Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards

China Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards, Find details about China Full Scale Room Test Chamber, Full Scale Room Fire Tester from Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards

Model NO.
AIC-9705
Weight of Chamber
7500kg
Weight of Controller
130kg
Transmittance Filters
0%, 25%, 50%, 75%, 100%
Dimension of Internal Room
3.6m X 2.4m X 2.4m
Delivery Time
2 or 3 Months
Gate Size
0.8m (W) X2.0m (H)
Trademark
AI
Transport Package
Plywood Case
Specification
Stainless steel
Origin
China
HS Code
9031809090
Model NO.
AIC-9705
Weight of Chamber
7500kg
Weight of Controller
130kg
Transmittance Filters
0%, 25%, 50%, 75%, 100%
Dimension of Internal Room
3.6m X 2.4m X 2.4m
Delivery Time
2 or 3 Months
Gate Size
0.8m (W) X2.0m (H)
Trademark
AI
Transport Package
Plywood Case
Specification
Stainless steel
Origin
China
HS Code
9031809090
Products:
According to ISO 9705 of building materials fire prevention performance standards, this fire test machine control platform provides independent gas analysis, including heat release rate and other related test required for related instruments, such as paramagnetic oxygen sensor, CO2/CO measuring instrument, He-Ni laser smoke density measurement and control system, etc.
Full-scale room fire test methods for surfaceof the article use the same principle with the cone calorimeter and SBI test method that is based on the oxygen consumption. The method is to simulate the corner of the fire scene as a standard testconditions, and installation of a test sample entirely according to actual use, the test results apply only to specific sample installation, it is one of the most reliable standard test methods. In the corner fire test, in accordance with the requirements of ISO 9705, and the measured material mounted on the inner walls of the room (at the top is not installed).Using propane burners as a radiation source, the measurement of heat release rate, temperature, heat release, flashover time, CO2 /CO and other parameters, for which the most important is the heat release rate and the flashover time. 
 
Standard:
• ISO 9705: Large Box test surface of the product
• ISO 13784-1: plywood building systems Reaction to fire test
• ASTM E 1537: Standard upholstered furniture flame test method
• ASTM E 603: Standard guidance corner combustion experiments

Main features:

1.The test room is built by the density of 700kg / m³-A1 class fireproof material.

2.The internal dimensions of the room 3.6M X 2.4M X 2.4M

3.The gate size: 0.8M (W) X2.0M (H)

4.Sandbox burner with propane gas and equipped with emergency shut-off devices.

5.Full Scale Room Fire Test Chamber adopts automatic ignition system to automatically record experimental data;

6.Independently movabletimetto display units.

7.10kV spark ignition, a cease-fire with safety devices. Fire extinguishing drainage system design.

8.The full scale room fire test machine is equipped withstaircasefor easy maintenance exhaust pipes.

 

Gas sampling and analysis system

1, Gas sampling system includes an annular sampler probe, suction pump, particulate filter, a cold trap, exhaust valve, water filters and CO2 filter.
2, Full Scale Room Fire Tester is supplied with three filters; Minimum filtration accuracy is 0.5um.
3, Freezing cold trap; air-conditioning compressor refrigeration systems; controlling the temperature in 0 ~ 5ºC.
4, Suction pump,Flowrate is 33L/min,vacuumis 700mmHg, and pressure is 2.5 bar.
5, Full Scale Room Fire Test Equipment has drying cylinder, which filter the water and impurities.
6, The flow controller to control the inspiratoryair flow.
7, The sampler has 12 holes and gas flow in the opposite direction, these holds built-in dust filter and 685mm from hoods.
8, Paramagnetic oxygen analyzer, the range is 0-25%; linear response; imported Britain Servomex oxygen sensor.

 

Smoke system

1, 0.5W HE-NE laser source.
2, Thorlabs optically detector.
3,Motor driven 5 class automatically calibration device with of 0%, 25%, 50%, 75%, 100% transmittance filters.
4,One touch calibration system in software with digital and curve display.


DAQ system

1, 16bit data acquisition module.
2, Digital communication between computer and DAQ module.
3, Labview based application software on DAQ and data analysis.

 

Operating system

1, Labview based application system,easilyand precise to operate and control.
2, Test status, calibration status display onscreen.
3, Device status are displayed on screen and indicators onpanel.
4, Transducers data, process parameters, test result displayed onscreenvia digital and curve.
5, Test and calibration procedure auto executed byPLCprogram.
6, Full Scale Room Fire Testing Equipment can be controlled via both application screen and control panel.
7, PC and PLC communicate with digital protocol which is safe and robust.

 

Technical Specifications

1,Paramagnetic oxygen analyzer, the concentration range is 0~25%, an oxygen analyzer islinearresponse, Britain Servomex oxygen sensor; 10% to 90% response time of less than 12s; output noise does not exceed 50ppm;.Reproduce the measured values lower than 100ppm,
2, Infrared CO2 analyzer range: 0 to 10%;accuracyof ± 0.01%;
3, The compressor works: cold trap: 0 to 5 degrees;
4, Full Scale Room Fire Test Machine uses imported diaphragm pump, flow rate: 33 l / min
5, The standard detector color accuracy ± 5%, output linearity (transmission) <1%, absolute permeability <1%;

 


Test Data

1, Heat Release Rate (HRR),
2, Total Heat Release (THR),
3, Efficiency Heat Release (EHR),
4, Smoke Production Rate (SPR),
5, Time to Ignite (TTI),
6, Time to flameout,
7, Oxygen Consumption Rate,
8, CO2 Production Rate,
9, CO Production Rate(optional)


 
Specification:
Size11,725(W)x4,000(D)x4,750(H)mm
Controller Size600(W)×750(D)×1800(H)mm
Power supplyAC 220V, 50/60Hz, 15A (control), AC 380V, 60Hz, 50A(drive)
WeightAbout 7,500kg(Cabinet), 130kg(Controller)
ExhaustMinimum 3.5m2/s(Measuring), Minimum 300m2/min(Exhaust)
Other requirementsCO(0.8%)/CO2(8%), Compressed gas, Vacuum cleaners, Computers, Propane gas, Heptane gas, Nitrogen

 


Factory overview
Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards

Customer Feedback 

Germany
Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards
USA
Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards
Transporation
Full-Scale Indoor Fire Test Device That Complies with ISO 13784-1 and ISO 9705 Standards