GDHG-206 CT/PT current and voltage transformers On-site Calibrator

China GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator, Find details about China CT/PT calibrator, CT/PT Analyzer from GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator

Model NO.
GDHG-206
Display
Digital
Control
Computer Control
Power Source
AC220V
CT Turns Ratio Range
5A/5A- 25000A/5A (5A/1A- 5000A/1A)
PT Turns Ratio Range
Full range measurement ±0.2%
Accuracy of PT/CT Error
±0.05%
CT Secondary Burden
1-25 ohm ±2%
PT Secondary Burden
1VA-500VA ±2%
Ratio Error
0.001%-3% (100V)
Angle Error
0.00′-50′ (100V)
Delivery Time
15-20 days
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan, China
HS Code
9030849000
Model NO.
GDHG-206
Display
Digital
Control
Computer Control
Power Source
AC220V
CT Turns Ratio Range
5A/5A- 25000A/5A (5A/1A- 5000A/1A)
PT Turns Ratio Range
Full range measurement ±0.2%
Accuracy of PT/CT Error
±0.05%
CT Secondary Burden
1-25 ohm ±2%
PT Secondary Burden
1VA-500VA ±2%
Ratio Error
0.001%-3% (100V)
Angle Error
0.00′-50′ (100V)
Delivery Time
15-20 days
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan, China
HS Code
9030849000

General introduction

GDHG-206 CT/PT On-site Calibrator is designed for analyzing current transformers and voltage transformers of ratio error, angle error, ratio error/angle error of 1%-200% current. It can directly measure turns ratio and polarity, actual secondary burden of CT/PT.
The model uses DC and AC power supply with high precision and automatic linear adjustment. High speed and reliable digital processing module is also adopted.


Similar model

GDPT-103 PT On-site Calibrator
GDPT-105 CT PT On-site Calibrator
GDPT-106B Transformer Comprehensive Tester 
GDPT-108A CT PT On-site Calibrator 
GDPT-201P CT PT On-site Calibrator 
 

Specifications

CT Turn Ratio Range5A/5A- 25000A/5A (5A/1A- 5000A/1A)
Turn ratio error ±0.2%
PT Turn Ratio RangeFull range measurement ±0.2%
Accuracy of PT, CT Error±0.05%
DC Resistance0.0-0.1ohm ±3%
0.1-50 ohm ±1%
CT Secondary Burden1 ohm -25ohm ±2%
PT Secondary Burden1VA-500VA ±2%
Ratio Error0.001%-3% (100V)
Angle Error0.00'-50' (100V)
Admittance0.1ms-99.9ms
ErrorX= ±(2%×X+2%×Y±2digit), Y= ±(2%×X+2%×Y±2digit)

Different types of CT/PT calibrator are available
GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator
GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator


GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator
GDHG-206 CT/PT   current  and voltage transformers On-site  Calibrator