35mm DIN Rail Passive Voltage Current Resistance to 4-20mA Loop Powered Converter

China 35mm DIN Rail Passive Voltage Current Resistance to 4-20mA Loop Powered Converter, Find details about China 4-20mA Converter, 0-5V to 4-20mA from 35mm DIN Rail Passive Voltage Current Resistance to 4-20mA Loop Powered Converter

Model NO.
DIN1x1 ISO U/A/R-O Series
Isolation
3000vrms
Vin  
30VDC
Junction Temperature  
- 40 ~ +85 ºC
Storage Temperature 
  +150ºC
Trademark
SUNYUANSZ
Transport Package
Carton Box
Specification
SIP PCB-mounted
Origin
Shenzhen
HS Code
9026900000
Model NO.
DIN1x1 ISO U/A/R-O Series
Isolation
3000vrms
Vin  
30VDC
Junction Temperature  
- 40 ~ +85 ºC
Storage Temperature 
  +150ºC
Trademark
SUNYUANSZ
Transport Package
Carton Box
Specification
SIP PCB-mounted
Origin
Shenzhen
HS Code
9026900000
35mm DIN Rail Passive Voltage Current Resistance to 4-20mA Loop Powered Converter 
ISO U/A/R-O Series

Features
-Unique high efficient loop powered technique, external power supply is not required. 
-Designed for various types of analog signal input, loop powered output. 
-2-wire, 3-wire, 4-wire sensor active signal amplification and isolated transmission. 
-Input terminal accept meters and sensor single or bidirectional voltage or current signal:
 0-75mV/0-5V/0-10V/0-±10mV/0-±5V/0-±10V,ect         
0-1mA/0-10mA/0-±1mA/0-±20mA/4-20mA, etc.
-Input 0-2KΩ / 0-10KΩ, etc resistance or potentiometer signal.
-3kv isolation voltage between analog input loop and current loop output. 
-High accuracy and linearity in full measuring range, non-linearity < 0.1%
-Low cost small size SIP 12Pin, standard PCB-mounted.
-Industrial temperature range: -40 ~ +85 ºC, in compliance with UL94V-0 flame-retardant standards.

Applications
-DC current or voltage signal isolation, amplification and conversion.
-Displacement, weight bridge, potentiometer signal acquisition, isolation and control. 
-mV small signal to standard 4-20mA analog signal conversion.  
- PLC/DCS and meters, sensor signal receiving and transmission. 
- System ground wire current loop interference isolation and inhabitation. 
-Industrial site analog signal long distance transmission and interference isolation.  
- Analog signal transmission between sensor and meters.  
- Industrial system analog signal isolation and conditioning. One input two outputs, one input three outputs, one input four outputs, two input two outputs, and three inputs three outputs transmission.
Continuous Isolation Voltage                                             3000Vrms
Vin                                                                       30VDC
Junction Temperature                                                   - 40 ~ +85 ºC
Storage Temperature                                                    +150ºC
Lead Temperature                                                       +300ºC
Output Short to Common                                                 Continuous

Model selection examples:
E.g.1:  Signal input: 0-10mA; signal output: 4-20mA; PCB-mounted.
          Model No.:  ISO A2-O1

E.g. 2:  Signal input: 0-5KΩ; signal output: 4-12mA; PCB-mounted.                  
          Model No.:  ISO R7-O3

E.g.3:  Signal input: 0-±5V;  signal output: 12-20mA; PCB-mounted.                             
          Model No.:  ISO U5-O5

E.g. 4:  Signal input: 0-±10V;  signal output: 4-20mA;  two-input two-output. 
       Type I standard 35mm DIN Rail-mounted.                
           Model No.: DIN 2 X 2  ISO  U6-O1

E.g. 5:  Signal input: 0-10V;  signal output: 4-8mA; one-input one-output. 
       Small size 35mm DIN Rail-mounted.                          
         Model No.: DIN 3  ISO  U2-O4