Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p

China Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p, Find details about China Contactor, AC Contactor from Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p

Model NO.
LC1
Trademark
CNC
Origin
China
Model NO.
LC1
Trademark
CNC
Origin
China

 CJX2-09(LC1-D0901) AC Magnetic Contactor

Product Description

Application
     CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced  according to IEC 60947-4, GB14048-4.
Standard control voltage

Voltage50Hz60Hz50/60Hz
24B5B6B7
42D5D6D7
48E5E6E7
110F5F6F7
220M5M6M7
230P5-P7
240U5U6U7
380Q5Q6Q7
400V5-V7
415N5-N7
440R5R6R7
500S5--
660Y5--

Specification

Type  CJX2-09CJX2-12CJX2-18CJX2-25CJX2-32CJX2-40CJX2-50CJX2-65CJX2-80CJX2-95
Rated insulation voltage(Ui) V690
Rated thermal current(Ith) A20203240506080809595
Rated operation current(Ie)AC-3,380VA9121825324050658095
AC-3,660VA66891218213439424955
AC-4,380VA3.557.78.51218.524283741
AC-4,660VA1.523.84.47.59121417.321.3
MAX.power of 3 phase motor controlled AC-3,220VkW2.2345.57.5111518.52225
AC-3,380VkW45.57.5111518.522303745
AC-3,660VkW5.57.5101518.53033374555
Electrical lifeAC-310000t100808060
AC-410000t20201510
Mechanical life 10000t1000800800600
Operation frequencyAC-3t/h1200600600600
AC-4t/h300300300300
Matching fuse type  RT16-20RT16-20RT16-32RT16-40RT16-50RT16-63RT16-80RT16-80RT16-100RT16-125
Matching thermal relay type  JR28-25JR28-25JR28-25JR28-25JR28-36JR28-93JR28-93JR28-93JR28-93JR28-93
Wiring capacity mm²1.51.52.5461016162535
Coil   
Control power voltage(Us)ACV36,110,127,220,380
Allowwed control circuit voltageCloseV85%~110%Us
OpenV20%~75%Us(AC)
 CloseVA70110200
KeepingVA81120
Loss powerW1..8~2.73~46~10
Auxiliary contact   
Rated thermal current(Ith) A10
Rated  operation voltage(Ue)AC-15V380
DC-13V220
Rated control capacityAC-15VA360
DC-13W33

About Us 
Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p

Our Advantage 
Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p
About Packing
Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p