Commercial Use Air Cooled Chiller

China Commercial Use Air Cooled Chiller, Find details about China Chiller, Heat Pump Chiller from Commercial Use Air Cooled Chiller

Model NO.
ESGA-40STN
Mounting
Floor Standing
Lifetime
>20 years
Certification
CE
Condition
New
Water Chiller Compressor
Taiwan Hanberll
Water Chiller Controller
Punp or Siemens
Water Chiller Expansion Valve
Emerson
Trademark
Eurostars
Specification
CE
Origin
Guangdong, Prc
HS Code
8418692090
Model NO.
ESGA-40STN
Mounting
Floor Standing
Lifetime
>20 years
Certification
CE
Condition
New
Water Chiller Compressor
Taiwan Hanberll
Water Chiller Controller
Punp or Siemens
Water Chiller Expansion Valve
Emerson
Trademark
Eurostars
Specification
CE
Origin
Guangdong, Prc
HS Code
8418692090
1.Eurostars air cooled screw type water chiller 
a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
g)CE certificated
 
2.Eurostars Water Chiller Features
1).The Chiller cooling capacity ranged from 100Kw to 800 Kw.
2). Adopt good quality famous brand HANBELL compressor,high efficiency, low noise, less 
  wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life. 
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area,such as in commercial AC, Massage center, Hospital, Hotel, School, etc 
9). Strong unit base frame ensured the equipment stable operation 
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R410A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled water range: 5°C to 20°C
 

3.Eurostars water chiller protection devices
1)Phase reversion protection, 
2)Phase lack protection, 
3)Overload current protection,
4)Discharge air temp. protection, 
5)Low & High pressure protection, 
6)Low temp. protection, 
7)Water flow protection.
 
 
4.Eurostars water cooled chiller technical parameter

Refrigerant-R407C
Air Cooled Chiller Unit (Screw Type Compressor-one compressor)
 Model     ESGA-30STN40STN55STN65STN75STN85STN90STN
Rated Cooling CapacityKW111161215254294321346
USRT31.57 45.79 61.15 72.24 83.62 91.30 98.41 
X 1000Kcal/h95.46 138.46 184.90 218.44 252.84 276.06 297.56 
 Comp. lnput Power×Qty (KW)34.6×148.2×163.8×170.5×182.4×190.2×198.9×1
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)19.09 27.69 36.98 43.69 50.57 55.21 59.51 
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8

Air Cooled Chiller Unit (Screw Type Compressor-two compressor)
 Model     ESGA-100DTN110DTN130DTN140DTN150DTN165DTN180DTN
Rated Cooling CapacityKW392429509537588642693
USRT111.49 122.01 144.77 152.73 167.24 182.59 197.10 
X 1000Kcal/h337.12 368.94 437.74 461.82 505.68 552.12 595.98 
 Comp. lnput Power×Qty (KW)58.2×263.8×270.5×274.1×282.4×290.2×298.9×2
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)67.42 73.79 87.55 92.36 101.14 110.42 119.20 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16

Refrigerant-R22
 Model     ESGA-30STS45STS60STS70STS80STS85STS95STS
Rated Cooling CapacityKW119170228269310337369
USRT33.85 48.35 64.85 76.51 88.17 95.85 104.95 
X 1000Kcal/h102.34 146.20 196.08 231.34 266.60 289.82 317.34 
 Comp. lnput Power×Qty (KW)34.7×147.7×163.2×171.2×182.4×189.9×199.9×1
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)20.47 29.24 39.22 46.27 53.32 57.96 63.47 
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8


 Model     ESGA-110DTS120DTS140DTS150DTS160DTS175DTS190DTS
Rated Cooling CapacityKW415456537568620672740
USRT118.03 129.69 152.73 161.55 176.34 191.13 210.47 
X 1000Kcal/h356.90 392.16 461.82 488.48 533.20 577.92 636.40 
 Comp. lnput Power×Qty (KW)58.1×263.2×271.2×274.9×282.4×289.9×299.9×2
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
Condenser Ripple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)71.38 78.43 92.36 97.70 106.64 115.58 127.28 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16



4.Eurostars water chiller Quotation Remarks
-1.Packing: Standard export package
-2.Delivery Day: 25~35 working days after deposit is confirmed
-3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
-4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
-5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, 
we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
-6.Validity: 20 days
-7.Payment currency: USD
 
5.Eurostars water chiller series
-Commercial Water Cooled Chiller
-Scroll type water cooled water chiller
-Screw type water cooled water chiller
-Flooded type water cooled water chiller
 
-Commercial Air Cooled Chiller
-Scroll type air cooled water chiller
-Screw type air cooled water chiller
 
-Industrial Chiller
-Air cooled industrial chiller(with heat recovery)
-Water cooled industrial chiller(with heat recovery)
-Glycol chiller (with heat recovery)