All New Aluminium Alloy Conductor

China All New Aluminium Alloy Conductor, Find details about China Power Cable, Bare Conductor from All New Aluminium Alloy Conductor

Model NO.
AAAC
Brand
Jiapu
Standard
ASTM, IEC, DIN, CSA, BS...
Trademark
JP
Transport Package
Export Wooden Drum or Wooden Steel Drum
Origin
China
HS Code
7614900000
Model NO.
AAAC
Brand
Jiapu
Standard
ASTM, IEC, DIN, CSA, BS...
Trademark
JP
Transport Package
Export Wooden Drum or Wooden Steel Drum
Origin
China
HS Code
7614900000
All New Aluminium Alloy Conductor
Specifications
Aluminum alloy bare stranded conductor 
1. overhead power line transmission 
2. various voltage levels 
3. fast delivery
AAAC Steel cored aluminium alloy stranded conductor
1. Standard: BS EN50182,ASTM B398, ASTM B399,  BS 3242 DIN 48201, CSA C49, NFC 34-125
 
2.Specification: AAAC are composed by bare concentric-lay-stranded aluminum alloy wires.
 
3. Application: AAAC are used in overhead electric power transmission and distribution lines.
 
4.AAAC Construction and Specification for your reference
 
Nominal Cross-sectional Area (mm2)Numbers/Diameter
(mm)
Calculated Cross-sectional Area (mm2)Overall Diameter
(mm)
Max. D.C Resistance
(Ω/km)
CalculatedBreaking Load
(N)
Calculated Weight
(kg/km)
Min. Delivery Length
(m)
Current
(A)
167/1.7015.895.101.802284043.54000111
257/2.1525.416.451.127435569.63000147
357/2.5034.367.500.8382576094.12000180
507/3.0049.489.000.57867930135.51500227
707/3.6071.2510.800.401810950195.11250284
957/4.1695.1412.480.300914450260.51250338
12019/2.85121.2114.250.237319420333.51250390
15019/3.15148.0715.750.194323310407.41250454
18519/3.50182.8017.500.157428440503.01000518
21019/3.75209.8518.750.137132260577.41000575
24019/4.00238.7620.000.120536260656.91000610
30037/3.20297.8322.400.0968946850820.41000707
40037/3.70397.8325.900.072476115010971000851
50037/4.16502.9029.120.057337637013871000982
63061/3.63631.3032.670.045779194017448001140
80061/4.10805.3636.900.0358811590022558001340
 
Item
L.p.
Opis
Rated data/Technical parameters
Jednostka
Unit
Wartość
Value
 
 
AlMgSi stranded compacted conductor
 
1.
Producent
Manufacturer
 
-
 
 
 
2.
Wykonano zgodnie z
Manufacturer according to
  
EN 60228
 
3.
Oznaczenie przewodu
Conductor identification
 
-
 
50
 
54,6
 
95
 
4.
Nominalna średnica przewodu
Nominal conductor diameter
 
mm
 
7,85 - 8,20
 
9,20 - 9,55
 
11,4±0,3
 
5.
Nominalny przekrój przewodu
Nominal cross-section
2 
50
 
54,6
 
95
 
6.
Liczba drutów (konstrukcja)
Number of wires
szt.
psc
 
1+6
7.Kierunek skrętu poszczególnych warstw
Direction of each layer
 
-
 
(Z)
 
8.
Obliczeniowy moduł sprężystości wzdłużnej
(końcowy) przewodu
Calculated elastic modulus (final) of the conductor
 
N/mm2
 
60 000
 
9.
Obliczeniowy współczynnik wydłużenia cieplnego
przewodu
Calculated thermal elongation coefficient of the conductor
 
× 10-6 K-1
 
23,00
10.Max. rezystancja DC 1 km przewodu w temp. 20 ˚C
Max.  DC resistance of 1 km of conductor at 20 ˚C
 
Ω/km
 
0,72
 
0,63
 
0,363
 
11.
Min znamionowa wytrzymałość przewodu na
rozciąganie RTS
Min. rated tensile strength of the conductor (RTS) (breaking force)
 
 
kN
 
 
14,2
 
 
16,6
 
 
27,9
12.Przybliżona masa 1 km przewodu
Approx. weight of 1 km of conductor
 
kg/km
 
130,03
 
165,8
 
248,28
 
5.Workshop
All New Aluminium Alloy Conductor