Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement

China Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement, Find details about China Sensor, Dissolved Ozone sensor from Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement

Model NO.
CS6530D
Type
Concentration Meter
Materials
Plastic
Function
Water quality testing and analysis
Power
12VDC
Output
RS485 MODBUS RTU
Measure material
Potentiostatic
Housing material
Glass+POM
Waterproof grade
IP68
Measurement range
0-2mg/L;0-10mg/L;0-20mg/L
Accuracy
+/- 1%F.S
Temperature compensation
NTC10K
Installation thread
PG13.5
Trademark
Twinno
Transport Package
1 PCS/Carton
Specification
Double Platinum Ring
Origin
Shanghai, China
HS Code
9027
Model NO.
CS6530D
Type
Concentration Meter
Materials
Plastic
Function
Water quality testing and analysis
Power
12VDC
Output
RS485 MODBUS RTU
Measure material
Potentiostatic
Housing material
Glass+POM
Waterproof grade
IP68
Measurement range
0-2mg/L;0-10mg/L;0-20mg/L
Accuracy
+/- 1%F.S
Temperature compensation
NTC10K
Installation thread
PG13.5
Trademark
Twinno
Transport Package
1 PCS/Carton
Specification
Double Platinum Ring
Origin
Shanghai, China
HS Code
9027
CS6530D Digital Dissolved Ozone Sensor


Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement







Electrode principle characteristics:

Constant voltage principle electrode is used to measure Dissolved Ozone or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The Dissolved Ozone or hypochlorous acid in the water sample flowing through the measuring electrode will be consumed. Therefore, the water sample must be kept flowing continuously through the measuring electrode during measurement.

The constant voltage measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement.




The constant voltage electrode has a simple structure and a glass appearance. The front end of the online residual Dissolved Ozone is a glass bulb, which is easy to clean and replace. When measuring, it is necessary to ensure that the water flow rate through the Dissolved Ozone measuring electrode is stable.

Dissolved Ozone or hypochlorous acid. This product is a digital sensor that integrates electronic circuits and microprocessors inside the sensor, referred to as digital electrode.

Constant voltage residual chlorine digital electrode sensor (RS-485) Features

1. Power supply and output isolation design to ensure electrical safety

2. Built-in protection circuit for power supply and communication chip, strong anti-interference ability

3. With comprehensive protection circuit design, it can work reliably without additional isolation equipment

4. The circuit is built inside the electrode, which has good environmental tolerance and easier installation and operation

5. RS-485 transmission interface, MODBUS-RTU communication protocol, two-way communication, can receive remote commands

6. The communication protocol is simple and practical and extremely convenient to use

7. Output more electrode diagnostic information, more intelligent

8. The internal integrated memory can still memorize the stored calibration and setting information after power off

9. POM shell, strong corrosion resistance, PG13.5 thread, easy to install.




Application:
Drinking water: ensuring reliable disinfection
Food: to ensure food safety, sanitary bag and bottle methods
Public works: detection of residual chlorine
Pool water: efficient disinfectant
 
No additional instrument is required, 485 signal transmission, no interference on site, easy to integrate into various systems, and effectively reduce related use costs.
The electrodes can be calibrated in the office or laboratory, and replaced directly on site, without additional on-site calibration, which greatly facilitates later maintenance
Calibration information record is stored in electrode memory.




 
Model No.CS6530D
Power/Outlet12VDC/RS485 MODBUS RTU
Measurement methodPotentiostatic
Housing materialGlass+POM
Waterproof ratingIP68
Measurement range0-2mg/L;0-10mg/L;0-20mg/L
Accuracy±1%F.S
Pressure resistance≤0.3Mpa
Temperature compensationNTC10K
Temperature range0-80ºC
Measuring/Storage Temperature0-45ºC
CalibrationSample calibration, standard liquid calibration
Connection methods4 core cable
Cable lengthStandard 5m cable, can be extended to 100m
Installation threadPG13.5
Application Drink water, pool water, etc.


After Sales Service

* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.



FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.

What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.

How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.



Delivery and Packing:

Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement


Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement



Our company:

Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement
     Digital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid MeasurementDigital RS485 Dissolved Ozone Sensor for O3 Disinfectant Fluid Measurement