shrink, Tube from Cold Applied Breakout for Cable Protection up to 52kv
Type | Dimension D1 (mm) | Dimension D2 (mm) | Dimension d1 (mm) | Dimension d2 (mm) |
UECSB 1# | 75 ± 1 | 38 ± 1 | 31 ± 1 | 14 ± 0.5 |
UECSB 2# | 92 ± 1 | 43 ± 1 | 36 ± 1 | 16 ± 0.5 |
UECSB 3# | 105 ± 1 | 53 ± 1 | 41 ± 1 | 19 ± 0.5 |
UECSB 4# | 120 ± 1 | 62 ± 1 | 48 ± 1 | 23 ± 0.5 |
UECSB 5# | 160 ± 1 | 68 ± 1 | 67 ± 1 | 27 ± 0.5 |
No | Test Item | Test method | Test value |
1 | Hardness (Shore A) | GB/T 531.1 | 39 |
2 | Tensile strength (Mpa) | GB/T 528 | 10.1 |
3 | Tear resistance, Die B (N/mm) | GB/T 529 | 38 |
4 | Elongation at break (%) | GB/T 528 | 820 |
5 | Volume resistance (Ω.cm) | GB/T 1692 | 3.01×1015 |
6 | Fungus resistance 28 days exposure | ASTM G-21 | No growth |
7 | Moisture aborption 7 days 90°C (1940F) H2O | - | wt gain 1.8% |