China Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p, Find details about China Contactor, AC Contactor from Electrical Magnetic Contactor AC Contactor 9A to 115A 3p 4p
CJX2-09(LC1-D0901) AC Magnetic Contactor
Application
CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4, GB14048-4.
Standard control voltage
Voltage | 50Hz | 60Hz | 50/60Hz |
24 | B5 | B6 | B7 |
42 | D5 | D6 | D7 |
48 | E5 | E6 | E7 |
110 | F5 | F6 | F7 |
220 | M5 | M6 | M7 |
230 | P5 | - | P7 |
240 | U5 | U6 | U7 |
380 | Q5 | Q6 | Q7 |
400 | V5 | - | V7 |
415 | N5 | - | N7 |
440 | R5 | R6 | R7 |
500 | S5 | - | - |
660 | Y5 | - | - |
Specification
Type | CJX2-09 | CJX2-12 | CJX2-18 | CJX2-25 | CJX2-32 | CJX2-40 | CJX2-50 | CJX2-65 | CJX2-80 | CJX2-95 | ||
Rated insulation voltage(Ui) | V | 690 | ||||||||||
Rated thermal current(Ith) | A | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 95 | 95 | |
Rated operation current(Ie) | AC-3,380V | A | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC-3,660V | A | 66 | 89 | 12 | 18 | 21 | 34 | 39 | 42 | 49 | 55 | |
AC-4,380V | A | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 41 | |
AC-4,660V | A | 1.5 | 2 | 3.8 | 4.4 | 7.5 | 9 | 12 | 14 | 17.3 | 21.3 | |
MAX.power of 3 phase motor controlled | AC-3,220V | kW | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
AC-3,380V | kW | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
AC-3,660V | kW | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 | |
Electrical life | AC-3 | 10000t | 100 | 80 | 80 | 60 | ||||||
AC-4 | 10000t | 20 | 20 | 15 | 10 | |||||||
Mechanical life | 10000t | 1000 | 800 | 800 | 600 | |||||||
Operation frequency | AC-3 | t/h | 1200 | 600 | 600 | 600 | ||||||
AC-4 | t/h | 300 | 300 | 300 | 300 | |||||||
Matching fuse type | RT16-20 | RT16-20 | RT16-32 | RT16-40 | RT16-50 | RT16-63 | RT16-80 | RT16-80 | RT16-100 | RT16-125 | ||
Matching thermal relay type | JR28-25 | JR28-25 | JR28-25 | JR28-25 | JR28-36 | JR28-93 | JR28-93 | JR28-93 | JR28-93 | JR28-93 | ||
Wiring capacity | mm² | 1.5 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 16 | 25 | 35 | |
Coil | ||||||||||||
Control power voltage(Us) | AC | V | 36,110,127,220,380 | |||||||||
Allowwed control circuit voltage | Close | V | 85%~110%Us | |||||||||
Open | V | 20%~75%Us(AC) | ||||||||||
Close | VA | 70 | 110 | 200 | ||||||||
Keeping | VA | 8 | 11 | 20 | ||||||||
Loss power | W | 1..8~2.7 | 3~4 | 6~10 | ||||||||
Auxiliary contact | ||||||||||||
Rated thermal current(Ith) | A | 10 | ||||||||||
Rated operation voltage(Ue) | AC-15 | V | 380 | |||||||||
DC-13 | V | 220 | ||||||||||
Rated control capacity | AC-15 | VA | 360 | |||||||||
DC-13 | W | 33 |