Phase Sequence Power Factor Tester Clamp Current Tester

China Phase Sequence Power Factor Tester Clamp Current Tester, Find details about China Dual Clamp Digital Phase Meter, Digital Phase Meter from Phase Sequence Power Factor Tester Clamp Current Tester

Model NO.
EP8420
Display
Digital
Control
Computer Control
Weight
550g
Power Source
DC9V Alkaline Dry Batteries
Function
Directly Test Phase, AC Current, AC Voltage, AC Le
Power Supply
DC9V Alkaline Dry Batteries
Power Consumption
Nearly 5mA If Backlight off
LCD Display
Blue Screen with Backlight Design
LCD Size
70mm*62mm
LCD Display Field
64mm*54mm
Jaw Size
Phi7.5mm*13mm
Sampling Rate
Nearly 3 Times/Second
Length of Test Wire
1.5m
Line Length of Current Clamp
2m
Operating Temperature and Humidity
-10degree~40degree,80%Rh and Less
Storage Temperature and Humidity
-10degree~60degree,70%Rh and Less
Input Impedance
Input Impedance of Tested Voltages: 2mohm
Withstand Voltage
2000V/50Hz Sine Wave a.C. Current for One Minute
Structure
Double Insulation
Trademark
EP Hipot Electric
Transport Package
Caron or Plywood Case
Specification
196mm*92mm*54mm
Origin
China
HS Code
9030320000
Model NO.
EP8420
Display
Digital
Control
Computer Control
Weight
550g
Power Source
DC9V Alkaline Dry Batteries
Function
Directly Test Phase, AC Current, AC Voltage, AC Le
Power Supply
DC9V Alkaline Dry Batteries
Power Consumption
Nearly 5mA If Backlight off
LCD Display
Blue Screen with Backlight Design
LCD Size
70mm*62mm
LCD Display Field
64mm*54mm
Jaw Size
Phi7.5mm*13mm
Sampling Rate
Nearly 3 Times/Second
Length of Test Wire
1.5m
Line Length of Current Clamp
2m
Operating Temperature and Humidity
-10degree~40degree,80%Rh and Less
Storage Temperature and Humidity
-10degree~60degree,70%Rh and Less
Input Impedance
Input Impedance of Tested Voltages: 2mohm
Withstand Voltage
2000V/50Hz Sine Wave a.C. Current for One Minute
Structure
Double Insulation
Trademark
EP Hipot Electric
Transport Package
Caron or Plywood Case
Specification
196mm*92mm*54mm
Origin
China
HS Code
9030320000
General Information:
EP8420 Dual-clamp digital phase meter is a multi-functional instrument developed specially for on-site test. Featured with high precision, good stability, less power consumption and easy operation, it measures directly A.C. voltage and A.C. current even when the tested circuit is not opened, as well as phase between two voltages, two currents and the voltage-current. In addition, it measures indirectly power factor and power of the circuit, identifies three-phase sequence, wiring group, inductive and capacitive circuit of transformer, tests secondary circuit and the busbar differential protection system, tells the phase relation between different CT groups of differential protection, examines whether the wiring of watt-hour meter is correct, and checks and repairs circuit equipment, etc. The instrument has huge LCD screen, with letters reaching 40mm in height and looks greatly clear thanks to the backlight design. The instrument is applicable to electricity, petrochemical engineering, metallurgy, railway, meteorology, industrial and mining enterprises, academic institutions, colleges and metrological sectors, etc.

Technical Specifications

Reference Conditions and Operating Conditions
Influence FactorsReference ConditionsOperating ConditionsRemarks
Ambient environment23ºC±1ºC-10ºC~40ºC 
Ambient humidity40%~60%<80% 
Signal waveformSine waveSine waveβ=0.05
Signal frequency50HZ±1HZ45HZ~65HZ 
Working voltage9V±0.1V9V±1V 
Phase current range applicable1A±0.1A10mA~20.0A 
Phase voltage range applicable100V±10V30V~600V 
External electric field and magnetic fieldShall be avoided
Location of tested wireThe tested wire is located in approximate geometric center of the clamp jaw


General Specifications
 FunctionDirectly test phase, A.C. current, A.C. voltage, A.C. leak current, and phase sequence; identify grouping, inductive, and capacitive circuit of transformer; and indirectly test power factor and power.
Power SupplyDC9V alkaline dry batteries (1.5V AA×6)
Power ConsumptionNearly 35mA at the maximum if backlight on, batteries work continuously for nearly 40 hours.
Nearly 5mA if backlight off, batteries work continuously for 300 hours.
 DisplayLCD display, blue screen with backlight design, applicable to dark places.
 LCD Size70mm×62mm
LCD Display Field64mm×54mm
 Instrument Size(L x W x H): 196mm×92mm×54mm
 Jaw Size:φ7.5mm×13mm
 Sampling RateNearly 3 times/second
RangeA.C Voltage: 0~20V/200V/600V
A.C Current: 0~200mA/2A/20A
Phase: 0~360°
Range of tested signal during phase measuringWhen measuring phase U1-U2: 30V~600V
When measuring phase I1-I2: 10mA~20.00A
When measuring U1-I2 or I1-U2: 10V~600V, 10mA~20.00A
Data-holdPress HOLD to hold data during test, and DH displays.
Auto power-offThe instrument shut off automatically in 15min after startup so that to reduce battery consumption.
Voltage testWhen the battery voltage is less than 7.2v, the low voltage symbol appears, reminding to replace the battery.
Mass of instrumentThe body is nearly 550g (battery included), the clamp is nearly 170g x2, and the test wire is nearly 250g.
Length of test wire1.5m
Line length of current clamp2m
Operating temperature and humidity-10ºC~40ºC; 80%Rh and less
Storage temperature and humidity-10ºC~60ºC; 70%Rh and less
Input impedanceInput impedance of tested voltages: 2MΩ
Input impedance of voltage when testing phases U1U2: 40kΩ
Withstand voltageWithstand voltage between upper cover of the instrument and bolt on battery cover place is 2000V/50Hz sine wave A.C. current for one minute.
InsulationInsulation between wires and the shell of instrument and insulation between two voltage input ends ≥10MΩ.
StructureDouble insulation

Basic Errors and Performance Indexes under Reference Conditions
CategoryRangeResolutionBasic Error
Voltage20V0.01V±(1.2%rdg+2dgt)
200V0.1V
500V1V
Current200mA0.1mA±(1.0%rdg+2dgt)
2A1mA
10A10mA
Phase0~360°±1°

Please contact EP Hipot Electric for more details on China Portable China Portable Dual Clamp Digital Phase Meter EP8420.


Phase Sequence Power Factor Tester Clamp Current Tester
Phase Sequence Power Factor Tester Clamp Current Tester
Phase Sequence Power Factor Tester Clamp Current Tester
Phase Sequence Power Factor Tester Clamp Current Tester
Phase Sequence Power Factor Tester Clamp Current Tester