200mm Woltman Type Remote Control Smart Residential Water Flow Meter

China 200mm Woltman Type Remote Control Smart Residential Water Flow Meter, Find details about China 200mm Water Meter, Residential Water Flow Meter from 200mm Woltman Type Remote Control Smart Residential Water Flow Meter

Nominal Diameter
DN40~DN600
Application
Civil, Industrial
Principle
High Flows of Cold Potable Water
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Body
Brass
Standard
ISO 4064 Class B, R50, R63 and R80 Standard
Port Connect
Flange
Trademark
TIANYI SUNS
Transport Package
Carton or as Customer′s Request.
Specification
40mm~600mm
Origin
China
Nominal Diameter
DN40~DN600
Application
Civil, Industrial
Principle
High Flows of Cold Potable Water
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Body
Brass
Standard
ISO 4064 Class B, R50, R63 and R80 Standard
Port Connect
Flange
Trademark
TIANYI SUNS
Transport Package
Carton or as Customer′s Request.
Specification
40mm~600mm
Origin
China
200mm woltman type remote control smart residential water flow meter
 
Product Description
BodyBrass
Size40mm~600mm
StandardISO 4064 Class B, R50, R63 and R80 standard
Water Temperature≤50ºC for cold water meter
≤90ºC for hot water meter
Water Pressure≤1MPa or 1.6MPa or 4.0 MPa optional (10bar or 16bar r 40 bar optional)
Port Connectflange
ApplicationFor the measurement of high flows of cold potable water passing through the pipelines in sizes of 40mm to 600mm.
Packagingcarton or as customer's request.
MOQ10PCS
Brand NameTIANYI SUNS

 

Detailed Photos

 

200mm Woltman Type Remote Control Smart Residential Water Flow Meter200mm Woltman Type Remote Control Smart Residential Water Flow Meter

 
Application

For the measurement of high flows of cold potable water passing through the pipelines in sizes of 40mm to 600mm.

 

Feature

* Adopting M-BUS or RS485 communication mode.

* Electronic parts are separately sealed, and the water proof can be IP68.

* Highest accuracy, lowest error, low starting flow rate.

* Multi jet dry type water meter.

* Magnetic drive, lower transmission resistance, frog-resistant.

* Magnetic shield, for external magnetic field protection

* Low power consumption.

* Being stable and reliable by the "position identification" characteristics of photoelectric and microelectronic technology.

* Automatic reading and management.

* Each meter has an unique location number, easy wire construction.


Standard Compliance

Technical data conforms to ISO 4064 Class B, Class C, R80, R100, R125 or R160 standard for horizontal installation.




Optional Features

* Meter body: Brass and iron for selecting.

* Communication interface mode: RS485 interface or MBUS interface (optional)

* Communication transmission rate: 1200bps, 2400bps, 4800bps or 9600bps (optional)

*Communication specification: CJ/T188-2004 agreement, DL/T645-2007 or MODBUS Agreement (optional), or a special agreement to be made to order.



Working Conditions

*Power Supply: DC 9-24V (RS485 interface) and DC24-42V(MBUS interface);

* Humidity: 0~95% RH

*The distance between data collector and meter: ≤300m;

* Power consumption: ≤1uA (Static Working Current); ≤12uA (instant current during remote reading)

* Water temperature: ≤50ºC for cold water meter

* Water temperature: ≤90ºC for hot water meter

* Water pressure: ≤1MPa or 1.6MPa optional (10bar or 16bar optional)


Installation requirements
*The meter should be installed in vertical position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.

*Pipeline must be flushed before installation.

*The meter should be constantly full of water during operation.




Maximum Permissible Error
In the lower zone from Qmin(Q1) inclusive up to but excluding Qt (Q2) is ±5%.

In the upper zone from Qt(Q2) inclusive up to and including Qmax(Q4) is ±2%(cold water meter).

In the upper zone from Qt(Q2) inclusive up to and including Qmax (Q4) is ±3% (hot water meter). 

Accessories

Each water meter has one set couplings optional: 2pcs tube, 2pcs nut and 2pcs gasket.



MAIN TECHNICAL DATA According to ISO4064 :2003 (Old Standard)
 
Meter SizeMeasuringMax FlowNominal FlowTransitional FlowMin FlowMin ReadingMax Reading 
 
mmclassm³/h  
40B20100.80.20.0002999999 
50B301530.450.0002999999 
65B502550.750.0002999999 
80B804081.20.002999999 
100B12060121.80.002999999 
125B2001002030.002999999 
150B300150304.50.002999999 
200B500250507.50.002999999 
250B80040080120.002999999 
300B1200600120180.029999999 
350B1600800160240.02999999999 
400B20001000200300.02999999999 
500B30001500300450.02999999999 
600B60003000600900.02999999999 


MAIN TECHNICAL DATA According to ISO4064:2005 (New Standard)
 
Meter SizeMeasuringQ4Q3Q2Q1Min ReadingMax Reading
mmRm³/h    
406320160.410.250.0002999999
506331.25250.630.400.0002999999
658050400.800.500.0002999999
808078.7631.260.790.002999999
100801251002.001.250.002999999
125802001603.202.000.002999999
15080312.52505.003.130.002999999
2006350040010.166.350.002999999
2505078763020.1612.600.002999999
300501250100032200.029999999
350502000160051.2320.02999999999
400503125160051.2320.02999999999
500505000250080500.02999999999
6005078704000128800.02999999999



Dimensions and Weight

200mm Woltman Type Remote Control Smart Residential Water Flow Meter
Meter sizeLength LWidth BHeight HConnecting thread
mmmmDBolt circle Dia D1Connecting bolt
402002564001651254xM16
502002564001651254xM16
652002564001851454xM16
802252764002001608xM16
1002502864002201808xM16
1252503014002502108xM16
1503003465002852408xM20
2003503735003402958xM20
25045049373039535012xM20
30050051673044540012xM20
35050056073052047012xM21
40060063183056551516xM24
50080078593071565020xM30
6001000865103084077020xM33


 
Related Products