HP-HEMA6000 Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory.
Model | HP-HEMA6000 |
Voltage | 98V-264V |
Advantages:
1,Fully automated to increase productivity
2,3-part differential cell counter with 22 parameter and laser light source
3,Direct tube sampling from original collection vials for operator safety
4,Bar code capability to reduce manual input
5,Proven technology to provide accurate results
6,More than 60 samples per hour
7,Minimum maintenance required
The machine is mainly used for the quantitative measurement of the blood in the 19 parameters and 3 histograms:
1 The total amount of WBC WBC
2 The amount of Lymphocyte Ly#
3 The amount of Monocyte MO#
4 The amount of Granulocyte GR#
5 Lymphocyte percentage Ly%
6 The percentage of mononuclear cells MO%
7 Granulocyte percentage GR%
8 The total amount of red blood cells RBC
9 Hemoglobin HGB
10 Hematocrit HCT
11 Mean volume of red blood cells MCV
12 Mean corpuscular hemoglobin MCH
13 Mean corpuscular hemoglobin concentration MCHC
14 Red blood cell volume distribution width Coefficient of variation RDW-cv
15 The standard deviation of red blood cell volume distribution width RDW-sd
16 The total amount of platelet PLT
17 Mean platelet volume MPV
18 Plateletcrit PCT
19 Platelet distribution width PDW
20 White blood cell distribution histogram WBC Histogram
21 Red blood cell distribution histogram RBC Histogram
22 Platelet distribution histogram PLT Histogram
Main Parameters:
- 1.Use impedance method for RBC and platelet count
- 2. Cyanide free for Haemoglobin test
- 3. Flow cytometry +laser light scatter + chemical dye method for WBC differential analysis
- 4.Fully automated with an autoloader and sampler
- 5. Should use both closed tube sampling and open tube sampling
- 6. 2 counting mode, whole blood and pre-diluted mode
- 7. With histograms and scattergrams for differential results
-8. Throughput of at least 60 samples per hour
-9. Automatic flagging system for abnormal results and automatic sample re-run
-10. Automatic validation of results on a dedicated PC with at least a 10.4" colour monitor
- 11.Data storage capacity of at least 20,000 results
- 12.Optional integrated slide maker and on-board cytology atlas
- 13.Optional colour printer an on-board diagnostics
- 14.Flexible communication/connection (USB)
- 15.Operating temperature of 10 oc -35oc and humidity of up to 85%
-16. Floppy disc drive and DVD writer
-17. Power 98V-264V
-18. The equipment should be accompanied with all manufacturers' recommended spare parts
Supply one year quanlity guarrantee for main body and free training 2 persons for first time.Reagents can be supplied by original produced by ourselves.Various technical support and maintanance suggest by our professional application engineers and sales engineers.