MODEL | DR-30-5 | DR-30-12 | DR-30-15 | DR-30-24 | |
DC VOLTAGE | 5V | 12V | 15V | 24V | |
RATED CURRENT | 3A | 2A | 2A | 1.5A | |
CURRENT RANGE | 0-3A | 0-2A | 0-2A | 0-1.5A | |
RATED POWER | 15W | 24W | 30W | 36W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
OUTPUT | VOLTAGE ADJ. RANGE | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 100ms, 30ms/230VAC 100ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 100ms/230VAC 21 ms/115VAC at full load | ||||
VOLTAGE RANGE | 85 ~ 264VAC 120-370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
INPUT | EFFICIENCY (Typ.) | 74% | 81% | 82% | 83% |
AC CURRENT (Typ.) | 0.88A/115VAC 0.48A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 15A/115VAC,30A/230VAC | ||||
OVERLOAD | 105 -160% rated output power | ||||
PROTECTION | Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVERVOLTAGE | 5.75-6.75V | 13.8-16.2V | 17.25-20.25V | 27.6 -32.4V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
WORKING TEMP. | -20 ~ +60"C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 - 90% RH non-condensing | ||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85"C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/"C (0 ~ 50'C) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved, Design refer to EN50178 | ||||
SAFETY & | WITHSTAND VOLTAGE | l/P-0/P:3KVAC | |||
EMC | ISOLATION RESISTANCE | l/P-0/P:100M Ohms / 500VDC / 25'C/ 70% RH | |||
(Note 4) | EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
MTBF | 441,5K hrs min. MIL-HDBK-217F (25'C) | ||||
OTHERS | DIMENSION | 78*93*56mm (W*H*D) | |||
PACKING | 0.27Kg; 48pcs/14Kg/1.02CUFT | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 "c of ambient temperature. | |||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
3.Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||||