China Power Inverter with Low Frequency Transfomer in-Built Inverter Charger, Find details about China DC to AC Inverter, AC Inverter from Power Inverter with Low Frequency Transfomer in-Built Inverter Charger
MODEL | EP30-1KW | EP30-1.5KW | EP30-2KW | EP30-3KW | EP30-4KW | EP30-5KW | EP30-6KW | |||||||||
Default Battery System Voltage | 12V | 24V | 12V | 24V | 12V | 24V | 12V | 24V | 48V | 24V | 48V | 24V | 48V | 24V | 48V | |
INVERTER OUTPUT | Reted Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | ||||||||
Surge Rating (20ms) | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||||||
Capable Of Starting Electric Motor | 1HP | 2HP | 3HP | |||||||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC | 220V/230V/240VAC | ||||||||||||||
Output Voltage Regulation | ±10% RMS | |||||||||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | |||||||||||||||
Inverter Efficiency(Peak) | >88% | |||||||||||||||
Line Mode Efficiency | >95% | |||||||||||||||
Power Factor | 1.0 | |||||||||||||||
Typical Transfer Time | 10ms(max) | |||||||||||||||
AC INPUT | Voltage | 120VAC/230VAC | ||||||||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | 155~280VAC(For Computers) | ||||||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||||||||||
BATTERY | Minimum Start Voltage | 10.OVDC/10.5VDC for12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||||||||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||||||
Idle Consumption-Search Mode | <25W when power saver on | |||||||||||||||
CHARGER | Output Voltage | Depends on battery type | ||||||||||||||
Charger AC Input Breaker Rrating | 10A | 30A | 40A | |||||||||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 65A | 35A | 75A | 45A | 30A | 65A | 35A | 70A | 40A | 75A | 50A | |
BTS | Continuous Output Power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||||||||||||||
BYPASS & PROTECTION | Input Voltage Waveform | Sine wave (grid or generator) | ||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||||||||
Bypass Breaker Rating | 10A | 30A | 40A | |||||||||||||
Max Bypass Current | 10Amp | 30Amp | 40Amp | |||||||||||||
MECHANICAL SPECIFICATIONS | Mounting | Wall mount | ||||||||||||||
Dimensions (W*H*D) | 185*160*423 | 185*160*600 | ||||||||||||||
Net Weight (kg) | 15.7 | 18 | 16.2 | 15.5 | 20.3 | 19.1 | 25.3 | 23.7 | 24 | 37.2 | 34.8 | 44.2 | 44 | 44.2 | 44 | |
Shipping Dimensions(W*H*D) | 315*300*570 | 319*288*755 | ||||||||||||||
Shipping Weight (kg) | 18.3 | 20.6 | 19 | 18.1 | 23.1 | 21.8 | 28.1 | 26.5 | 26.5 | 40.8 | 38.4 | 48 | 47.8 | 48 | 47.8 | |
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||||||||||
Storage Temperature | -15°C to 60°C | |||||||||||||||
Audible Noise | 60dB MAX | |||||||||||||||
Display | LED+LCD | |||||||||||||||
Standard Warranty | 1 year |