12V 40ah Rechargeable Safe and Maintenance Free UPS Battery

China 12V 40ah Rechargeable Safe and Maintenance Free UPS Battery, Find details about China Battery, Lead Acid Battery from 12V 40ah Rechargeable Safe and Maintenance Free UPS Battery

Model NO.
KPT40-12
Installation
Packaged
Rechargeable
Chargeable
Approx Weight
13kg
Unit/Carton
1
Carton Dimension
235*145*235mm
Trademark
kptgu
Transport Package
Carton/ Pallet
Specification
230*138*207mm
Origin
China
Model NO.
KPT40-12
Installation
Packaged
Rechargeable
Chargeable
Approx Weight
13kg
Unit/Carton
1
Carton Dimension
235*145*235mm
Trademark
kptgu
Transport Package
Carton/ Pallet
Specification
230*138*207mm
Origin
China
                    12V 40ah Rechargeable Safe and Maintenance Free UPS Battery


12V 40ah Rechargeable Safe and Maintenance Free UPS Battery
Specification Type
Model NO.VoltsCapacity(AH)Approx Dimension(mm)Approx Weight(kg)Unit/carton(pcs)Carton Dimension(mm)
20hrs rateL*W*H
12V7AH127151*65*952.110353*320*130
12V12AH1212151*99*953.68415*315*120
12V15AH1215181*76*16754365*179*210
12V16AH1216165*125*17562263*176*198
12V17AH1217181*76*16764365*179*210
12V19AH1219165*125*1756.82263*176*198
12V23AH1223197*166*171102345*205*210
12V24AH1224165*125*17582263*176*198
12V32AH1232197*166*171112345*205*210
12V33AH1233195*130*15592275*208*202
12V34AH1234350*166*173151365*179*210
12V38AH1238197*166*171122345*205*210
12V39AH1239329*172*216181350*186*265
12V40AH1240230*138*207131235*145*235
12V42AH1242350*166*17316.71365*179*210
12V43AH1243329*172*216201350*186*265
12V52AH1252350*166*17318.21365*179*210
12V53AH1253329*172*216211350*186*265
12V55AH1255230*138*207151235*145*235
12V62AH1262329*172*216221350*186*265
12V65AH1265350*166*173201365*179*210
12V70AH1270260*168*210211270*178*245
12V73AH1273406*173*237261420*186*270
12V82AH1282406*173*237281420*186*270
12V95AH1295406*173*237301420*186*270
12V100AH12100329*172*216291350*186*265
12V105AH12105406*173*237311420*186*270
12V112AH12112406*173*237321420*186*270
12V120AH12120406*173*237331420*186*270
12V115AH12115483*170*239361496*183*273
12V130AH12130483*170*239381496*183*273
12V150AH12150483*170*239411496*183*273
12V147AH12147522*239*218471535*253*278
12V160AH12160522*239*218491535*253*278
12V175AH12175522*239*218521535*253*278
12V184AH12184522*239*218541535*253*278
12V190AH12190522*239*218551535*253*278
12V200AH12200522*239*218561535*253*278
12V 40ah Rechargeable Safe and Maintenance Free UPS Battery12V 40ah Rechargeable Safe and Maintenance Free UPS Battery
Battery connection

Only batteries or battery packs with the same actual capacity can be used in series.
The connection part shall be tight to prevent sparks; in case of poor contact, the contact surtace can be cleaned with soda water.Only batteries or battery groups with the same actual voltage can be used in parallel,
The positive and negative poles shall not be reversed or short circuited.
The batteries of the battery pack shall be separated by more than 10 mm to facllitate heat dissipation.

Battery charging
Floating charge (limit voltage, control current) use: charging voltage 2.20-2.30V single cell (25 C).
When trickle current is used, the floating charge current of the battery is adjusted to less than 2mAl ah;
Temperature compensation, the temperature compensation coefficient of each monomer is 3MV c.(based on20 'ºC)
Cyclic use (stop when fully charged, charge when fully discharged):charging voltage 2.35-2.45v single call maximum power.The flow shall not be greater than 25%of the nominal capacity;
Note:the battery shall not be used in closed or high temperatdre environment, and shall be kept away from the fire source.

Storage and installation
1.For batteries not put into use, the connecting wire shall be removed, the pole sheath shall be covered and wiped clean;
2.Maintain and charge the battery every three months. T he charging method is limited current and constant voltageMethod: the initial charging current is 0.1CA, and the charging volltage is 24V single cell (at 25 c);
3.The battery shall be stored in a dry and ventilated place, away from direct sunlight and heat source.
4.When handling the battery, the force shall be even, and the stress part is the shell artof the batfery to avoid damaging the pole;
5.Insulating tools shall be used during installation to prevent electric shock.

Points to note

1.When the batlery is discharged from the factory. do not attempt to disassemble the battery to avoid danger .if the battery shells damaged accidentally ln case of contact with sulfuric acid, please wash with plenty of clear water immediately, and see a doctor immediatly if necessary
2.Do not mix the old and new batteries;
3.Do not use battery in sealed container;
4.The battery shall have a complete resume , including factory date, installation date, operation record, etc;
5.Regularly (once a year) check whether the connecting wire is loose. lf it is loose, fasten it;
6.Wipe the battery regularly (once every three months) with soft fabric to keep the battery clean;
7.Do not use organic solvents to clean the battery.
8.Pay attention to the battery spacing to prevent salt bridge.
12V 40ah Rechargeable Safe and Maintenance Free UPS Battery12V 40ah Rechargeable Safe and Maintenance Free UPS Battery12V 40ah Rechargeable Safe and Maintenance Free UPS Battery
 
 
12V 40ah Rechargeable Safe and Maintenance Free UPS Battery