China Gel/AGM/VRLA Lead-Acid Storage Battery Testing/Pulse Desulfation/Activation Capacity Restoring Battery Regeneration Equipment, Find details about China Battery Reconditioner, Battery Reconditioning Equipment from Gel/AGM/VRLA Lead-Acid Storage Battery Testing/Pulse Desulfation/Activation Capacity Restoring Battery Regeneration Equipment
Model No.: | DK-GN50 |
Total Channel Number: | 50 Channels |
Pulse Repair Channels: | 24 Channel |
Capacity Test Channels: | 24 Channels |
HF Activating Repair Channels: | 2 Channels |
Power Supply: | AC 220V±10% 50 Hz |
Power: | No-load 620 W, Full-loading 7 KW |
Power Factor: | 0.85 |
Pulse Repair | |
Waveform: | 8330 Hz Square wave |
Pulse Edge: | ≤20ns |
Duty Ratio: | Adjustable |
Max. Output Average Current: | ≥0.8A |
Charge-DischargeTesting | |
Max. Discharge Current: | 20A(0.5-20A) adjustable |
Max. Charge Current: | 10A (0.5-10A) adjustable |
Min. discharge final voltage: | Can be adjusted to 2V |
Max. charge voltage: | Can be adjusted to 23V |
HF Activating Repair Channels | |
Pulse Frequency: | 15 kHz |
Max. Peak Current: | 200A |
Average Value of Output Current: | 0-10A Constant current adjustable |
Max. Average Current: | ≥10A |