Product Description
Instruction:
iS10 is a High Acuity 10.4" Multi-Parameter Modular Patient Monitor, which can offer multiple parameter modules to choose from, adapting to the flexible parameter combination requirements in high acuity applications. With its plug-and-play modules, our modular patient monitor is able to monitor a wide range of parameters simultaneously, such as ECG, RESP, SpO2, NIBP, 2 TEMP, IBP, EtCO2, BIS, EEG, CO, ICG, AG etc adapting from critical cares to anesthesia monitoring.
Feature:
3/5 Lead ECG,HR,Resp,NIBP,SpO2,PR,2-Temp
Main Unit: iS10: 10.4" TFT-LCD Display, 2 standard Module slot, Touch Screen,1 RJ45 Ethernet Socket,1 Defibrillation Output,1 Nurse Call Socket,1 VGA Port,2 USB 1.1 Port,1 Lithium Rechargeable Battery
Option:
Option Module:Sidesteam EtCO2 Module,MicroStream EtCO2 Module,MainStream EtCO2 Module,AG Module,C.O. Module,IBP Module,Temp Module,Nellcor SpO2 Module,Masino SpO2 Module,SunTech NIBP module
Printing:3 Channel Thermal Recorder
Mounting:Rolling Stand,Wall Mount
Battery:11.1V/4.0AH Rechargeable Lithium Battery
Other Options:External Display,Wireless Lan,Extensive Memory Card ,Analog Output(ECG or IBP)
Standard Configuration:
3/5 Lead ECG, HR, Resp, NIBP, SpO2, PR, 2-Temp
Main Unit:
iS10 Express: 10.4" TFT-LCD Display,
2 standard Module slot,Touch Screen,
1 RJ45 Ethernet Socket,
1 Defibrillation Output,
1 Nurse Call Socket,
1 VGA Port,2 USB 1.1 Port,
1 Lithium Rechargeable Battery
Option:
Option Module:Sidesteam EtCO2 Module,MicroStream EtCO2 Module,MainStream EtCO2 Module,AG Module,C.O. Module,IBP Module,Temp Module,Nellcor SpO2 Module,Masino SpO2 Module,SunTech NIBP module
Printing:3 Channel Thermal Recorder
Mounting:Rolling Stand,Wall Mount
Battery:11.1V/4.0AH Rechargeable Lithium Battery
Other Options:External Display,Wireless Lan,Extensive Memory Card ,Analog Output(ECG or IBP)
Application:
It suitable for bedside, operation room, ICU, CCU etc.
Product Parameters
Product name | IS10 High Acuity 10.4" Multi-Parameter Modular Patient Monitor |
Place of Origin | China |
Brand Name | SINOHERO |
Standard Parameters | 3/5 Lead ECG, HR, Resp, NIBP, SpO2, PR, 2-Temp |
Optional Parameters | Sidesteam EtCO2 Module,MicroStream EtCO2 Module,MainStream EtCO2 Module,AG Module,C.O. Module, IBP Module,Temp Module,Nellcor SpO2 Module,Masino SpO2 Module,SunTech NIBP module |
Power Supply: | Electricity |
After-sale Service | Online technical support |
Material | ABS |
Quality Certification | CE ISO FDA |
Safety standard | IEC60601-1 Approved, CE marking according to MDD93/42/EEC |
Instrument classification | Class II |
Display | Sharp 10.4" LED-TFT Color Display Full Touch Screen anti-dazzling |
Resolution | 800*600 pixels |
HR Accuracy | ±1% or ±1bpm,whichever is greater |
Power Input | less than 150VA |
Power Voltage | AC 100-240V 50/60Hz |
Safety class | Category I |
Technical Specifications of iS10:
Size and Weight
-Size: 318mm×264mm×152mm
-Weight: <= 4.5kg
-Standard module slot: 2
Power supply
-Power Voltage: AC 100-240V 50/60Hz
-Input Current: 1.1~0.5V
-Safety class: Category I
Display
-iS10: 10.4" Color TFT-LCD
-Resolution: 800×600 pixels
Battery
-Type: Rechargeable Lithium battery,11.1V/4.0AH
-Operating time under the normal use and full charge: >=210minutes
Recorder (Option)
-Method: Thermal dot array
-Paper width: 50mm(1.97 in)
-Paper length: 15m
-Paper Speed: 12.5/25/50(mm/sec)
-Traces: Maximum 3 tracks
-Recording way: Real-time recording, Periodic recording, Alarm recording
Alarm
-Level: Low, medium and high
