Mechanical Water Meter Gauge Cold Water Meter ISO 4064

China Mechanical Water Meter Gauge Cold Water Meter ISO 4064, Find details about China Gauge, Mechanical Water Meter from Mechanical Water Meter Gauge Cold Water Meter ISO 4064

Model NO.
LXSG-15E-50E
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Trademark
OEM
Transport Package
Export Carton
Specification
Cast iron body, brass head ring, brass connectors
Origin
Ningbo, China
HS Code
9028201000
Model NO.
LXSG-15E-50E
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Trademark
OEM
Transport Package
Export Carton
Specification
Cast iron body, brass head ring, brass connectors
Origin
Ningbo, China
HS Code
9028201000

Mechanical Water Meter Gauge Cold Water Meter ISO 4064
 

Multi jet, Dry-dial

Material body: Cast gray iron / Ductile cast iron

Size: DN15 to 50mm, (½" - 2"), Available for cold water (40°C), hot(90°C)

Accuracy: ISO 4064 Class B Standard

Universal use. Easy for interchange & maintenance
 

MAIN TECHNICAL DATA

Meter size
Dia
DN
(mm)
Classqs
Overload
Flow
qs
Nominal
Flow
qs
Transitional
Flow
Qmin
Min
Flow
Min
Reading
Lectura
Max
Reading
Lectura
m3/h1/hm3
15A31.5150600.000199999
B12030
20A52.52501000.000199999
B20050
25A73.53501400.000199999
B28070
32A126.06002400.000199999
B480120
40A201010004000.00199999
B800200
50A3015450012000.00199999
B3000450


INDICATING ERROR

At low zone is ±5% from minimum flow rate  (qmin)  to transitional flow rate (qt) exclusive boundary

At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
 

DIMENSIONS AND WEIGHT

Meter size
Dia
DN
(mm)
LengthWidthHeightConnecting Thread
D
Weight
Kg
mm
1516599104G 3/4B1.5
2019099106G 1B1.7
25225104120G1 1/4B2.4
32230104120G1 1/2B2.7
40245125155G 2B4.5
50300125155G2 1/2 B7.2
280165175FLANGE CONNECTING CONFORM TO
GB4216.4 D=165 D1=125
14


WORKING CONDITION

Water temperature:≤40ºC for cold water meter

Water temperature:≤90ºC for hot water meter

Working pressure:≤1.6Mpa