Vertical Return Air Floor Mounted Air Conditioning Fan Coil
1. Vertical exposed fan coil features:
(1)Low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Flexible installation; (5) Easy operation.
In central air conditioner system, Eurostars vertical exposed floor standing fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.
2. Vertical exposed floor standing fan coil unit nomenclature
ES T 200 VE2 T R A O
1 2 3 4 5 6 7 8
1: ES Eurostars
2 :T Terminal series
3 :200 Rated air flow: CFM
4 :VE2 Ceiling exposed floor mounted and the number of tube system
5 :T Coil type: T-2C0H (Note: C-Cold water coil; H-Hot water coil)
6 :R Connection pipe direction: R-Right (face to air outlet) L-Left (face to air outlet)
7: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
8 :O Sales region: O-Other regions; C-Mainland China
3. Eurostars vertical exposed fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Universal Exposed Fan Coil Unit(2 pipe system) |
Model EST | 200HE2 | 300HE2 | 400HE2 | 500HE2 | 600HE2 | 800HE2 | 1000HE2 | 1200HE2 | 1400HE2 |
200VE2 | 300VE2 | 400VE2 | 500VE2 | 600VE2 | 800VE2 | 1000VE2 | 1200VE2 | 1400VE2 |
Power supply | 220V/1PH/50HZ |
Air flow (m3/h) | H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
M | 260 | 390 | 510 | 640 | 770 | 1020 | 1280 | 1530 | 1790 |
L | 170 | 260 | 340 | 430 | 510 | 680 | 850 | 1020 | 1190 |
Cooling capacity | TH | H | W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH | W | 1368 | 2052 | 2736 | 3420 | 4103 | 5471 | 6839 | 8207 | 9575 |
TH | M | W | 1494 | 2242 | 2989 | 3736 | 4483 | 5978 | 7472 | 8967 | 10461 |
SH | W | 1181 | 1771 | 2362 | 2952 | 3541 | 4722 | 5903 | 7084 | 8265 |
TH | L | W | 1162 | 1744 | 2325 | 2906 | 3487 | 4649 | 5812 | 6974 | 8136 |
SH | W | 953 | 1430 | 1907 | 2383 | 2860 | 3813 | 4765 | 5718 | 6672 |
Heating capacity | H | W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
M | W | 2131 | 3197 | 4262 | 5328 | 6393 | 8524 | 10655 | 12786 | 14917 |
L | W | 1675 | 2511 | 3349 | 4186 | 5024 | 6697 | 8372 | 10046 | 11721 |
Noise | H | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 51 |
Power input | H | W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 |
Water flow | H | m³/h | 0.31 | 0.46 | 0.62 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 |
Water resistance | kPa | 16 | 18 | 20 | 23 | 28 | 30 | 33 | 37 | 40 |
Pipe | Inlet water pipe | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" |
Outlet water pipe | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" |
Coil | type | Hydrophilic aluminum fin arounds high efficient copper pipe |
Working pressure | MPa | 1.6 |
Condensation water pipe | mm | ¢16 |
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates |
Qty | 1 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 |
Motor | Type | Single-phase capacitive motor equips with fine ball bearing, low noise and long service life |
Qty | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature 60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.
4. Vertical exposed fan coil unit correction factor
(1)Capacity correction factor at different condition:
Working Condition | Hot water inlet temp. |
| Air inlet DB Temp. | 40ºC | 50ºC | 60ºC | 70ºC |
|
Return air | 17 | ºC | 0.58 | 0.82 | 1.11 | 1.40 |
|
18 | ºC | 0.56 | 0.80 | 1.09 | 1.37 |
|
19 | ºC | 0.54 | 0.77 | 1.06 | 1.34 |
|
20 | ºC | 0.51 | 0.74 | 1.03 | 1.32 |
|
21 | ºC | 0.48 | 0.71 | 1.00 | 1.29 |
|
22 | ºC | 0.45 | 0.68 | 0.97 | 1.26 |
|
23 | ºC | 0.42 | 0.65 | 0.94 | 1.23 |
|
24 | ºC | 0.39 | 0.62 | 0.91 | 1.20 |
|
(2)Cooling capacity correction factor:
Model EST | 200HE2 | 300HE2 | 400HE2 | 500HE2 | 600HE2 | 800HE2 | 1000HE2 | 1200HE2 | 1400HE2 |
200VE2 | 300VE2 | 400VE2 | 500VE2 | 600VE2 | 800VE2 | 1000VE2 | 1200VE2 | 1400VE2 |
Medium | Total Heat | 0.83 | 0.83 | 0.83 | 0.83 | 0.83 | 0.83 | 0.83 | 0.83 | 0.83 |
Low | Total Heat | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 |
(3)Heating capacity correction factor:
Model EST | 200HE2 | 300HE2 | 400HE2 | 500HE2 | 600HE2 | 800HE2 | 1000HE2 | 1200HE2 | 1400HE2 |
200VE2 | 300VE2 | 400VE2 | 500VE2 | 600VE2 | 800VE2 | 1000VE2 | 1200VE2 | 1400VE2 |
Medium | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 |
Low | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 |
5.Vertical floor fan coil unit quotation remarks
(1)Packing: Standard export package
(2)Delivery Day: 10~25 working days after deposit is confirmed
(3)Delivery term: CIF,FOB or CNF EX-Work are welcomed
(4)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
Or 100% Irrevocable non-transferred LC at sight
(5)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
(6)Validity: 20 days
(7)Payment currency: USD