-Indication: Auditory and visual
-Patient Physiological Alarm Light color: Yellow & Red
-Equipment Technical Alarm Light color: Blue
-Supports Pitch Tone and multi-level volume
-Supports custom arrhythmia tone
Input device
-Touch screen: Standard config
-Knob: Standard config
-Mouse input: Support
-Keyboard input: Support
System Output & Extensible Interfaces
-Ethernet Network: 1 Standard RJ45 socket
-Defibrillation Output: 1 BNC connector
-Nurse Call: 1 RJ11 connector
-Video Output: 1VGA port
-USB1.1 port: 2
-SD memory card: 4Gb (Option)
-Analog Output(ECG or IBP): Option
Trend & Reviewing
-Trend: Long trend: 168h, minimum resolution is 1min
(Store when power goes off)
High resolution trend: 2h, minimum resolution is 5s
-NIBP measurement reviewing: 1000 groups
-ARR event: 128 groups of ARR event and the associated waveform
-Alarm events: 128 groups of parameter alarm events and associated parameter
waveform at the alarm moment
-Full Disclosure waveform: 24 hours for 3 waveforms(with 4Gb SD card)
Environment
-Operating temperature: 0ºC~+40ºC
-Storage temperature: -20ºC~+50ºC
-Operating humisity: 15% to 85% non condensing
-Storage humidity : 10% to 93% non condensing
-Operating atmospheric pressure: 860hPa to 1060hPa
-Storage atmospheric pressure: 500hPa to 1060hPa
Safety:
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
ECG
-Lead Mode: 3-leads ECG input
5-leads ECG input
12-leads ECG input
-Lead selection: I, II, III
I, II, III, aVR,aVL,aVF,V-
I, II, III, aVR,aVL,aVF,V1~V6(option)
-Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1),
20mm/mV(×2), 40mm/mV(×4),Auto
-RR: Monitor mode>=105dB
Surgery mode<=105dB
Diagnostic mode>=90dB
-Frequency response(-3d B):
Monitor mode 0.5~40Hz
Surgery mode 1~25Hz
Diagnostic mode 0.05~150Hz
-Input impedance: >=5.0Mohm
-ECG signal range: ±10.0mV
-Electrode offset potential: ±500mV
-Patient Leakage Current: <10uA
-Standardizing signal: 1mV±5%
-Baseline recovery: <5s after Defibrillation. (Mon or Surg mode)
-Indication of electrode separation: Every electrode(exclusive of RL)
-Protection: Breakdown Voltage 4000VAC 50/60Hz; defibrillator proof
-Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
HR
-Range: Adult 10~300bpm
Pediatric & Neonate: 10~350bpm
-Refreshing time: <=50 bpm Per2 pulses
50~120bpm per 4 pulses
>=120bpm per 6 pulses
-Resolution: 1bpm
-Accuracy: ±1% or ±1bpm,whichever is greater
ST segment
-Measurement range: -2.0mV~2.0mV
-Accuracy: -0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater
Over ±0.8mV: unspecified
-Resolution: 0.01mV
RESP
-Method: Thoracic Impedance
-Lead Selected from: I (RA-LA) or II (RA-LL); Default: I
-Gain: ×0.25, ×1, ×2, ×4
-Bandwidth: 0.25Hz to 2.0Hz (-3dB)
-Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
-Measurement Range: 0~150 rpm
-Resolution: 1rpm
-Accuracy: ±2rpm or 2% whichever is greater
-Delay of Apnea Alarm: 10s,15s,25s,30s,35s,40s,45s,50s,55s,60s
NIBP
-Way of measurement: Automatic Oscillometry
-Range of measurement:
Adult: SYS 30~270mmHg
DIA 10~220mmHg
MAP 20~235mmHg
Child: SYS 30~235mmHg
DIA 10~220mmHg
MAP 20~225mmHg
Neonate: SYS 30~135mmHg
DIA 10~100mmHg
MAP 20~125mmHg
-Cuff pressure range: 0~300mmHg
-Resolution: 1mmHg
-Pressure Accuracy: Static: ±2% or ±3mmHg,whichecer is greater
Clinical: ±5mmHg average error
Standard deviation: <=8mmHg
-Unit: mmHg, kPa
-Measurement mode: Manual, Auto, STAT
-Intervals for AUTO measurement time: 1,2,3,4,5,10,15,30,60,90 minutes;
2, 4, 8, 12 hours
-STAT mode cycle time: Keep 5 minutes, at 5 seconds interval.
