Rsxy-B CT PT Integrated Analyzer with 0.5% Measurement Accuracy of Turn Ratio

China Rsxy-B CT PT Integrated Analyzer with 0.5% Measurement Accuracy of Turn Ratio, Find details about China CT Analyzer, PT Analyzer from Rsxy-B CT PT Integrated Analyzer with 0.5% Measurement Accuracy of Turn Ratio

Model NO.
RSXY-B
Application
Industrial
Customized
Customized
Power Supply
AC220V±10%,50Hz
Device Output
0~1000vrms,5arms(20A Peak Value)
Large Current Output
0~600A
Excitation Accuracy
≤0.5%(0.2%*Reading+0.3%*Range)
CT Ratio Measurement
≤25000A/5A(5000A/1A),≤0.5%
PT Ratio Measurment
≤500kv,≤0.5%
Trademark
RISING
Transport Package
Wooden
Specification
410mm × 260mm × 340mm
Origin
China
HS Code
9030849000
Model NO.
RSXY-B
Application
Industrial
Customized
Customized
Power Supply
AC220V±10%,50Hz
Device Output
0~1000vrms,5arms(20A Peak Value)
Large Current Output
0~600A
Excitation Accuracy
≤0.5%(0.2%*Reading+0.3%*Range)
CT Ratio Measurement
≤25000A/5A(5000A/1A),≤0.5%
PT Ratio Measurment
≤500kv,≤0.5%
Trademark
RISING
Transport Package
Wooden
Specification
410mm × 260mm × 340mm
Origin
China
HS Code
9030849000

Product Introduction

RSXY-B is designed for automatic test of protection and metering transformer,which is suitable for both laboratory and field test.

Product Features

1.Support the detection of CT and PT.
2.All the test items can be completed by a single machine without external auxiliary equipment.
3.Equipped with micro fast printer, it can directly print test results on site.
4.Intelligent controller, easy to operate.
5.Large screen LCD, graphical display interface.
6.Automatically calculate the inflection point value of CT/PT (excitation) according to the regulation.
7.Automatically display 5% and 10% error curve.
8.It can save 3000 groups of test data, which won't be lost after power failure.
9.Equipped with USB interface,which tansfer test data.
10.Small and light, less than 22kg,very convenient for field test.

Test abilities

CT(Protection,metering)PT
Volt ampere characteristic (excitation characteristic) curveVolt ampere characteristic (excitation characteristic) curve
Inflection point valueInflection point value
5% and 10% error curveTurn ratio measurement
Turn ratio measurementPolarity judgment
Polarity judgmentAC withstan voltage test
Primary current injecting test Core demagnetization
AC withstan voltage test 
Core demagnetization 

Technical parameters

Power supplyAC220V±10%,50Hz
Device output0~1000Vrms,5Arms(20A peak value)
Note:0~5A(True value),5A~20A(Calculated value)
Large current output0~600A
Excitation accuracy≤0.5%(0.2%*reading+0.3%*range)
CT ratio measurementRange≤25000A/5A(5000A/1A)
Accuracy≤0.5%
PT ratio measurmentRange≤500KV
Accuracy≤0.5%
Working conditionTemperature:-10ºC~40ºC,HR:≤90%,Altitude:≤1000m
Size and weightSize:410mm × 260mm × 340mm,weight:≤22Kg

Rsxy-B CT PT Integrated Analyzer with 0.5% Measurement Accuracy of Turn Ratio