1,Overview

Column installed insulation load break switch, type RPS-24 is suitable for the rated voltage 24kV,50/60Hz power grid open circuit,load current in closed Power system , overload current. This load break switch can separate those broken distribution line automatically.
With the latest technology, it has the newest electronic controller.The switch can be used by manual operation, electric operation and operation from a long distance. Electronic controller is installed in a stainless steel cabinet which is suitable for using under all kinds of climatic conditions. In addition, there are some wired and wireless modem installed in the cabinet through which it can realize the remote monitoring and control. Simple installation on column is convenient, fast, and also can reduce the construction cost.
 

2,The standard conditions of use


Operating conditions for SF6 gas load break switch to adapt to:
Ambient temperature
  1. Relative Humidity: 100%
  2.  Ambient air temperature: upper limit +50 ºC, lower limit of -40 ºC.
Elevation does not exceed 1000m;2000m;3000m;5000m
The pressure does not exceed 700pa (equivalent to wind speed of 34m / s).
Earthquake intensity: 8 degrees.
Installation site: No fire, no explosion hazards, no chemical corrosion and recurrent severe vibration.
Pollution class: class III, class IV.
 
  1. SF6 gas-insulated
    1.1 SF6 gas is a kind of nontoxic, nonflammable and electrical insulating gas. It has the excellent characteristic of arc extinction.
    2. Drive pipe with large diversity
    2.1In addition to the standard ceramic drive pipe, we can also provide a variety of solutions, including rubber insulators used in the epoxy resin filling equipment.
    3. Visible open / closed status
    3.1 It is easy to see the main contact position indicator which is color-coded just standing on the ground (Green - off; red - closed). The indicator is directly connected with the main contacts of the drive shaft assembly to ensure accurate display of contact states.
    4 Quick operation
    4.1 operating mechanism with spring energy to ensure a quick closing and opening operation (less than 100
    milliseconds).
    5 Can realize remote control
    5.1 It is equipped with electronic controller, fit for in situ operation as well as FTU interface console operation.
    6. Rugged switch
    6.1 The switch is made of proven durable, corrosion-resistant materials (special used in warships 304L stainless steel plate)which ensures that there is a very long service life (30 years), and can be implement a series of operations.It has the ideal characteristics as a column equipment.
    7 Standard
    7.1 Each switch before leaving the factory has been filled with SF6 gas, sealed, and test according to IEC60265-1, GB40.504 standard.


 

No.
Name
Unit
Data
Product modeRPS-24
1Rated voltagekV24
2Rated frequencyHz50/60



3

Rated insulation level(The filling SF6 gas 0.07Mpa
/ 20 ° C)
(Lightning impulse withstand voltage)relatively
kV
110/125
Fracture145
Power frequency
withstand voltage 1min
relatively
kV
60
Fracture60
4Rated currentA630
5Rated breaking load current (0.07Mpa / 20 ° C)A630
6breaking current under zero gauge pressureA630
7peak withstand currentkA50
8Rated short time making currentkA50
9rated short time withstand currentKA/s20/4
10rated cable charging breaking currentA25
11rated line charging breaking currentA16
12rated closed-loop breaking currentA630
13exciting currentA21
14rated current breaking timesTimes≥400
15rated working pressureMPa0.07
16Per-phase main circuit resistanceμΩ≤150
17relative gas leakage rateyear≤1%

18
SF6 gas moisture contentFactory transfer of valueppm≤150
Switch running valueppm≤300
19operation of echanical stabilitytimes6000
20Casing creepage distancemm840

21

Weight
Type M
kg
125
Type A145
22institutions boxes and controller protection classIP44 IP55
23Type of MountingThe lifting type (suspended)/block (horizontal)
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch
Rps-24kv Type Sf6 Gas Insulated Motorized Mechanism Load Break Switch