-Overpressure Protection: Hardware and software double protections
-Pulse rate range: 40~240bpm
Standard SpO2(Digital)
-Measurement Range: 0~100%
-Resolution: 1%
-Accuracy: At70~100%,±2%
At0~69%, unspecified
PR
-Measurement Range: 25~255bpm
-Resolution: 1bpm
-Accuracy: ±1% or ±1bpm,whichever is greater
Nellcor-SpO2 (Option)
-Measurement Range: 0~100%
-Resolution: 1%
-Accuracy: At70~100%:±2%(Adult)
At70~100%:±3%(Neonate)
At70~100%: ±2%(Low Perfusion)
At0~69%, unspecified
PR
-Measurement Range: 20~300bpm
-Resolution: 1bpm
-Accuracy: 20bpm to 250bpm: ±3bpm
251bpm to 300bpm: unspecified
Masimo-SpO2 (Option)
-Measurement Range: 0% to 100%
-Resolution: 1%
-Accuracy: 70% to 100%: ±2%(adult/pediatric,non-motion conditions)
70% to 100%: ±3%(neonate,non-motion conditions)
70% to 100%: ±3%(motion conditions)
0% to 69%, unspecified
-Average time: 2-4s,4-6s,8s,10s,12s,14s,16s
PR
-Measurement Range: 25bpm to 240bpm
-Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
-Resolution: 1bpm
TEMP
-Max Channel: 6
-Measurement way: Thermal resistance way
-Measurement Range: 0.0ºC~50.0ºC(32ºF~122ºF)
-Accuracy: ±0.1ºC or ±1ºF(exclusive of probe)
-Resolution: 0.1ºC or 1ºF
-Unit: Celsius(ºC),Fahrenheit(ºF)
IBP
-Max Channel: 6
-Measurement way: Directly invasive pressure measurement
-Sensitivity of transducer: 5uV/V/mmHg, ±2%
-Impedance of transducer: 300 to 3000Ω
-Measurement Range: -50~+350mmHg
-Resolution: 1mmHg
-Unit: mmHg, kpa, H2O
-Accuracy:
Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer)
±4mmHg or ±4%, whichever is grater(inclusion of transducer)
Dynamic: ±4mmHg or 4%, whichever is grater
Transducer sites: Arterial Pressure (ART)
Pulmonary Artery Pressure (PA)
Left Atrium Pressure (LAP)
Right Atrium Pressure (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/P2
-Selection of measurement range:
ART:0~+350mmHg
PA:-10~+120mmHg
CVP/RAP/LAP/ICP:-10~+40mmHg
P1/P2:-50~+350mmHg
EtCO2 (Sidestream)
-Measure method: Infrared spectrum
-Measure Range: 0.0~13.1%(0~99.6mmHg)
-Resolution: 1mmHg
-Unit: %,mmHg,kpa
-Accuracy: 0% to 4.9%, ±0.3%(±2.0mmHg)
5.0%to 13.1%, <±10% of reading
-Measurement range of awRR: 3~150rpm
-Calibration: Offset calibration: auto, manual, Gain calibration
EtCO2 (Mainstream)
-Measure method: Infrared spectrum
-Warm up time: Capnogram displayed in less than 15 seconds,At an ambient
Temperature of 25ºC,full specifications within 2 minutes.
