Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit

China Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit, Find details about China Ahu, Air Handling Unit from Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit

Model NO.
SW/SL
Mounting
Ceiling or Floor Standing
Lifetime
>20 years
Certification
ISO, CE, CCC
Condition
New
Panel Material
Double Skin with Polyurethane Foam
Coil Material
Blue Hydrophilic Aluminum Fin/Copper Tubes
Filter
Primary Filter/Medium Filter/HEPA Filter etc
Optional Function
Cooling/Heating/Air Filtering/Dehumidification etc
Customzied
Yes
Trademark
SENDO or OEM
Transport Package
Plastic Film Wrapped
Specification
1000-50000m3/h For Standard AHU
Origin
China
HS Code
8415830000
Model NO.
SW/SL
Mounting
Ceiling or Floor Standing
Lifetime
>20 years
Certification
ISO, CE, CCC
Condition
New
Panel Material
Double Skin with Polyurethane Foam
Coil Material
Blue Hydrophilic Aluminum Fin/Copper Tubes
Filter
Primary Filter/Medium Filter/HEPA Filter etc
Optional Function
Cooling/Heating/Air Filtering/Dehumidification etc
Customzied
Yes
Trademark
SENDO or OEM
Transport Package
Plastic Film Wrapped
Specification
1000-50000m3/h For Standard AHU
Origin
China
HS Code
8415830000
Company Profile

SENDO is a professional manufacturer of quality air conditioning products.

Sendo could supply most products in HVAC field, such as Rooftop Packaged Unit, Split Commercial Unit, Air Cooled Water Chiller, Water Cooled Water Chiller, Chilled Water Air Handling Unit and Fan Coil Unit etc.

Sendo also supplies made-to-measure HVAC solutions. We engineer and manufacture Air Conditioner to suit the building design and application.

 
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit

Air Handling Unit & Modular Air Handling Unit
 
Air Handling Unit
Air flow rate ranging from 1,000m3/h to 50,000m3/h;
Three structure design: horizontal type, vertical type and suspended type;
Two pipe connecting mode, right-handed and left handed;
ESP can be customized.

Modular Air Handling Unit
Unitary structure design, more outstanding cold-bridge-free performance, lower air leakage and more elegant appearance.
It realizes a variety of functions: cooling, heating, humidification, dehumidification, air purification, noise elimination and so on.

 
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit

Features

High reliability
Panels are double-skin with injection of high density polyurethane. The external panel is anti-corrosion color-coated steel sheet, the internal liner is 0.5mm galvanized steel sheet.

Outstanding cold-bridge-free structure
Sendo patented cold-bridge free design. The density of polyurethane injection is 50kg/m3 panel (thermal conductivity factor K≤0.0201W/m²·K).
 
High efficient
Copper pipe and aluminum fin type heat exchanger, optimal choice of fin spacing and number of rows;
Optimal water circuits design, increased heat exchange efficiency and decreased water resistance, improving unit performance efficiency;
Yilida brand centrifugal fan as standard, Kruger brand is optional. High performance efficiency, 3-phase, class "F" insulation and IP54 protection AC motor. Belt drive, optimal selection of drive ratio, increase fan/motor assembly efficiency, easy for maintenance;
Optional Siemens inverter motor and ABB inverter;
Optional EC technology.

 
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit

Low noise design
Optimal fan selection, excellent working condition, efficient operation.
Flexible connection at air outlet, minimizes vibration transmision.
Equip with shock absorbers, decreases vibration, low noise.
Tighten cabinet, secure against noise leakage.


Specifications
Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
1.Cooling capacity is based in the following
a)Water temperature:7°C(inlet)/12°C(outlet) b)Air entering condition:27°C DB/19.5 °C WB
2.Heating capacity is based on the following:
a)Water temperature:60°C(inlet) /50°C(outlet) b)Air entering condition:21 °C DB
 
Workshop

Clean Room Modular Ahu/Ceiling Mounted Heat Recovery Air Handling Unit
Sendo contribution to combat rising energy costs and global warming is to design innovative, efficient and dependable AC products, while providing best comfort and air quality. We are optimistic about the response that we expect to get from our potential customers because we strive to ensure that our customers get the quality products when they approach us and we are determined to ensure that our customers can obtain various benefits when they buy Sendo Air Conditioners.

Get in touch with us and book a Factory Tour! Sincerely welcome to visit our factory at your convenience.