Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer

China Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer, Find details about China Spectrometer Portable, Lab Spectrophotometer from Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer

Model NO.
FGGDJ-LG-F930/F930A-A
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Customized
Product Model
F93/F93A
Product Name
Biometer Biobase Good Single Beam Fluorescence Wi
Display Mode
4 Digits LED
Bandwidth
12nm
Emission Monochromator
360~650nm (C-T Diffraction Grating)
Wavelength Accuracy
±2nm
Dimension
450*420*280mm
Product Standard
Enterprise Standard Q/Seek3
Sensitivity
1*10-9 G/Ml
Interface
RS232 Serial Port
Weight(Kg)
7(N) 9(G)
Trademark
BIOMETER
Transport Package
Wooden Box
Specification
450*420*280mm
Origin
Shandong
HS Code
9031809090
Model NO.
FGGDJ-LG-F930/F930A-A
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Customized
Product Model
F93/F93A
Product Name
Biometer Biobase Good Single Beam Fluorescence Wi
Display Mode
4 Digits LED
Bandwidth
12nm
Emission Monochromator
360~650nm (C-T Diffraction Grating)
Wavelength Accuracy
±2nm
Dimension
450*420*280mm
Product Standard
Enterprise Standard Q/Seek3
Sensitivity
1*10-9 G/Ml
Interface
RS232 Serial Port
Weight(Kg)
7(N) 9(G)
Trademark
BIOMETER
Transport Package
Wooden Box
Specification
450*420*280mm
Origin
Shandong
HS Code
9031809090
Product Description


Instrument Features:
Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer

1.The emission monochromator adopts 1200 line diffraction grating. Its large aperture and non-spherical reflecting mirrors produces extra high sensitivity;

2.EX light uses LED,match with the central wavelength of 365nm (F93A set includes 365nm,376nm,392nm,405nm). The system can be replaced by customer,Carry on the maintenance expediently & can satisfy more choices and demand. LED is a cold-light source with longevity,lower background & reliability,prevent from thermo-pollution;

3.Automatic zero adjustment and automatic background subtraction;Eight stage sensitivity adjustment;Real time fluorescence reading display and concentration print out,Extra wide dynamic range of fluorescence reading,accurate measurement of minute changes in samples;

4.RS-232C serial port interface attached,after option Data Processing Software Package it is convenient to store record & transmit data & draw up a standard operating curve;

5.Quality fine,less weight & measure,test simply,particularly suitable for Education & Lab.

Product Parameters
 
                   Item                                                         Details
             Light source
 
                                                            LED
                                                         F93: 365nm
                                  F93A Sets:365nm,376nm,392nm,405nm
             Bandwidth                                                             12nm
                    The wavelength of LED can be selected within 360-600nm
 Emission monochromator                                    360~650nm  (C-T diffraction grating)
   Wavelength accuracy                                                              ±2nm  
  Wavelength repeatability                                                              ≤1nm
            Sensitivity                                                        1×10-9  g/ml
      Linearity deviation                                                              ≤±3.0%
  Variation of power source                                                220V±22V  50Hz±1Hz
              Interface                                                    RS232 serial port
               Printer                                            Serial printer/Jet printer(for PC)

Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer


 
Latest News

Biometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer

Company Profile

Biometer Biobase Good Single Beam Fluorescence with Flameout Protection SpectrophotometerBiometer Biobase Good Single Beam Fluorescence with Flameout Protection Spectrophotometer

 

 

FAQ

1.Why choose BIOMETER?
We are a good manufactuer and reliable trading company in lab furniture and lab equipment,  Offer OEM & ODM service. 
2.How about the sample of our product?
We could send you the samples but the freight and the sample are charged.
3.How about Biometer payment term?
T/T & L/C &Western Union etc(40% deposit, the balance before shipment).
4.How about delivery time?
Within 7-15 workdays after receiving deposit.
5.What is the shipping port?
FOB to Qingdao Port,China(Also can ship according to customers' requests).
6.How about the package?
Bubble film + Cotton +Standard export wooden case.
7.How to inspect the goods?
Products will be checked by our QC staff frist, then our project manager.
Client can come and check by themselves or third partycheck is available.