-Measure Range: 0.0~19.7%(0~150mmHg)
-Resolution: 1mmHg
-Rise time(10l/min): <=60ms
-Unit: %,mmHg,kpa
-CO2 Accuracy: 0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(at 760 mmHg,ambient temperature of 25ºC)
-awRR measurement range:0~150rpm
-awRR measurement Accuracy: ±1rpm
EtCO2 (Microstream)
-Measure method: Infrared spectrum
-Warm up time: Capnogram displayed in less than 20 seconds, At an ambient
Temperature of 25ºC,full specifications within 2 minutes.
-Measure Range: 0.0-19.7%(0-150mmHg)
-Resolution: 1mmHg
-Unit: %, mmHg, kPa
-CO2 Accuracy: 0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(At 760 mmHg,ambient temperature of 25ºC)
(When RR>80 rpm, all the range is ±12% or reading)
CO2 response time: <3S
-awRR measurement range: 2~150rpm
-awRR measurement Accuracy: ±1rpm
-Sample Flow Rate: 50ml/min ±10ml/min
Anesthetic Gas
-Measure method: Infrared spectrum
-Measure mode: Mainstream or Sidestream
-Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,ENF,SEV,DES)
-Resolution: 1%
-Unit: %
-Calibration: Room air calibration performed automatically when changing airway
adapter (<5 sec)
-Warm-up time: <10S, full accuracy within 1min
-Measurement and alarm range of AG
-Gas Range Accuracy
CO2 0-10% ±(0.3% ABS+4%REL)
N2O 0-100% ±(2% ABS+8%REL)
O2 10-100% ±(2% ABS+2%REL)
HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL)
SEV 0-8% ±(0.15% ABS+10%REL)
DES 0-18% ±(0.15% ABS+10%REL)
-awRR measurement range: 0~150rpm
-awRR measurement Accuracy: ±1rpm
-Rise time(flowing speed 10I/min) CO2<=90ms
O2<=300ms
N2O<=300ms
Hal,Iso,Enf,Sev,Des<=300ms
-Total system response time: <1seconds
C.O.
-Measurement Mode: Thermal dilution method
-Measurement Wave: Thermal dilution curve
-Measurement parameters: C.O., TB, TI, C.I.
-Measurement Range: C.O.: 0.1 L/min ~ 20 L/min
TB: 23.0 ~ 43.0ºC
TI: -1.0 ~ 27.0ºC
-Resolution: C.O.: 0.1 L/min
TB: 0.1ºC
TI: 0.1
-Accuracy: C.O.: 2% SD
-TB Alarm range: 23.0~43.0ºC, high/low limit can be adjusted continuously
Detailed Photos
Certifications
Packaging & Shipping
Physical Identity:
Size and Weight
Product size: 43.4x38.9x20.6cm, Packing size: 63x43x56cm
Net weight: 14kg, Gross weight: 17kg
Standard module slot:4
Additional module rack Slot:1
Standard Accessories:1* 10.4" LED-TFT full touch screen host, SpO2 +ECG+NIBP+2TEMP+PR+HR+RESP
1* Repetitive oxygen probe/adult/finger clip /1M*1+ blood oxygen extension cord
1* Lead wire
1* Repetitive blood pressure cuff
1* Built-in lithium battery
10* Disposable ECG electrode
1* Temperature probe
1* Blood pressure cuff
1* Power cord
1* Ground wire
Optional:
Option Module:Sidesteam EtCO2 Module,MicroStream EtCO2 Module,MainStream EtCO2 Module,AG Module,C.O. Module,IBP Module,Temp Module,Nellcor SpO2 Module,Masino SpO2 Module,SunTech NIBP module
Printing:3 Channel Thermal Recorder
Mounting:Rolling Stand,Wall Mount
Battery:11.1V/4.0AH Rechargeable Lithium Battery
Other Options:External Display,Wireless Lan,Extensive Memory Card ,Analog Output(ECG or IBP)
Company Profile
Sino-Hero (Shenzhen) Bio-Medical Electronics Co., Ltd, founded in 2003, is one of the leading manufactures for medical devices and medical accessories in China. We are firmly committed to excellence of professional service, product quality and striving for maximal mutual win-win partnership. Sino-Hero has and will continue to put on a great deal of efforts to work towards utmost success mutually with our partners. We are customer-centric and dedicated and want to and work towards being right choice to our worldwide distributors. With years of endless efforts, we have enjoyed growth and continuous success in the international market.
