Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant

China Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant, Find details about China Vpsa, Oxygen Gas Generator from Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant

Model NO.
HPO
Origin
China
Model NO.
HPO
Origin
China
VPSA oxygen plant
Equipment composition and description
1) Compressed air purification module
It is composed of high efficiency oil remover, freeze dryer, precision filter and activated carbon filter.
After passing through the air compressor, the air first enters the air buffer tank for buffering, then enters the high-efficiency oil remover to remove most of the impurities such as oil, water and dust, and then goes through the freezing-type dryer for further removing water, oil and dust through the precision filter, and finally enters the activated carbon filter for further removing oil.
Our specially designed activated carbon filter can be used to prevent the possible trace oil penetration to ensure the effective protection of the carbon molecular sieve and extend its service life. 
The compressed air treated by this purification part can be used for instrument air. 
2) Air buffer tank
It is composed of air buffer tank and accessory valve instrument.Air buffer tank is to reduce the flow pulsation, plays a buffering role: thus reducing the fluctuation of system pressure, so that compressed air can smoothly through the compressed air purification module in order to fully remove oil, water, dust and other impurities, reduce the oxygen and nitrogen separation system load.At the same time, it also provides a large amount of compressed air needed for rapid pressure boost in a short time for oxygen and nitrogen separation system when the adsorption tower is switched, which not only makes the pressure in the adsorption tower rise to the working pressure quickly, but also ensures the reliable and stable operation of the equipment. 
3) Oxygen and nitrogen separation system
It is composed of adsorption tower, compression device, auxiliary valve and instrument and electrical appliances.The adsorption tower designed with composite bed structure is divided into A and B towers, and the imported carbon molecular sieve is filled in the tower (the stretching and torsional vibration filling method is adopted to make the loading of carbon molecular sieve more uniform).Clean compressed air flows from the inlet end of Tower A to the outlet end through carbon molecular sieve at this time, O2, CO2 and H2O are adsorbed by it, and product nitrogen flows out from the outlet end of adsorption tower.After A period of time, the adsorption of carbon molecular sieve in Tower A will automatically stop before reaching saturation. Clean compressed air will flow into tower B to absorb oxygen and produce nitrogen, and the molecular sieve of Tower A will be regenerated.Molecular sieve regeneration is achieved by rapidly lowering the adsorption tower to O2, CO2 and H2O desorbed at atmospheric pressure.The two towers were regenerated alternately, that is, oxygen and nitrogen separation was completed and nitrogen was continuously produced.
4) Oxygen and nitrogen buffer system
It is composed of nitrogen buffer tank, precision filter, flowmeter, pressure regulating valve and vent parts.The nitrogen buffer tank is mainly used to balance the nitrogen pressure and purity separated from the nitrogen and oxygen separation system to ensure the stability of continuous nitrogen supply.At the same time, after the work switch of the adsorption tower, it recharges part of its gas into the adsorption tower. On the one hand, it helps the adsorption tower to boost pressure, and on the other hand, it also plays a role of protecting the bed, playing a very important process auxiliary role in the equipment's working process.Finally, it is filtered by precision filter to ensure the quality of nitrogen.

Main technical parameters
Oxygen Flow1~400Nm3/h
Purity25~95%
Pressure0.05~0.6MPa
Dew Point-60~-45ºC

Process flow chart
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant
* Air compressor system
Component of Compressed air purification
* Air buffer tank, Oxygen and nitrogen separation system
* Nitrogen buffering system

Principle of PSA oxygen production


Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen PlantAs shown in the figure above, zeolite molecular sieves have very different adsorption capacities for oxygen and nitrogen.Zeolite is a kind of material with a lot of micropores inside. The principle of psa is to use the difference of oxygen and nitrogen adsorption in zeolite micropores in the air under a certain pressure to achieve the purpose of oxygen and nitrogen separation.

Table of main technical parameters
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant

Application field of oxygen production equipment
When the pressure rises, zeolite molecular sieve absorbs nitrogen and produces oxygen. When the pressure drops to atmospheric pressure, zeolite molecular sieve desorbs nitrogen and regenerates.Psa oxygen production equipment usually has two adsorption tower, one absorb nitrogen to produce oxygen, the other denitrification regeneration, so alternate cycle continuously produce oxygen.
Treatment of gold industry: arc furnace iron rich oxygen, shaft furnace rich oxygen combustion.
Nonferrous metallurgy: lead smelting, copper smelting, zinc smelting, aluminum smelting, various furnace oxygen enrichment.
Environmental protection industry: drinking water treatment, wastewater treatment, pulp bleaching, sewage biochemical treatment.
Chemical industry: various oxidation reactions, ozone production, coal gasification.
Medical industry: oxygen bar, oxygen therapy, physical health care.
Aquaculture: Marine, freshwater aquaculture.
Other industries: fermentation, cutting, glass furnace, air conditioning, waste incineration.

Our Qualification & Locale photoes.
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant

FAQ       __                                                                                     _________________________________
Q: What is the terms of payment?
A: T/T, L/C etc.


Q: How long is your delivery time?
A: Generally it is 180-240 working days depending on your order.

Q: How to get a prompt quotation?
A: When you send us inquiry, please kindly tell us the below technical information.
1) N2 Flow rate: ____Nm3/h
2) N2 Purity: ____%
3) N2 Discharge pressure: ____Bar
4) Voltages and Frequency: _____V/PH/HZ
5) Application or use for which industry.

Q: What's the order process?
A:
1) Inquiry---provide us all clear requirements.
2) Quotation---official quotation form with all clear specifications.
3) Contract confirmation---provide correct contract details.
4) Payment terms--- T/T 30% in advanced, balanced before shipment.
5) Production---mass production g. Shipping--- by sea, air or courier. Detailed picture of package will be provided.
6) Installation and commissioning.

Q: Can you provide oversea service?
A: Yes, we could.


Contact US
Psa Oxygen Generator and Hospital Oxygen Generator Gas Manifold System for Medical Oxygen Plant