China MPPT Solar Hybrid Charge Inverter 80A Controller Max 3500W Pure Sine Wave Inverter 48V 110V PV Volt 145V 50Hz 60Hz off-Grid, Find details about China Solar Inverter, Micro Inverter from MPPT Solar Hybrid Charge Inverter 80A Controller Max 3500W Pure Sine Wave Inverter 48V 110V PV Volt 145V 50Hz 60Hz off-Grid
MPPT Solar Hybrid Charge Inverter 80A Controller Max 3500W Pure Sine Wave Inverter 48V 110V PV Volt 145V 50Hz 60Hz Off-Grid
Overview:
HF series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard. Four charging modes are optional, i.e. Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging; and two output modes are available, i.e. Inverter and Mains, to meet different application requirements. The solar charging module applies the latest optimized MPPT technology to quickly track the maximum power point of the PV array in any environment and obtain the maximum energy of the solar panel in real time. Through a state of the art control algorithm, the AC-DC charging module realizes fully digital voltage and current double closed loop control, with high control precision in a small volume. Wide AC voltage input range and complete input/output protections are designed for stable and reliable battery charging and protection. Based on full-digital intelligent design, the DC-AC inverter module employs advanced SPWM technology and outputs pure sine wave to convert DC into AC. It is ideal for AC loads such as household appliances, power tools, industrial equipment, and electronic audio and video equipment. The product comes with a segment LCD display design which allows real-time display of the operating data and status of the system. Comprehensive electronic protections keep the entire system safer and more stable.
Feature:
1.Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave.
2.Two output modes: mains bypass and inverter output; uninterrupted power supply.
3.Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.
4.Advanced MPPT technology with an efficiency of 99.9%.
5.Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status.
6.ON/OFF rocker switch for AC output control.
7.Power saving mode available to reduce no-load loss.
8.Intelligent variable speed fan to efficiently dissipate heat and extend system life.
9.Lithium battery activation design, allowing access of lead-acid battery and lithium battery.
10.360 ° all-round protection with a number of protection functions.
11.Complete protections, including short circuit protection, over voltage and under voltage protection, overload protection, reverse protection, etc.
Models | HF4825U80 -145 | HF4830U80 -145 | HF4835U80 -145 |
AC mode | |||
Rated input voltage | 110/120Vac | ||
Input voltage range | (90Vac~140Vac)±2% | ||
Frequency | 50Hz/ 60Hz (Auto detection) | ||
Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); | ||
Overload/shor t circuit protection | Circuit breake | ||
Efficiency | >95% | ||
Conversion time (bypass and inverter) | 10ms (typical) | ||
AC reverse protection | Available | ||
Maximum bypass overload current | 40A | ||
Inverter mode | |||
Output voltage waveform | Pure sine wave | ||
Rated output power (VA) | 2500 | 3000 | 3500 |
Rated output power (W) | 2500 | 3000 | 3500 |
Power factor | 1 | ||
Rated output voltage (Vac) | 120Vac | ||
Output voltage error | ±5% | ||
Output frequency range (Hz) | 50Hz±0.3Hz 60Hz±0.3Hz | ||
Maximum Efficiency | >91% | ||
Overload protection | 102% < load <110%)±10%: report error and turn off the output after 5 minutes; (110% < load < 125%)±10%: report error and turn off the output after 10 seconds; (Load >125%±10%): report error and turn off the output after 5 seconds; | ||
Peak power | 4000VA | 4500VA | 5000VA |
Loaded motor capability | 1HP | 2HP | 2HP |
Rated battery input voltage | 48V (Minimum starting voltage 44V) | ||
Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen) | ||
Power saving mode selfconsumption | Load≤50W | ||
AC charging | |||
Battery type | Lead acid or lithium battery | ||
Maximum charge current(can be set) | 0-40A | ||
Charge current error | ±5Adc | ||
Charge voltage range | 40-60Vdc | ||
Short circuit protection | Circuit breaker and blown fuse | ||
Circuit breaker specifications | 40A | ||
Overcharge protection | Alarm and turn off charging after 1 minute | ||
PV charging | |||
Maximum PV open circuit voltage | 145Vdc | ||
PV operating voltage range | 60-145Vdc | ||
MPPT voltage range | 60-115Vdc | ||
Battery voltage range | 40-60Vdc | ||
Maximum output power | 4200W | ||
PV charging current range (can be set) | 0-80A | ||
Charging short circuit protection | Blown fuse | ||
Wiring protection | Reverse polarity protection | ||
Hybrid charging Max charger current specifications (AC charger+PV charger) | |||
Max charger current(can be set) | 0-120A | ||
Certified specifications | |||
Certification | CE(EN62109-1) | ||
EMC certification level | EN61000, C2 | ||
Operating temperature range | -15°C to 55°C | ||
Storage temperature range | -25°C ~ 60°C | ||
Humidity range | 5% to 95% (Conformal coating protection) | ||
Noise | ≤60dB | ||
Heat dissipation | Forced air cooling, variable speed of fan | ||
Communicatio n interface | USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control | ||
Size (L*W*D) | 426mm*322mm*124mm | ||
Weight (kg) | 11.8 |