Acrel Agf -M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays

China Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays, Find details about China Solar PV Energy Meter, Multi Channel DC Energy Meter from Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays

Model NO.
AGF-M12T
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
PV Confluence Acquisition Device
Brand
OEM ODM
Rated Input Current
DC0-20A
Accuracy
Class 0.5
Relay Output
2 No 5A/AC250V(5A/DC 30V)
Communication
RS485 Interface, Modbus-RTU
Trademark
ACREL
Transport Package
Fob Shanghai
Origin
China
Model NO.
AGF-M12T
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
PV Confluence Acquisition Device
Brand
OEM ODM
Rated Input Current
DC0-20A
Accuracy
Class 0.5
Relay Output
2 No 5A/AC250V(5A/DC 30V)
Communication
RS485 Interface, Modbus-RTU
Trademark
ACREL
Transport Package
Fob Shanghai
Origin
China
Product Description

AGF-M12T 12 string solar box monitor device with built-in hall effect CT for array pv combiner box

General
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.

Function
1.Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively
2.With 3-channel switching state monitoring to collect output idle contact information of DC breaker ,lightning protector. protector etc
3.Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format English LCD display,convenient to set parameters and check the data
 

Technical Parameters
 
ModelAGF-M4TAGF-M8TAGF-M12TAGF-M16TAGF-M20TAGF-M24T
PV array string input4812162024
Rated input currentDC0-20A,3.5KV hall current sensor isolation
Accuracy0.5
Relay output2 NO 5A/AC250V(5A/DC 30V)
Digital input3 external state input(optocoupler or dry contact
Analog inputPT100,DC4-20ma or DC0-10V
CommunicationRS485 Modbus-RTU
Baud rate4800/9600/19200/38400bps
Auxiliary power supplyDC1000V(1KV no damage)OR DC1500V(±10%)
Optional functionMJ(Analog input plus relay output(PT100,DC4-20ma or dc0-10v) plus 2 NO 5A/AC250V(5A/DC30V)
B(power supply filter module)
L(LCD)
P2(Auxiliary power supply:DC1000V)
P3(Auxiliary power supply:DC1500V)


Characteristics
 
1Primary current is connected in through perforation. Easy installation, high safety.
2With Hall sensor, the max isolation measuring current 20A
3Voltage measurement range for Bus bar is up to DC1kV
4LED display, fit for checking and testing operation in wide-temperature or outside environment.
5With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box
6With RS485 Modbus RTU
7More options of power supply
8Compatible with din rail installation and baseboard fixation installation, small dimension saving more
box space.
9DC Bus bar voltage input circuit with built-in DC 1kV fuse


Dimension(Unit:mm)

Power supply module and power supply filtering module size(Figure 1)

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays


The extension module mounting dimensions (Figure 2)

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays


 Confluence acquisition module installation dimension

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays
Configuration of 8-channel or 4-channel confluence acquisition module will be decided by actual needs: when 4 channels or less are needed, 4-channel confluence acquisition module will be installed, when needed channel number is 5 to 8, 8-channel confluence acquisition module will be installed. When needed channel number is more than 8, then the number will be divided by 8. If there is a remainder in the result and the remainder is less than 4, then 4-channel confluence acquisition module will be installed. If the remainder is more than 4, 8-channel confluence acquisition module will be installed.


8-channel confluence acquisition module installation dimension(Figure 3)

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays

4-channel confluence acquisition module installation dimension(Figure 4)

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays


 LCD display module installation dimension (Figure 5)

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays

Connections of modules
Data cable connection way
The connection between each module is through the external data line. Please confirm the sequence of the two external data line ports before connecting each module. Each confluence acquisition module has two outside connection ports(Figure 4): Port I and Port II, in which Port I is used to connect upstream module and Port II is used to connect follow-up modules. Please pay attention to it that the propulsion part of the data line connector must be fixed with the groove on the port.
The connection sequence order of PV confluence acquisition modules must follow: confluence acquisition module 1's port third grade-->confluence acquisition module 2's port , first grade confluence acquisition module 2's port third grade-->confluence acquisition module 3's port .When connecting the confluence acquisition modules ,multiple confluence modules should be in sequence order, it is not allowed to insert any other function module between two sequenced confluence modules. Wrong connection will lead to abnormal operation of the device.
LCD display module can be connected with Port II of confluence acquisition module, The LCD display module is not necessary to be connected in at ordinary time except when testing and checking.
The address allocation of PV confluence acquisition module is automatically distributed by the power module(main module), The first confluence acquisition module connected to the power module will be distributed automatically with 1st to 8th channels, and the next confluence acquisition module connected to port II will be distributed automatically with 9th to 16th channels, the final confluence acquisition module is distributed automatically with 17th to 24th channel.


Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays


Installation

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays


Definition of input port

After the address of confluence acquisition module is distributed by the main module,the input channel address of first module is from 1st to 8th channel,the input channel address of second confluence acquisition module is from 9th to 16th channel,the input channel address of final confluence acquisition module is from 17th to 24th channel. The input channel definition of 1st to 8th channel of a single module is shown as Figure 3.

Wiring
Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays



Note: Power supply circuit and voltage measuring circuit must be installed with fuse with 3A rated current and rated voltage that is the highest working voltage in these circuits to ensure safety.

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays

Certificate

Acrel Agf-M12t PV Convergence Box Multi Channel DC Energy Meter Monitoring The Running State of Solar Panels in Solar Cell Arrays