D118I Modbus High Accuracy Fixed Flowmeter

China D118I Modbus High Accuracy Fixed Flowmeter, Find details about China Flow Meter, Ultrasonic Flow Meter from D118I Modbus High Accuracy Fixed Flowmeter

Model NO.
D118i
Measuring Media
Liquid
Measuring Principle
Transit Time
Certification
CE, ISO
Flow Range
0.03 ~ ±40FT/S (0.01~ ±12 M/S)
Installation Method
Wall Mount
Repeatability
0.1% of Measured Value
Display
4.7 Inch TFT LCD, Touch Button, Humanized Design
Analog Output
4~20mA, Maximum 750Ω
Pulse Output
0~9999Hz, Oct Output, (Adjustable)
Realy Output
: The Highest 1Hz,(1A@125VAC or 2A@30VDC)
Communication
RS232&RS485 Communication Interface, Support Modbu
TF Card
Max Record:4GB, Working 1200 Days
Power Supply
90 to 250 VAC, 48 to 63 Hz. or 10 to 36VDC
Keypad
24 Light Tactile Keys
Temperature Transmitter
-10ºC~60ºC
Temperature Transducer
-40ºC~80ºC
Humidity
up to 99% Rh,Non-Condensing
Transmitter
Die-Cast Aluminum,IP65,CNC Machined
Trademark
pFlow
Origin
China
HS Code
9026100000
Model NO.
D118i
Measuring Media
Liquid
Measuring Principle
Transit Time
Certification
CE, ISO
Flow Range
0.03 ~ ±40FT/S (0.01~ ±12 M/S)
Installation Method
Wall Mount
Repeatability
0.1% of Measured Value
Display
4.7 Inch TFT LCD, Touch Button, Humanized Design
Analog Output
4~20mA, Maximum 750Ω
Pulse Output
0~9999Hz, Oct Output, (Adjustable)
Realy Output
: The Highest 1Hz,(1A@125VAC or 2A@30VDC)
Communication
RS232&RS485 Communication Interface, Support Modbu
TF Card
Max Record:4GB, Working 1200 Days
Power Supply
90 to 250 VAC, 48 to 63 Hz. or 10 to 36VDC
Keypad
24 Light Tactile Keys
Temperature Transmitter
-10ºC~60ºC
Temperature Transducer
-40ºC~80ºC
Humidity
up to 99% Rh,Non-Condensing
Transmitter
Die-Cast Aluminum,IP65,CNC Machined
Trademark
pFlow
Origin
China
HS Code
9026100000
D118i Modbus High Accuracy Fixed Flowmeter

Ultrasonic flow meters that use transit-time methods to measure flow.

Introduction
D118i is an advanced flow meter, which applies our patented PICOFLOY technology, with ultra-high accuracy, linearity, and repeatability, and meets the high measurement accuracy requirements of users.

Main Features
  1. Measuring Range: 0.01 to 12m/s
  2. Accuracy: 0.5% 
  3. Bi-direction flow measurement
  4. Suitable for lined or unlined metal and plastic pipes

Applications
Clamp-on flow measurement of drinking water, process water, sea water, demineralized water, wastewater, and tolerant of liquids with small amounts of air bubbles or suspended solids.

Specifications
PERFORMANCE SPECIFICATIONS
 
Flow range±0.03ft/s ~ ±40ft/s 0.01m/s ~ ±12m/s)
Accuracy±0.5% of measured value (for ±1.5ft/s40ft/s)
Repeatability0.1% of measured value
Pipe size1"to 200" (25mm to 5000mm)
FUNCTION SPECIFICATIONS
OutputsAnalog output: 4~20mA, maximum 750Ω.
Pulse output: 0~9999Hz, OCT output, (adjustable)
Realy output: the highest 1Hz,(1A@125VAC or 2A@30VDC)
CommunicationRS232&RS485 Communication Interface, Support Modbus Protocol
SD CardMax record:4GB, working 1200 days ( sample frequency 5 second ) Storage time interval:1~13000s
Power supply90 to 245 VAC, 48 to 63 Hz. Or 10 to 36VDC
Keypad24 light tactile keys
Display4.7 inch TFT color screen
TemperatureTransmitter:-40ºF~140ºF(-40ºC~60ºC)
Transducer:-40ºF~176ºF(-40ºC~80ºC,standard)
HumidityUp to 99% RH,non-condensing
PHYSICAL SPECIFICATIONS
TransmitterDie-cast aluminum,IP65,CNC machined
TransducerEncapsulated design, protection grade IP68
The standard length of cable: 9m
Material: 304 stainless steel
WeightTransmitter: 1kg

Interface and Size


D118I Modbus High Accuracy Fixed Flowmeter
Questions & Answers
Q: Can we use our label/brand?
A: yes, Gentos offer OEM/Labeling service.

Q: What is the express?
A: Usually by air.

Q: Is sample unit available?
A: Yes, customer can get sample unit with a great discount.