Industrial Use 3 Phase UPS 15kVA 20kVA 30kVA 40kVA Online UPS Uninterrupted Power Supply (UPS)

China Industrial Use 3 Phase UPS 15kVA 20kVA 30kVA 40kVA Online UPS Uninterrupted Power Supply (UPS), Find details about China Online UPS, High Frequency UPS from Industrial Use 3 Phase UPS 15kVA 20kVA 30kVA 40kVA Online UPS Uninterrupted Power Supply (UPS)

Model NO.
DPH3/3 100KVA
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Daopulse
Input Frequency Range
46~54Hz or 56~64Hz
Line-Bat Transfer
0ms
Efficiency
> 94%
Weight
225kg/60kg
Trademark
Daopulse
Transport Package
Standard Exporting Packing
Specification
790*360*1010mm
Origin
Guangzhou, China-Mainland
HS Code
8504402000
Model NO.
DPH3/3 100KVA
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Daopulse
Input Frequency Range
46~54Hz or 56~64Hz
Line-Bat Transfer
0ms
Efficiency
> 94%
Weight
225kg/60kg
Trademark
Daopulse
Transport Package
Standard Exporting Packing
Specification
790*360*1010mm
Origin
Guangzhou, China-Mainland
HS Code
8504402000
Industrial use 3 phase ups 15kva 20kva 30kva 40kva online UPS uninterrupted power supply 

Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 VAC --240 VAC, 40 -- 70 Hz.
· 0ms Line-Bat transfer, ensure the safety and reliability of load. 
· ECO mode optional, reduce the  UPS power consumption. 
· Low audible noise (below 50 dB), will not affect your daily life. 


Specfictations 
Model30K40K60K80K100K120K160K200K
PhaseThree phase in--Three phase out
Input
Rate capacity30KVA/27KW40KVA/36KW60KVA/54KW80KVA/72KW100KVA/90KW120KVA/108KW160KVA/144KW200KVA/180KW
Rate voltage400VAC(three phase with ground)
Turn on voltage range 190-520VAC(three phase)  ≤50% load208-478VAC(three phase)  ≤70% load
305-478VAC(three phase)  ≤100% load305-478VAC(three phase)  ≤100% load
Frequency range46~54Hz or 56~64Hz40~70Hz
Output
Rate voltage380/400/415VAC(three phase)  ±1%
Line mode frequency46~54Hz or 56~64Hz
Bat mode frequency50Hz or 60Hz
Voltage harmonic≤2%   R load;       ≤4%   RCD load
Crest ration3:01
Line-Bat transfer0ms
INV-Bypass transfer0ms
Over load (Line mode)100%~110%:10min;110%~130%:1min;100%~110%:1H;110%~125%:10min;125%~150%:1min;load>150%:200ms; 
( transfer to bypass and alarm)
load>130%:1s; ( transfer to bypass and alarm)
Over load (BAT mode)100%~110%:30s;110%~130%:10s;load >130%:1s; 
 ( transfer to bypass and alarm)
Frequency
Line mode> 94%
Bat mode> 93%
Bat
Number32~40(adjustable)
Charger voltage+/-13.7VDC×BAT NO.
Charge current (stand)2A(only 32 BAT)No
Charge current (long)1A/2A/3A/4A can be set2A/4A/6A/8A can be set24A32A40A48A
Size(length*width*height)and weight
Standard UPS(mm)815*300*1000No
Weight(kg)225250
Long time UPS(mm)815*300*1000790*360*1010940*567*10151040*567*1452
Weight(kg)6061108113199234306340
Environment
Work temperature0ºC~40ºC
Work humidity20%~95%
Audible noise≤60dB≤70dB≤75dB≤70dB≤73dB
CommunicationRS-232/USB/SNMP card
Industrial Use 3 Phase UPS 15kVA 20kVA 30kVA 40kVA Online UPS Uninterrupted Power Supply (UPS)