China Tecway 4.0mm Sbs/APP Modified Bituminous Puncture-Resistance to Root Waterproof Membrane for Building Green Roof Waterproofing Materials, Find details about China Waterproof Material, Waterproof Membrane from Tecway 4.0mm Sbs/APP Modified Bituminous Puncture-Resistance to Root Waterproof Membrane for Building Green Roof Waterproofing Materials
Puncture-Resistance to Root Waterproof Membrane for Green Roof
Overview:
Puncture-Resistance to Root Waterproof Membrane for Green Roof specially design for planting roof, roof garden application. This product has good resistance to root penetration and waterproof function, simple to construct, longer service life of more than 50 years, is the best choice of waterproof solution for planting roof and roof garden.
Performance Index:
Basic performance and requirement
No. | Standard Name | Requirement |
1. | Elastomer Modified Asphalt Waterproof Membrane | All requirement for Type II of GB18242-2008 |
2. | Plastomer Modified Asphalt Waterproof Membrane | All requirement for Type II of GB18243-2008 |
3. | Polyvinyl Chloride (PVC) Waterproof Membrane | All requirement of GB12952-2011 (Exposure Membrane) |
4. | Thermoplastic Polyolefin (TPO) Waterproof Membrane | All requirement for of GB27789-2011 (Exposure Membrane) |
5. | Polymer Waterproof Membrane | All related requirement of GB18242-2008 |
6. | Polyethylene Modified Asphalt Waterproof Membrane | All requirement for Type R of GB18967-2009 |
Application and related requirement:
No. | Items | Technical Parameter | |||
1. | Resistance to Mold & Corrosion | Mold-Proof Level | Grade 0 or Grade 1 | ||
2. |
| Non-Treatment | Asphalt Waterproof Membrane | SBS | ≥ 1.5 |
APP | ≥ 1.0 | ||||
Asphalt Waterproof Membrane | Welding | ≥3.0 or Membrane Damage | |||
Bonding | ≥ 1.5 | ||||
Rubber Waterproof Membrane | ≥ 1.5 | ||||
Retention Rate after Thermal Aging Treatment | ≥80 or Membrane Damage |
Notes:
1. The structural layer of planting roof should adopt cast-in-place reinforced concrete. The structural bearing capacity design of new planting roof must include planting load. When the existing building roof is transformed into planting roof, the load must be within the allowable range of roof structure bearing capacity.
2. The design of planting roof construction should follow the principle of "Paying Equal Attention to Prevention, Drainage & Planting; Safety, Environmental Protection, Energy Conservation, Economy, and Suit to Local Conditions", and consider the practicality of construction environment and technology.
3. When the roof slope is greater than 20%, the thermal insulation layer, waterproof layer, drainage (storage) layer and planting soil layer should be taken anti-skid measures; when the roof slope is greater than 50%, it is not easy to make planting roof.
4. Inverted roof should not be covered with soil.
5. Planting design shall combine covering soil planting with container planting, and also combining with ecology and landscape.
6. The green area of simple planting roof should account for more than 80% of the total roof area; the greening area of garden planting roof should account for more than 60% of the total roof area.
7. It is not suitable to plant large arbors trees on the roof of areas with wind above level 6 all year round.