China 3 Phase 220V~690V Low Voltage Soft Starter for AC Motors, Find details about China Soft Starter, Soft Start from 3 Phase 220V~690V Low Voltage Soft Starter for AC Motors
Input Voltage | Three-phase 220V/380V/480V/660 AC | ||
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. | (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. | |
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. | (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. | |
Stop Mode | (1) Soft stop. | (2) Free stop. | |
Protective Function | (1)Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14)Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | ||
Temperature | -30 +55 oC | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Model | Current (A) | Standard (kW) | Heavy load (kW) | Model | Current (A) | Standard (kW) | Heavy load (kW) |
ST-GS2-5d5 | 22 | 5.5 | 4 | ST-GS2-075 | 320 | 75 | 55 |
ST-GS2-7d5 | 30 | 7.5 | 5.5 | ST-GS2-090 | 370 | 90 | 75 |
ST-GS2-011 | 45 | 11 | 7.5 | ST-GS2-115 | 400 | 115 | 90 |
ST-GS2-015 | 60 | 15 | 11 | ST-GS2-132 | 500 | 132 | 115 |
ST-GS2-018 | 75 | 18.5 | 15 | ST-GS2-160 | 560 | 160 | 132 |
ST-GS2-022 | 90 | 22 | 18.5 | ST-GS2-185 | 630 | 185 | 160 |
ST-GS2-030 | 110 | 30 | 22 | ST-GS2-200 | 800 | 200 | 185 |
ST-GS2-037 | 150 | 37 | 30 | ST-GS2-220 | 900 | 220 | 200 |
ST-GS2-045 | 180 | 45 | 37 | ST-GS2-250 | 1000 | 250 | 220 |
ST-GS2-055 | 230 | 55 | 45 | ST-GS2-280 | 1200 | 280 | 250 |
Model | Current (A) | Standard (kW) | Heavy load (kW) | Model | Current (A) | Standard (kW) | Heavy load (kW) |
ST-GS3-5d5 | 11 | 5.5 | 4 | ST-GS3-132 | 260 | 132 | 115 |
ST-GS3-7d5 | 15 | 7.5 | 5.5 | ST-GS3-160 | 320 | 160 | 132 |
ST-GS3-011 | 23 | 11 | 7.5 | ST-GS3-185 | 370 | 185 | 160 |
ST-GS3-015 | 30 | 15 | 11 | ST-GS3-200 | 400 | 200 | 185 |
ST-GS3-018 | 37 | 18.5 | 15 | ||||
ST-GS3-022 | 45 | 22 | 18.5 | ST-GS3-250 | 500 | 250 | 220 |
ST-GS3-030 | 60 | 30 | 22 | ST-GS3-280 | 560 | 280 | 250 |
ST-GS3-037 | 75 | 37 | 30 | ST-GS3-320 | 630 | 320 | 280 |
ST-GS3-045 | 90 | 45 | 37 | ST-GS3-355 | 710 | 355 | 320 |
ST-GS3-055 | 110 | 55 | 45 | ST-GS3-400 | 800 | 400 | 355 |
ST-GS3-075 | 150 | 75 | 55 | ST-GS3-450 | 900 | 450 | 400 |
ST-GS3-090 | 180 | 90 | 75 | ST-GS3-500 | 1000 | 500 | 450 |
ST-GS3-115 | 230 | 115 | 90 | ST-GS3-600 | 1200 | 600 | 500 |
Model | Current (A) | Matching motor power | Model | Current (A) | Matching motor power | ||
Standard (kW) | Heaavy load (kW) | Standard (kW) | Heaavy load (kW) | ||||
ST-GS4-5d5 | 11 | 5.5 | 4 | ST-GS4-132 | 260 | 132 | 115 |
ST-GS4-7d5 | 15 | 7.5 | 5.5 | ST-GS4-160 | 320 | 160 | 132 |
ST-GS4-011 | 23 | 11 | 7.5 | ST-GS4-185 | 370 | 185 | 160 |
ST-GS4-015 | 30 | 15 | 11 | ST-GS4-200 | 400 | 200 | 185 |
ST-GS4-018 | 37 | 18.5 | 15 | ST-GS4-250 | 500 | 250 | 200 |
ST-GS4-022 | 45 | 22 | 18.5 | ST-GS4-280 | 560 | 280 | 250 |
ST-GS4-030 | 60 | 30 | 22 | ST-GS4-320 | 630 | 320 | 280 |
ST-GS4-037 | 75 | 37 | 30 | ST-GS4-355 | 710 | 355 | 320 |
ST-GS4-045 | 90 | 45 | 37 | ST-GS4-400 | 800 | 400 | 355 |
ST-GS4-055 | 110 | 55 | 45 | ST-GS4-450 | 900 | 450 | 400 |
ST-GS4-075 | 150 | 75 | 55 | ST-GS4-500 | 1000 | 500 | 450 |
ST-GS4-090 | 180 | 90 | 75 | ST-GS4-600 | 1200 | 600 | 500 |
ST-GS4-115 | 230 | 115 | 90 |
Model | Rated power (KW) | Rated current (A) | Breaker (A) | By-pass contactor(A) | Cable size (mm2) |
XX-XX3-5d5 | 5.5 | 11 | 16 | 16 | 4 mm2 |
XX-XX3-7d5 | 7.5 | 15 | 20 | 16 | 4 mm2 |
XX-XX3-011 | 11 | 23 | 32 | 25 | 6 mm2 |
XX-XX3-015 | 15 | 30 | 40 | 40 | 10 mm2 |
XX-XX3-018 | 18 | 37 | 50 | 40 | 10 mm2 |
XX-XX3-022 | 22 | 43 | 63 | 63 | 16 mm2 |
XX-XX3-030 | 30 | 60 | 80 | 63 | 25 mm2 |
XX-XX3-037 | 37 | 75 | 100 | 100 | 35 mm2 |
XX-XX3-045 | 45 | 90 | 125 | 100 | 35 mm2 |
XX-XX3-055 | 55 | 110 | 160 | 160 | 35 mm2 |
XX-XX3-075 | 75 | 150 | 180 | 160 | 30×3 mm2 |
XX-XX3-090 | 90 | 180 | 225 | 250 | 30×3 mm2 |
XX-XX3-115 | 115 | 230 | 315 | 250 | 30×3 mm2 |
XX-XX3-132 | 132 | 264 | 315 | 400 | 30×4 mm2 |
XX-XX3-160 | 160 | 320 | 350 | 400 | 30×4 mm2 |
XX-XX3-185 | 185 | 370 | 400 | 400 | 30×4 mm2 |
XX-XX3-200 | 200 | 400 | 400 | 400 | 50×5 mm2 |
XX-XX3-250 | 250 | 500 | 630 | 630 | 50×5 mm2 |
XX-XX3-280 | 280 | 560 | 630 | 630 | 50×5 mm2 |
XX-XX3-320 | 320 | 640 | 630 | 630 | 50×5 mm2 |
XX-XX3-355 | 355 | 710 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-400 | 400 | 800 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-450 | 450 | 900 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-500 | 500 | 1000 | 1250 | 1000 | 80×6 mm2 |
XX-XX3-600 | 600 | 1200 | 1600 | 1600 | 80×6 mm2 |