PCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free Thermocyclers

China PCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free Thermocyclers, Find details about China High Quality Medical Grade Polypropylene, Fits Most Standard Thermocyclers from PCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free Thermocyclers

Model NO.
60-0056
Design
Alphanumeric Well
Other
PCR Plates
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Model NO.
60-0056
Design
Alphanumeric Well
Other
PCR Plates
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

PCR Plates

Features

Made of high quality medical grade polypropylene
Ultra-thin tube walls with uniform thickness for accelerated heat transfer, shorter cycle times, and more consistent results
Alphanumeric well labeling for convenient identification
DNase, RNase, and endotoxin free

Specifications

Fits most standard thermocycler
Can withstand centrifugation of up to 6,000 RCF
 

PCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free Thermocyclers
Ordering Information
 
Cat #WellSkirtColorSterileUnit
60-005696-wellHalf-SkirtedClearNO25/Pack, 100/Case

 


PCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free ThermocyclersPCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free ThermocyclersPCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free ThermocyclersPCR Plates Semi-Skirted 96-Well Dnase, Rnase, and Endotoxin Free Thermocyclers1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.