48/60/72/96V 60A Lithium AGM Battery Charging MPPT Solar Charger Controller
Product overviewMPPT controller uses the maximum power point tracking technology to extract the maximum power from the solar array to charge the battery.
Maximum power point tracking mode is completely automatic and does not require user adjustment .
When the maximum power point of the array varies with environmental conditions, the controller automatically tracks the maximum power point of the array to ensure that the maximum energy of the day can be obtained from the solar array .
Main features* Excellent heat dissipation design and Intelligent controlled cooling fan.
* Innovative maximum power point tracking technology, the conversion rate of up to 97%.
* Quick scan of the entire I-V curve , Efficient track the maximum power point.
* Three types of lead-acid battery, sealed, colloid, open type battery and
* lithium battery series charging procedures are optional.
* With the functions of over charge, over discharge, overload and short circuit automatic protection.
*With RS485 communication interface, It can communicate with multiple and the upper computers,which is convenient to check the operating parameters of the controller.Technical Data: Model:MP-40/50/60 60 | 40A | 50A | 60A |
Charging Mode | MPPT Automatic Maximum Power Point Tracking |
Charging Method | Three stages : Constant Current (MPPT), Balanced Charging, Floating Charge |
System Type | 48/60/72/96(V) | Automatic Identification/Manual Setting |
System Identification Voltage Range | 48V System | DC36-DC60V |
60V System | Manual setting |
72V System | Manual setting |
96V System | DC72-DC96V |
Soft Start Time | 48/60/72/96(V) | <10s |
Recovery Time | 48/60/72/96(V) | <500us |
Static Power | 48/60/72/96(V) | <2W |
Machine Efficiency | 48/60/72/96(V) | >96.5% |
PV Utilization | 48/60/72/96(V) | 99.97% |
MPPT Operating Voltage Range | 48V System | DC65-DC150V |
60V System | DC72-DC150V |
72V System | DC80-DC150V |
96V System | DC130-DC180V |
Limit Input Voltage | 48/60/72/96(V) | 48/60/72(160V)/96V(235V) |
Overvoltage Protection | 48/60/72/96(V) | 48/60/72(150V)/96V(230V) |
Overvoltage Recovery | 48/60/72/96(V) | 48/60/72(145V)/96V(225V) |
Maximum Solar Panel Input Power | 48V System | 2100W | 2650W | 3150W |
60V System | 2650W | 3300W | 4000W |
72V System | 3200W | 4000W | 4800W |
96V System | 4250W | 5300W | 6400W |
Optional Battery Type (Default is lead-acid battery) | 48/60/72/96(V) | Lead-acid maintenance-free Battery, Gel Battery, Liquid Battery, Lithium Battery (Can also be customized for other types of battery) |
Application for Solar Power System :Safety Packing :FAQQ1: MOQA: MOQ from our company is required 1 unit
Q2: Are you manufacturer or trading company?A: We are professional manufacturer since 2004
Q3:I need this product and wanna a system for family/industrial/commerical using, can you help me? A: Yes, we have a professional technology team average 10 years' experience, they can design solar power system in accordance with customers' special requirements.
Q4: How long is your delivery timeA: Within 15 days
Q5:How about your after-sales service?A:Our quality warranty for 2 years; any parts will be shipped for free during warranty period.