1/3ml Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE Material

China 1/3ml Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE Material, Find details about China Pasteur Tubes, Lab Consumable from 1/3ml Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE Material

Model NO.
30-0135 30-0135A1 30-0138 30-0138A1 30-0238A1
Trademark
Biologix
Specification
1ml 3ml
Origin
Changzhou, Jiangsu, China
Model NO.
30-0135 30-0135A1 30-0138 30-0138A1 30-0238A1
Trademark
Biologix
Specification
1ml 3ml
Origin
Changzhou, Jiangsu, China

1/3ml  Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE Material
 

Features
 

1. Polyethylene pipettes will not shatter or break

2. An excellent alternative to Pasteur pipettes and rubber bulbs

Evenly distributed thickness ensures uniform suction force

3. Gamma radiation sterilized option available

4. Available wrapped individually (sterile) or in bulk package (non-sterile)


 

1/3ml Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE Material

 

 

Ordering Information
 
Cat #LengthGraduated ToSterilePackageUnit
30-0135

162.0mm

1mlNOBulk500 Pieces/Pack, 4 Packs/Case
30-0135A1162.0mm1mlYESIndividually Wrapped500 Pieces/Pack, 4 Packs/Case
30-0138162.0mm3mlNOBulk500 Pieces/Pack, 4 Packs/Case
30-0138A1162.0mm3mlYESIndividually Wrapped500 Pieces/Pack, 4 Packs/Case
30-0238A1183.0mm3mlYESIndividually Wrapped500 Pieces/Pack, 4 Packs/Case

engthGraduated ToSterilePackageUni

1/3ml Disposable Laboratory Liquid Handling Transfer Pipets with Pasteur Pipettes Moded Graduation Marks PE MaterialWhat are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.