1.Output RS-485, 4-20mA
2.Power supply 24VDC, 1A
3.Clamp-on encapsulated IP 67 sensors require no pipe cutting, no plant shut-down, are a hygenic measurement leading to lower installation and labor costs
4.Lightweight (0.7 kg; 1.5 lb) PC/ABS IP 65 transmitter
5.Accuracy ±1.5% FS
6.Repeatability ± 0.3%
7.Mount and play
8.No need to break the pipe
9.No adjustment needed
10.Multi-outputs optional
11.LCD display, 16 (4 x 4) keyboard with 20 x 2 line display
12.Fluid: Water
13.Pipe material: PVC
14.Protecting rate: IP54
15.Wide bi-directional Flow range from 0.1 m/s to 6m/s
16.One meter for a wide range of pipe sizes from 0.8 inch to1.44 inches (20mm to 63 mm)
17.Configurable pulse and relay output
Descriptions:
Flexmeter XK-JH10K mount and play ultrasonic flow meter delivers easy installation and require no pipe cutting, thereby reducing installation and labor costs. Incorporating the core technologies of U-ideal XK-JH10K, the design of the U-ideal universal transit-time flow meter is focused on those features that optimize the measurement of water flows in HVAC, irrigation, and other water applications.
Ideal for pipes up to 63mm in diameter, the XK-JH10K promises accuracy to ±1.5%FS, repeatability of ±0.3% of reading and a temperature range of 32oF to 140o F (0oC to 60oC).
The XK-JH10K offers low power consumption at a very competitive price. An easy to read display and clear, user-friendly menu selections make using the instrument simple and convenient. It can be configured via a 4x4 keypad without additional programming devices and features a 20 x 2 digit alpha-numeric display.
Specifications: |
Main Unit | Repeatability | ±0.3% |
Accuracy | ±1.5% FS |
Velocity | 0.1 to 6m/s |
Display | 16 (4×4) key with push buttons |
Units | English (U.S.) or metric |
Output | Analog: 4 to 20mA current loop (max load 750 Ω) Digital output: RS 485 |
Enclosure | IP 65 (PC/ABS) |
Liquids | Liquid Types | Virtually all commonly used liquids (full pipe) |
Liquid Temp | -40C ~ 155C, depending on transducer type |
Suspension concentration | < 20,000ppm. Particle or air bubble size should not exceed 75um |
Pipe | Pipe Size | 15mm to 300mm |
Pipe Material | PVC. |
Environment | Temperature | Transducer: -40C ~ 80C for the standard version; -40C ~ 155C for the higher temperature version |
Humidity | Up to 99% RH, (non-condensing). |
Power | 24 VDC |