SINOHERO's excellent advantages for our valuable international distributors, including: - To offer the most competitive offer to our distributors, not only the best price in the market, but also the most cost-effective products with high quality and reliability - Excellent distribution opportunity to all major markets now is available, we are committed to give our valuable distributors maximal market protection and grow together - Most responsive and efficient service support to your distributors, we offer extended warranty policy on our products, you will enjoy peace of mind - More new products will be in the market and available for our distributors in the following days.
SINO-HERO business activities focus on product lines below:
1) A wide range of versatile Patient Monitors suitable for all hospital setting, including OR, ER, Recovery Room, General Patient ward
2)Monitoring Accessories maximal compatibility for all major brands (GE, Philips, Schiller, Collin, CSI, Critikon, Nihon Kohden, etc.): including, Reusable Spo2 Sensor & Ext-Cable, ECG cable, EKG cable, NIBP cuff, Air-hose, Temp probe
3) ECG machine and its accessories
4) Infusion pump and Syringe Pump system
5) Obstetrical product: Fetal Doppler, Colposcope
6) Medical Imaging Systems:Color Ultrasound Scanner, Portable Ultrasound System
7) A wide range of compatible ultrasound probes and repairable ultrasound probes.
Thank you for your trust and support, we will continue to provide you with quality productand service sinserely.
1. Who we are?Where we are from? Where we service?
We are Sino-Hero (Shenzhen) Bio-Medical Electronics Co., Ltd, founded in 2003, is one of the leading manufactures for medical devices and medical accessories in China. We are based in Shenzhen,Guangdong, China, start from 2004, WE service more than 100 country: Northern Europe(10.00%),Western Europe(10.00%),EasternAsia(10.00%),South Asia(10.00%),Southern Europe(10.00%),Southeast Asia(10.00%),Eastern Europe(10.00%),South America(10.00%),North America(10.00%),Mid East(5.00%),Africa(5.00%). There are total about 11-50 people in our office.
2.What we have?How can we guarantee quality?
We are professional in medical more than 16 Years,We have TUV CE a& ISO13485 Certifications for our products. All of our items Always a pre-production sample before mass production; All items get 100% checking before in our stock; Always final Inspection before shipment.
3.What items we could provide for you?
SINO-HERO business activities focus on product lines below: 1) A wide range of versatile Patient Monitors suitable for all hospital setting, including OR, ER, Recovery Room, General Patient ward 2)Monitoring Accessories maximal compatibility for all major brands (GE, Philips, Schiller, Collin, CSI, Critikon, Nihon Kohden, etc.): including, Reusable Spo2 Sensor & Ext-Cable, ECG cable, EKG cable, NIBP cuff, Air-hose, Temp probe 3) ECG machine and its accessories 4) Infusion pump and Syringe Pump system 5) Obstetrical product: Fetal Doppler, Colposcope 6) Medical Imaging Systems:Color Ultrasound Scanner, Portable Ultrasound System 7) A wide range of compatible ultrasound probes and repairable ultrasound probes.
4. Why should you buy from us not from other suppliers?
SINHERO's products are installed in over 50 countries, including US, UK, Germany, France, Italy, Spain, etc. and the percentage of
total sales from Europe has been growing fast.
The main competitive advantages of SINOHERO's products:
a. quality
b. functionality
c. easy maintenance and easy to operate
d. spare parts and consumables at low cost
e. on-time delivery
f. strong after sales technical support
5. What services we Can provide for you?
We could provide items with Ready to ship,we also could do OEM,ODM orders,we also welcome you to be our Brand Sinohero Agent to work together with us;
Accepted Delivery Terms: FOB,CIF,EXW,DDU,Express Delivery;
Accepted Payment Currency:USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY;
Accepted Payment Type: T/T,L/C,PayPal,Western Union,Cash,Escrow;
Language Spoken:English,Chinese,Spanish,German,French,Russian